Sanyo CH0951, CH1251 installation instructions Installation Instructions, Contents

Page 1

INSTALLATION INSTRUCTIONS

– Split System Air Conditioner – COOL / DRY/HEAT Model

Contents

 

 

 

Page

IMPORTANT!

 

Please Read Before Starting

2

1.

GENERAL

3

 

1-1.

Tools Required for Installation (not supplied)

 

1-2.

Accessories Supplied with Unit

 

 

1-3.

Optional Copper Tubing Kit

 

 

1-4.

Type of Copper Tube and Insulation Material

 

1-5.

Field Wiring

 

 

1-6.

Additional Materials Required for Installation

2.

INSTALLATION SITE SELECTION

4

 

2-1.

Indoor Unit

 

 

2-2.

Outdoor Unit

 

3. HOW TO INSTALL THE INDOOR UNIT

6

 

3-1.

Remove the Rear Panel from the Unit

 

 

3-2.

Make a Hole

 

 

3-3.

Install the Rear Panel on the Wall

 

 

3-4.

Remove the Grille to Install the Indoor Unit

 

3-5.

Shape the Indoor Side Tubing

 

 

3-6.

Wiring Instructions

 

 

3-7.

Recommended Wire Length and Diameter

 

3-8.

Wiring Instructions for Inter-unit Connections

 

3-9.

Mounting

 

 

3-10.

Drain Hose

 

4. HOW TO INSTALL THE OUTDOOR UNIT

15

 

4-1.

Wiring Instructions for the Outdoor Unit

 

5.

REFRIGERANT TUBING

16

 

5-1.

Use of the Flaring Method

 

 

5-2.

Flaring Procedure with a Flare Tool

 

 

5-3.

Caution before Connecting Tubes Tightly

 

5-4.

Connecting Tubing between Indoor and

 

 

 

Outdoor Units

 

 

5-5.

Insulation of Refrigerant Tubing

 

 

5-6.

Taping the Tubes

 

Model Combinations

Combine indoor and outdoor units only as listed below.

Indoor Units

Outdoor Units

KHS0951CH0951

KHS1251CH1251

Power Source:

60 Hz, single-phase, 115 V

KHS1852CH1852

Power Source:

60 Hz, single-phase, 230/208 V

5-7. Finishing the Installation

 

6. AIR PURGING

18

Air Purging with a Vacuum Pump (for Test Run)

Basic Function of the Service Valves

Pump Down

7.REMOTE CONTROL UNIT INSTALLATION

POSITION

22

7-1. Mounting on a Wall

 

IMPORTANT

Power source for CH0951 and CH1251 is 60 Hz, single-phase 115 V.

 

In Canada

SANYO FISHER COMPANY

SANYO Canada Inc.

A DIVISION OF SANYO NORTH AMERICA CORPORATION

300 Applewood Crescent, Concord

21605 Plummer Street

Ontario, L4K 5C7, Canada

85264189615003 © SANYO 2002 Chatsworth, CA 91311 U.S.A.

 

 

W

Image 1
Contents Contents Installation InstructionsWhen Installing… When TransportingCase of Improper Installation When WiringGeneral Additional Materials Required for Installation Installation Site SelectionSolid base must not cover Outdoor UnitHole of the bottom plate Case of right-rear KHS1852Remove the Rear Panel from the Unit Make a HoleIf Wooden Wall Install the Rear Panel on the WallIf Block, Brick, Concrete or Similar Type Wall How to remove the grille Remove the Grille to Install the Indoor UnitHow to replace the grille Shape the Indoor Side Tubing Wiring Instructions General precautions on wiringNever fix the wiring by any Recommended Wire Length and DiameterIs fully seated on the rear PanelKHS0951, KHS1251 KHS1852 For Outdoor Unit For solid core wiring or F-cable How to connect wiring to the terminal For Indoor UnitFor stranded wiring Right-side tubing MountingDrain Hose To unmount indoor unitRisk of Electric Shock Examples of Incorrect Wiring How to Install the Outdoor UnitWiring Instructions for the Outdoor Unit ProblemRefrigerant Tubing Flaring Procedure with a Flare ToolUse of the Flaring Method DeburringFinishing the Installation Connecting Tubing between Indoor and Outdoor UnitsInsulation of Refrigerant Tubing After a tube has been insulatedAir Purging Hex wrench before Be sure to completely insertAttempting to turn the valve How to Test Run the Air Conditioner Pump Down Basic Function of the Service ValvesRing Valve cap Stem When using the remote control unit Remote Control Unit Installation PositionWhen mounting the remote control unit to prevent theft Mounting on a Wall