IMPORTANT!

Please Read Before Starting

This air conditioning system meets strict safety and operating standards. As the installer or service person, it is an important part of your job to install or service the system so it operates safely and efficiently.

For safe installation and trouble-free operation, you must:

Carefully read this instruction booklet before beginning.

Follow each installation or repair step exactly as shown.

Observe all local, state, and national electrical codes.

Pay close attention to all warning and caution notices given in this manual.

When Transporting

Be careful when picking up and moving the indoor and out- door units. Get a partner to help, and bend your knees when lifting to reduce strain on your back. Sharp edges or thin alu- minum fins on the air conditioner can cut your fingers.

When Installing…

…In a Ceiling or Wall

Make sure the ceiling/wall is strong enough to hold the unit’s weight. It may be necessary to construct a strong wood or metal frame to provide added support.

WARNING

CAUTION

This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death.

This symbol refers to a hazard or unsafe practice which can result in personal injury or product or property damage.

…In a Room

Properly insulate any tubing run inside a room to prevent “sweating” that can cause dripping and water damage to walls and floors.

…In Moist or Uneven Locations

Use a raised concrete pad or concrete blocks to provide a solid, level foundation for the outdoor unit. This prevents water damage and abnormal vibration.

If Necessary, Get Help

These instructions are all you need for most installation sites and maintenance conditions. If you require help for a special problem, contact our sales/service outlet or your certified dealer for additional instructions.

In Case of Improper Installation

The manufacturer shall in no way be responsible for improp- er installation or maintenance service, including failure to follow the instructions in this document.

SPECIAL PRECAUTIONS

WARNING

When Wiring

ELECTRICAL SHOCK CAN CAUSE SEVERE PERSONAL INJURY OR DEATH. ONLY A QUALIFIED, EXPERIENCED ELECTRICIAN SHOULD ATTEMPT TO WIRE THIS SYSTEM.

Do not supply power to the unit until all wiring and tubing are completed or reconnected and checked.

Highly dangerous electrical voltages are used in this system. Carefully refer to the wiring diagram and these instructions when wiring. Improper connections and inadequate grounding can cause accidental injury or death.

Ground the unit following local electrical codes.

Connect all wiring tightly. Loose wiring may cause over- heating at connection points and a possible fire hazard.

…In an Area with High Winds

Securely anchor the outdoor unit down with bolts and a metal frame. Provide a suitable air baffle.

…In a Snowy Area (for Heat Pump-type Systems)

Install the outdoor unit on a raised platform that is higher than drifting snow. Provide snow vents.

When Connecting Refrigerant Tubing

Use the flare method for connecting tubing.

Apply refrigerant lubricant to the matching surfaces of the flare and union tubes before connecting them, then tighten the nut with a torque wrench for a leak-free connection.

Check carefully for leaks before starting the test run.

When Servicing

Turn the power OFF at the main power box (mains) before opening the unit to check or repair electrical parts and wiring.

Keep your fingers and clothing away from any moving parts.

Clean up the site after you finish, remembering to check that no metal scraps or bits of wiring have been left inside the unit being serviced.

2

Image 2
Contents Installation Instructions ContentsCase of Improper Installation When TransportingWhen Installing… When WiringGeneral Installation Site Selection Additional Materials Required for InstallationOutdoor Unit Baffle Plate for the Outdoor Unit CL⋅⋅ models onlyRemove the Rear Panel from the Unit KS1852Case of right-rear Make a HoleIf Block, Brick, Concrete or Similar Type Wall Install the Rear Panel on the WallIf Wooden Wall How to replace the grille Remove the Grille to Install the Indoor UnitHow to remove the grille Wiring Instructions General precautions on wiring Shape the Indoor Side TubingEach wire must be firmly connected Recommended Wire Length and DiameterWire from the outdoor unit to the indoor unit No wire should be allowed to touch refrigerantKS0951, KS1251 KS1852 For stranded wiring How to connect wiring to the terminal For Indoor UnitFor Outdoor Unit For solid core wiring or F-cable Mounting Right-side tubingRisk of Electric Shock To unmount indoor unitDrain Hose Wiring Instructions for the Outdoor Unit How to Install the Outdoor UnitExamples of Incorrect Wiring ProblemUse of the Flaring Method Flaring Procedure with a Flare ToolRefrigerant Tubing DeburringInsulation of Refrigerant Tubing Connecting Tubing between Indoor and Outdoor UnitsFinishing the Installation After a tube has been insulatedAir Purging Attempting to turn the valve Be sure to completely insertHex wrench before How to Test Run the Air Conditioner Ring Valve cap Stem Basic Function of the Service ValvesPump Down When mounting the remote control unit to prevent theft Remote Control Unit Installation PositionWhen using the remote control unit Mounting on a Wall
Related manuals
Manual 45 pages 15.8 Kb

C0951, CL1251, CL1852, CL0951, C1251 specifications

The Sanyo C1251, CL0951, C1852, C0951, and CL1852 models represent a collection of versatile and reliable audio and visual components that cater to varied consumer demands. Each model showcases Sanyo's commitment to innovation and quality, featuring a range of technologies that enhance functionality and user experience.

The Sanyo C1251 is renowned for its compact design, making it an ideal choice for users with limited space. It incorporates advanced digital processing technology, which ensures that audio output is crisp and clear. This model is especially beneficial for smaller settings, where sound clarity and power are essential.

The CL0951 stands out with its superior connectivity options, enabling seamless integration with various devices. This model supports Bluetooth and NFC technologies, providing users with the ability to connect their smartphones easily. With built-in advanced equalization settings, users can tailor the audio output to their preferences, ensuring an optimal listening experience.

Sanyo's C1852 model is focused on delivering high-performance sound. It features a powerful amplification system, allowing it to produce rich and deep audio suitable for larger environments. This model is ideal for both casual and serious listeners who demand high fidelity and dynamic soundscapes.

The C0951 is designed for versatility, equipped with features that make it suitable for both home and office use. Its sleek design complements modern interiors, and it comes with various preset audio modes. Additionally, it offers a USB port for direct playback from flash drives, enhancing its usability.

Finally, the CL1852 serves as a flagship model in terms of multimedia capabilities. It combines high-definition video output with powerful audio performance, making it an excellent option for presentations and entertainment. The inclusion of smart features such as voice control and remote operation enhances user convenience, making it a sophisticated choice for tech-savvy consumers.

In summary, Sanyo's C1251, CL0951, C1852, C0951, and CL1852 models collectively encompass a range of features and technologies tailored to meet diverse needs. From connectivity options and sound quality to multimedia capabilities and user-centric designs, these models reflect Sanyo's dedication to providing top-notch audio and visual experiences for consumers.