Rest | Rest Lever |
|
Square Nut
Figure 13. Rest installation.
Dust Collection
DO NOT operate the Model G0489 with a | |
dust collection system that has been previ- | |
ously used for wood dust collection or other | |
combustible material. Hot metal sparks and | |
fragments could cause material to ignite! DO | |
NOT attach to plastic fittings or dust collec- | |
tion system not rated specifically for metal | |
dust collection! | |
The Model G0489 comes with a 4" dust port | |
ready to attach to your metal dust collection sys- | |
tem. Your dust collection system is unique so we | |
cannot give you specific instructions to cover all | |
the possible set up options. | |
To connect a dust collection hose: | |
1. | Fit your dust hose over the dust port and |
| secure in place with a hose clamp. |
Test Run
Once the assembly is complete, test run your machine to make sure it runs properly.
If, during the test run, you cannot easily locate the source of an unusual noise or vibration, stop using the machine immediately.
If you cannot remedy a problem, contact our Tech Support at (570)
To test run the machine:
1.Connect the machine to the power source.
2.Make sure you have read the safety instruc- tions at the beginning of the manual and that the machine is setup properly.
3.Make sure all tools and objects used during set up are cleared away from the machine.
4.Turn the machine ON.
5.Listen to and watch for abnormal noises or actions. The machine should run smoothly with little or no vibration or rubbing noises.
G0489 Metalworking Sander |