Sanyo C1251, C1852, CL0951, CL1852 installation instructions Installation Instructions, Contents

Page 1

INSTALLATION INSTRUCTIONS

– Split System Air Conditioner –

COOL /DRY Model

Contents

 

 

 

Page

IMPORTANT!

 

Please Read Before Starting

2

1.

GENERAL

3

 

1-1.

Tools Required for Installation (not supplied)

 

1-2.

Accessories Supplied with Unit

 

 

1-3.

Optional Copper Tubing Kit

 

 

1-4.

Type of Copper Tube and Insulation Material

 

1-5.

Field Wiring

 

 

1-6.

Additional Materials Required for Installation

2.

INSTALLATION SITE SELECTION

4

 

2-1.

Indoor Unit

 

 

2-2.

Outdoor Unit

 

 

2-3.

Baffle Plate for the Outdoor Unit

 

3. HOW TO INSTALL THE INDOOR UNIT

6

 

3-1.

Remove the Rear Panel from the Unit

 

 

3-2.

Make a Hole

 

 

3-3.

Install the Rear Panel on the Wall

 

 

3-4.

Remove the Grille to Install the Indoor Unit

 

3-5.

Shape the Indoor Side Tubing

 

 

3-6.

Wiring Instructions

 

 

3-7.

Recommended Wire Length and Diameter

 

3-8.

Wiring Instructions for Inter-unit Connections

 

3-9.

Mounting

 

 

3-10.

Drain Hose

 

4. HOW TO INSTALL THE OUTDOOR UNIT

15

 

4-1.

Wiring Instructions for the Outdoor Unit

 

5.

REFRIGERANT TUBING

16

 

5-1.

Use of the Flaring Method

 

 

5-2.

Flaring Procedure with a Flare Tool

 

 

5-3.

Caution before Connecting Tubes Tightly

 

5-4.

Connecting Tubing between Indoor and

 

 

 

Outdoor Units

 

 

5-5.

Insulation of Refrigerant Tubing

 

 

5-6.

Taping the Tubes

 

Model Combinations

Combine indoor and outdoor units only as listed below.

Indoor Units

Outdoor Units

KS0951

 

 

C0951

 

 

 

 

 

CL0951

 

 

 

KS1251

 

 

C1251

 

 

 

 

 

CL1251

Power Source:

 

60 Hz, single-phase, 115 V

 

KS1852

 

C1852

 

 

 

 

 

CL1852

Power Source:

 

60 Hz, single-phase, 230/208 V

 

5-7. Finishing the Installation

6. AIR PURGING

18

Air Purging with a Vacuum Pump (for Test Run)

Basic Function of the Service Valves

Pump Down

7.REMOTE CONTROL UNIT INSTALLATION

POSITION

22

7-1. Mounting on a Wall

 

IMPORTANT

Power source for C0951, CL0951, C1251 and CL1251 is 60 Hz, single-phase 115V.

 

In Canada

SANYO FISHER COMPANY

SANYO Canada Inc.

A DIVISION OF SANYO NORTH AMERICA CORPORATION

300 Applewood Crescent, Concord

21605 Plummer Street

Ontario, L4K 5C7, Canada

85264189593004 © SANYO 2002 Chatsworth, CA 91311 U.S.A.

 

 

W

Image 1
Contents Contents Installation InstructionsWhen Installing… When TransportingCase of Improper Installation When WiringGeneral Additional Materials Required for Installation Installation Site SelectionBaffle Plate for the Outdoor Unit CL⋅⋅ models only Outdoor UnitCase of right-rear KS1852Remove the Rear Panel from the Unit Make a HoleIf Wooden Wall Install the Rear Panel on the WallIf Block, Brick, Concrete or Similar Type Wall How to remove the grille Remove the Grille to Install the Indoor UnitHow to replace the grille Shape the Indoor Side Tubing Wiring Instructions General precautions on wiringWire from the outdoor unit to the indoor unit Recommended Wire Length and DiameterEach wire must be firmly connected No wire should be allowed to touch refrigerantKS0951, KS1251 KS1852 For Outdoor Unit For solid core wiring or F-cable How to connect wiring to the terminal For Indoor UnitFor stranded wiring Right-side tubing MountingDrain Hose To unmount indoor unitRisk of Electric Shock Examples of Incorrect Wiring How to Install the Outdoor UnitWiring Instructions for the Outdoor Unit ProblemRefrigerant Tubing Flaring Procedure with a Flare ToolUse of the Flaring Method DeburringFinishing the Installation Connecting Tubing between Indoor and Outdoor UnitsInsulation of Refrigerant Tubing After a tube has been insulatedAir Purging Hex wrench before Be sure to completely insertAttempting to turn the valve How to Test Run the Air Conditioner Pump Down Basic Function of the Service ValvesRing Valve cap Stem When using the remote control unit Remote Control Unit Installation PositionWhen mounting the remote control unit to prevent theft Mounting on a Wall
Related manuals
Manual 45 pages 15.8 Kb

C0951, CL1251, CL1852, CL0951, C1251 specifications

The Sanyo C1251, CL0951, C1852, C0951, and CL1852 models represent a collection of versatile and reliable audio and visual components that cater to varied consumer demands. Each model showcases Sanyo's commitment to innovation and quality, featuring a range of technologies that enhance functionality and user experience.

The Sanyo C1251 is renowned for its compact design, making it an ideal choice for users with limited space. It incorporates advanced digital processing technology, which ensures that audio output is crisp and clear. This model is especially beneficial for smaller settings, where sound clarity and power are essential.

The CL0951 stands out with its superior connectivity options, enabling seamless integration with various devices. This model supports Bluetooth and NFC technologies, providing users with the ability to connect their smartphones easily. With built-in advanced equalization settings, users can tailor the audio output to their preferences, ensuring an optimal listening experience.

Sanyo's C1852 model is focused on delivering high-performance sound. It features a powerful amplification system, allowing it to produce rich and deep audio suitable for larger environments. This model is ideal for both casual and serious listeners who demand high fidelity and dynamic soundscapes.

The C0951 is designed for versatility, equipped with features that make it suitable for both home and office use. Its sleek design complements modern interiors, and it comes with various preset audio modes. Additionally, it offers a USB port for direct playback from flash drives, enhancing its usability.

Finally, the CL1852 serves as a flagship model in terms of multimedia capabilities. It combines high-definition video output with powerful audio performance, making it an excellent option for presentations and entertainment. The inclusion of smart features such as voice control and remote operation enhances user convenience, making it a sophisticated choice for tech-savvy consumers.

In summary, Sanyo's C1251, CL0951, C1852, C0951, and CL1852 models collectively encompass a range of features and technologies tailored to meet diverse needs. From connectivity options and sound quality to multimedia capabilities and user-centric designs, these models reflect Sanyo's dedication to providing top-notch audio and visual experiences for consumers.