Sanyo KMS0712, CM3212 service manual 230V CM3622 / KMS1812

Page 14

230V

CM3622 / KMS1812

Rating Capacity: 18,000 BTU/H

 

 

Air Flow Rate: 440 CFM

 

Evaporator

 

 

 

 

Condenser

 

 

 

Ent. Temp.

°F/(°C)

 

 

 

Ambient Temp.

°F/(°C)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WB

 

DB

 

 

75

 

85

 

95

105

 

115

 

 

 

(23.9)

 

(29.4)

(35.0)

(40.6)

 

(46.1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TC

 

17,820

 

17,010

16,200

15,280

 

14,040

 

 

 

kW

 

1.30

 

1.41

 

1.54

1.67

 

1.83

59

 

72 (22.2)

SHC

 

12,350

 

11,900

11,460

10,970

 

10,340

(15.0)

 

76 (24.4)

SHC

 

13,720

 

13,270

12,830

12,350

 

11,710

 

 

80 (26.7)

SHC

 

15,150

 

14,700

14,260

13,780

 

13,140

 

 

84 (28.9)

SHC

 

16,520

 

16,070

15,630

15,150

 

14,040

 

 

88 (31.1)

SHC

 

17,820

 

17,010

16,200

15,280

 

14,040

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TC

 

18,430

 

17,860

17,150

16,220

 

14,940

 

 

 

kW

 

1.31

 

1.43

 

1.56

1.70

 

1.87

63

 

72 (22.2)

SHC

 

10,550

 

10,260

 

9,910

9,450

 

8,840

(17.2)

 

76 (24.4)

SHC

 

11,920

 

11,630

11,280

10,820

 

10,210

 

 

80 (26.7)

SHC

 

13,350

 

13,060

12,710

12,250

 

11,640

 

 

84 (28.9)

SHC

 

14,720

 

14,430

14,080

13,620

 

13,010

 

 

88 (31.1)

SHC

 

16,090

 

15,800

15,450

14,990

 

14,380

 

 

 

TC

 

18,940

 

18,630

*18,000

17,010

 

15,840

 

 

 

kW

 

1.32

 

1.45

 

1.58

1.72

 

1.91

67

 

72 (22.2)

SHC

 

8,680

 

8,540

 

8,250

7,800

 

7,290

(19.4)

 

76 (24.4)

SHC

 

10,050

 

9,910

 

9,620

9,180

 

8,660

 

 

80 (26.7)

SHC

 

11,480

 

11,340

11,050

10,610

 

10,100

 

 

84 (28.9)

SHC

 

12,850

 

12,710

12,420

11,980

 

11,470

 

 

88 (31.1)

SHC

 

14,220

 

14,080

13,790

13,350

 

12,840

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TC

 

19,530

 

19,210

18,720

17,870

 

16,830

 

 

 

kW

 

1.33

 

1.46

 

1.60

1.77

 

1.95

71

 

72 (22.2)

SHC

 

6,760

 

6,630

 

6,430

6,080

 

5,660

(21.7)

 

76 (24.4)

SHC

 

8,130

 

8,000

 

7,800

7,450

 

7,040

 

 

80 (26.7)

SHC

 

9,570

 

9,430

 

9,230

8,880

 

8,470

 

 

84 (28.9)

SHC

 

10,940

 

10,800

10,600

10,260

 

9,840

 

 

88 (31.1)

SHC

 

12,310

 

12,170

11,970

11,630

 

11,210

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TC

 

19,910

 

19,690

19,260

18,580

 

17,820

 

 

 

kW

 

1.36

 

1.49

 

1.63

1.81

 

2.00

75

 

76 (24.4)

SHC

 

6,210

 

6,130

 

5,970

5,720

 

5,440

(23.9)

 

80 (26.7)

SHC

 

7,640

 

7,560

 

7,400

7,150

 

6,880

 

 

84 (28.9)

SHC

 

9,010

 

8,930

 

8,770

8,520

 

8,250

 

 

88 (31.1)

SHC

 

10,390

 

10,300

10,140

9,890

 

9,620

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TC: Total Cooling Capacity (BTU/H)

 

 

 

 

 

 

 

SHC: Sensible Heat Capacity (BTU/H)

 

 

 

 

 

 

 

kW:

Compressor Input (kW)

 

Remarks: Rating conditions (* mark) are: Outside ambient temperature 95°F DB

Indoor unit entering air temperature 80°F DB/67°F WB

9WM – 700699

Image 14
Contents Split System AIR Conditioner Page CM3212 / KMS0712⋅2+KMS1812 Basic Information …In a Room For safe installation and trouble-free operation, you must…In a Ceiling or Wall …In Moist or Uneven LocationsTable of Contents Operating Range CM3212 / KMS0712⋅2+KMS1812Specifications Unit SpecificationsApplicable Indoor Unit KMS1812 Wall-mounted Cooling 18,000 / 17,600 440 Dimensional Data Outdoor Unit CM3212Indoor Unit KMS0712 Indoor Unit KMS1812Cooling Capacity 230V CM3622 / KMS0712⋅1208V CM3622 / KMS0712⋅1 230V CM3622 / KMS1812 208V CM3622 / KMS1812 Refrigerant Flow Diagram Outdoor UnitCM3212 / KMS1812⋅1 Electrical Characteristics CM3212 / KMS0712⋅1Electrical Data CM3212 / KMS7012⋅2CM3212 / KMS0712+KMS1812 CM3212 / KMS7012⋅2+KMS1812To avoid electrical shock hazard, be sure to Controller From Outdoor Unit H406/12M