readings are taken, the battery should be charged five minutes to stimulate mixing. (Refer to battery manufacturer’s instructions regarding removal of vent caps while charging battery).

ELECTROLYTE CAUTION

Battery electrolyte is SULFURIC ACID. It can eat holes in clothes and skin. Flush spills with water.

STATE OF CHARGE CHECK

By Specific Gravity (open vent battery only)

Sample, measure and return the electrolyte from each cell with a hydrometer.

1.The specific gravity should be at least 1.230 in all cells. If not, charge the battery. If charging the battery does not bring the specific gravity up to 1.230, then the battery should be replaced.

2.The specific gravity readings should not vary more than 50 points (.050) between all cells. If the difference is greater, replace the battery.

By Open Circuit Voltage (any lead-acid battery)

Measure the open circuit (no load) stabilized voltage. A stabilized battery has no “surface charge”, which means that the electro- lyte has had a chance to remix and shed gas bubbles after cur- rent flow has stopped.

Open Circuit Volts

12.6

12.4

12.2

12.0

 

 

 

 

 

% of Charge

100

75

50

25

 

 

 

 

 

If the measured voltage is less than 12.4 volts, first recharge the battery. With a low % of charge, performance will be reduced and any load test results may be invalid.

LOAD TEST

A battery must have the capability to crank an engine while main- taining enough voltage to power the ignition. To give consistent results, these tests require that a battery be at least 75% charged and must not have been heavily used within the last 10 minutes.

The standard battery performance test is based on battery rat- ings provided by the manufacturer. If the test load amperage is known, use it, otherwise use one of the following:

1.Cold Cranking Amperes at 0°F. (CCA) - When using CCA, divide the given value by 2 to obtain the load. FOR example, 1000 CCA divided by 2 equals a 500 amperes test load.

2.Ampere Hour Rating (Ah) - If only the Ampere Hour rating is known, multiply the value by 3 to obtain the load. For example, a 200 Ah battery times 3 equals a 600 amperes load.

3.BATTERY WATTS - When only the battery rating in watts is known then use Table 1 (below) as a guide to determine what battery load or cranking amps would be normal. FOR EXAMPLE: A battery load or cranking amps for a battery rated at 2400 watts would be 125 to 200 amps.

TABLE 1

 

 

 

Battery Load or

 

Engine

Cubic

Cubic

Cranking Amp

Watt

Size

Inches

Centimeters

Rating

 

 

 

 

 

 

Small

100 to 200

1600 to 2400

100-150 Amps

1200 to 1800

 

 

 

 

 

Medium

200 to 350

2400 to 5600

125-200 Amps

1500 to 2400

 

 

 

 

 

Large

350 to 500

5600 to 8000

175-300 Amps

2100 to 3600

Ratings can be found on the battery, in the vehicle manual or in a replacement battery application guide. In the battery performance load test, the rated amperage is drawn from the battery for 15 seconds while watching the battery voltage. At 70°F and higher, a good battery will maintain an output of 9.6 volts or more during the load testing period (4.8 volts for 6 volt battery). When a bat- tery is cooler than 70°F, the output voltage requirement is re- duced to give equivalent test conclusions per the following (Table 2):

Table 2

ELECTROLYTE TEMP

MINIMUM

 

–°F–

–°C–

LOADED VOLTS

 

70

21

9.6

 

60

16

9.5

 

50

10

9.4

 

40

4

9.3

 

30

-1

9.1

 

20

-7

8.9

 

10

-12

.7

 

0

-18

8.5

NOTE: DIVIDE MINIMUM TEST VOLTAGE IN HALF FOR 6 VOLT BATTERIES.

LOAD TEST CAUTION

If the amperes display goes out while loading a battery, the voltage has fallen below 4.0 volts. TURN THE LOAD OFF IM-

MEDIATELY.

The battery could become overheated. If a battery smokes while being loaded, immediately discontinue using it. It is not safe.

Zero Amp Meter. Then Place AMP PROBE around either ana- lyzer cable.

BLACK

RED

BATTERY

CHASSIS

Figure 1

Connection for LOAD TEST

1.Have the Load knob turned to “OFF” before connecting.

2.Connect analyzer Battery Clamps to battery terminals, Red to POS (+), Black to NEG (-) the cables can be reverse. Wiggle clamps to be sure that the clamp jaws make good contact with battery terminals.

3.Set the Volts Selector to “Battery Volts”. The analyzer should show battery voltage over 12.4V. (6.2V)

4

Image 4
Contents Electric Corporation MT. PROSPECT, IL Outstanding Features of the Charging System Analyzer are Analyzer Features Battery CablesMust be Dealt with Very Carefully Contact Physician ImmediatelyTimer Beeper and Time OUT Lamp Battery CautionBattery Testing Amps DisplayElectrolyte Caution State of Charge CheckLoad Test Electrolyte Temp Minimum Loaded Volts Load Test CautionTypical Starter Cranking Draw Diagnostic Test ProcedureEngine Size Solenoid Control Switch Test Voltage Amps Likely CauseINSULATED-POS Circuit Test Volt Cranking Circuit Typical Voltage Drop MaximumsIf Battery has LOW Charge RUN Engine with Accessories OFFBattery Goes Above Alternator System TestsRegulator Ground Test External Regulator CautionLoad Requirement Test Full Fielding Amperage TestSeries Parallel Switch Battery Load TestTest Procedures Steps for External Regulator Type ALTERNA- TORTest Conclusions Test ProcedureAlternator Output Current Test Transformer Rectifier Troubleshooting Series Parallel CircuitAnalyzer Care Unusual Analyzer OperationLimited Warranty