2.Double insulated tools may be used in either of the 120 volt outlets shown in the pre- ceding illustration. (See Figure B.)

Extension Cords

1.Grounded tools require a three wire extension cord. Double Insulated tools can use either a two or three wire extension cord.

2.As the distance from the supply outlet increases, you must use a heavier gauge exten- sion cord. Using extension cords with inadequately sized wire causes a serious drop in voltage, resulting in loss of power and possible tool damage.

(See Figure C, next page.)

3.The smaller the gauge number of the wire, the greater the capacity of the cord. For example, a 14 gauge cord can carry a higher current than a 16 gauge cord.

(See Figure C.)

4.When using more than one extension cord to make up the total length, make sure each cord contains at least the minimum wire size required. (See Figure C.)

5.If you are using one extension cord for more than one tool, add the nameplate amperes and use the sum to determine the required minimum cord size. (See Figure C.)

6.If you are using an extension cord outdoors, make sure it is marked with the suffix “W- A” (“W” in Canada) to indicate it is acceptable for outdoor use.

7.Make sure your extension cord is properly wired and in good electrical condition. Al- ways replace a damaged extension cord or have it repaired by a qualified electrician before using it.

8.Protect your extension cords from sharp objects, excessive heat, and damp or wet areas.

RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS*

(120 or 240 VOLT)

NAMEPLATE

 

EXTENSION CORD LENGTH

 

AMPERES

 

 

 

 

 

 

 

(at full load)

25 Feet

50 Feet

75 Feet

100 Feet

150 Feet

0 – 2.0

18

18

18

18

16

2.1

– 3.4

18

18

18

16

14

3.5

– 5.0

18

18

16

14

12

5.1

– 7.0

18

16

14

12

12

7.1 – 12.0

18

14

12

10

-

12.1

– 16.0

14

12

10

-

-

16.1

– 20.0

12

10

-

-

-

FIGURE C

* Based on limiting the line voltage drop to five volts at 150% of the rated amperes.

SKU 92158

For technical questions, please call 1-800-444-3353.

Page

Image 7
Contents Bandfile 1/2 Inch Belt Sander For technical questions or replacement parts, please callSave This Manual SpecificationsGeneral Safety Rules Electrical SafetyPersonal Safety Specific Safety Rules for This Product ServiceTool Use and Care SKU For technical questions, please call Double Insulated Tools Tools With Two Prong Plugs Grounded Tools Tools With Three Prong PlugsFeet Extension CordsAssembly Instructions Installing the Sanding Belt SymbologyUnpacking Operation Operating Instructions ControlsDo not use damaged equipment INSPECTION, MAINTENANCE, and CleaningPart Description Parts ListAssembly Drawing Record Product’s Serial Number Here