using the built-in BATTERY tester
OVERVIEW
This battery charger has a
TESTING SEQUENCE
There are four basic steps required to use the
1.Connect the charger battery clamps to the battery. Be sure to follow all of the precautions listed under “OPERATING INSTRUCTIONS”.
2.Connectthechargerpowercordtoa120V AC
“OPERATING INSTRUCTIONS”.
3.If necessary, press the Battery Type button until the correct type is indicated.
4.Read the voltage on the digital display or press the digital display button to set the tester to Battery % and read the battery percent.
TESTER AND CHARGER
When first turned on, the
POWER-UP IDLE TIME LIMIT
If no button is pressed within 15 minutes after the
TESTER WITHOUT TIME LIMIT
If either the DIGITAL Display or Bat- tery Type button is pressed within the first 15 minutes after the
TESTING AFTER CHARGING
After the
TESTER STATUS LEDs
When the
•The CHARGED (green) LED will light if a charged battery is tested.
•The CHARGING (yellow) LED does not light in the battery test mode.
•TheconnectedLEDlightsifaproperly connected battery is detected.
•When the tester digital display is set to voltage, the CHARGED and CHARG-
ING LEDs won't light (it could be testing a battery or an alternator).
INITIAL PERCENT CALCULATION When a battery % is calculated for the first time after connecting a battery, the digital display will show three dashes
NOTES FOR TESTING BATTERY % A recently charged battery could have a temporarily high voltage due to what is known as “surface charge”. The volt- age of such a battery will gradually drop during the period immediately after the charging system is disengaged. Consequently, the tester could display inconsistent values for such a battery. For a more accurate reading, the surface