Sanyo C1872, C2472, CL2472, CL1872 service manual Electric Wiring Diagrams, Indoor Unit KS1872 KS2472

Page 33

6-2. Electric Wiring Diagrams

Indoor Unit KS1872 KS2472

EVAPORATOR

GRN/YEL

 

 

 

 

To avoid electrical shock hazard, be sure to WARNING disconnect power before checking, servicing

and/or cleaning any electrical parts.

TERMINAL BASE

UNIT

RED

3

OUTDOOR

BLK

1

 

WHT

2

 

 

 

TO

CONNECTOR

 

 

1

1

 

RED

 

 

2

2

 

PNK

FLAP

3

3

 

BLU

 

 

4

4

 

BRN

 

 

5

5

 

YEL

FLAP MOTOR

 

 

AC1 AC2 SI

 

 

 

 

1

1

 

 

 

 

 

 

 

 

2

2

1

1

 

 

 

 

3

3

2

2

FLAP

4

4

3

3

5P (WHT) LAMP

5

5

4

4

10P(WHT)

6

6

5

5

 

 

7

7

 

 

 

 

 

 

 

 

8

8

 

 

 

 

9

9

 

 

 

 

10

10

CONTROLLER

RED

 

1

1

ASSY

WHT

 

2

2

WHT

 

3

3

 

WHT

 

4

4

LAMP

WHT

 

5

5

WHT

 

6

6

 

WHT

 

7

7

IND

WHT

 

8

8

WHT

 

9

9

 

WHT

 

10

10

 

ROOM THERMISTOR

RED

BLK

FMWHT

YEL

BLU

FAN MOTOR

1

1

 

 

 

 

 

 

 

 

 

1

1

 

ROOM/COIL

2

2

2

2

 

 

 

 

 

3

3

DCM

4P(WHT)

 

 

3

3

 

 

 

 

 

 

 

 

4

4

4

4

6P(BLU)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

5

 

 

 

 

 

 

 

 

 

 

 

 

6

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ION

 

 

1

1

 

 

 

 

 

 

 

 

2

2

 

 

 

3P (WHT)

 

 

 

 

 

 

 

 

 

 

3

3

 

 

 

 

 

HA

 

 

 

 

 

 

 

 

 

JEM-A

 

 

 

 

 

 

 

 

 

4P (WHT)

 

 

 

 

 

1

2

 

3

 

4

 

 

ION

TERMINAL

BLK

BLK

BLK

BLK

COIL THERMISTOR

 

 

BLK

BLK

RED

WHT

BLK

 

 

 

 

 

 

 

1

2

3

4

 

 

1

2

3

4

ION ASSY

8FA2-5257-70500-0

33

Image 33
Contents KS1872 + C1872 + CL1872 KS2472 + C2472 + CL2472 DC Inverter Split System AIR ConditionerPlease Read Before Starting Table of Contents Checking Electrical Components Operating Range Models KS1872 + C1872 KS2472 + C2472Models KS1872 + CL1872 KS2472 + CL2472 Unit Specifications KS1872C1872 208V Single-Phase 60Hz C2472 KS2472KS2472 CL1872 KS1872 CL2472 KS2472 Indoor Unit Major Component SpecificationsCB-KS2472 Outdoor Unit Outdoor Unit C2472 Outdoor Unit CL1872 Outdoor Unit CL2472 Indoor heat exchanger sensor Other Component SpecificationsCompressor temp sensor Outdoor air temp sensorDimensional Data Outdoor Unit C1872 Outdoor Unit C2472 Refrigerant Flow Diagram Refrigerant Flow DiagramIndoor unit Outdoor unit Curve because it can cause the tube to break or crackPerformance Data Temperature ChartsIndoor Unit KS1872 Outdoor Unit CL1872 Indoor Unit KS2472 Outdoor Unit C2472 Indoor Unit KS2472 Outdoor Unit CL2472 Air Throw Distance Charts Cooling C1872 Cooling Electrical CharacteristicsC2472 Cooling CL2472Indoor Unit KS1872 KS2472 Electric Wiring DiagramsController Outdoor Unit C1872 CL18728FA2-5257-68700-3 8FA2-5257-68400-3 Installation Site Selection C2472, CL2472 C1872, CL1872AWG Recommended Wire Length and DiameterTo take out the remote control unit, pull it forward Remote Control Unit Installation PositionHow to Test Run the Air Conditioner Remove the Grille to Install the Indoor Unit How to remove the grilleHow to replace the grille Address Setting of the Remote Control Unit MaintenanceHow to Connect How to DisconnectOperation Functions FunctionsHigh Power Freeze prevention Protective FunctionsTroubleshooting Precautions before Performing Inspection or RepairMethod of Self-Diagnostics S01 Self-diagnostics LampsReplace the circuit board or the fuse Replace the controllerChecking the Indoor and Outdoor Units Using the TEST/T-RUN terminalsChecking the indoor unit Control Check items unit operation Checking the serial communicationsDiagnostic results Diagnostic procedureRemedy for symptom 3 to Trouble Diagnosis of Fan MotorOutdoor Fan Motor Noise Malfunction and Electromagnetic Interference Noise malfunctionElectromagnetic interference Measurement of Insulation Resistance Checking Electrical ComponentsChecking Continuity of Fuse on PCB Assy Characteristics of New Refrigerant R410A Refrigerant R410A Special Precautions When Servicing UnitChecklist before Servicing Tools Specifically for R410A Tubing Installation ProceduresFor servicing, use the following tools for R410A Tool Distinction Tool NameCase of Compressor Malfunction Recharging Configuration and characteristics of cylindersNever charge a large amount Unit. This may causeWelding leaking points Case Refrigerant is LeakingRetro-Fitting Existing Systems Charging Additional RefrigerantKS1872 + C1872 + CL1872 KS2472 + C2472 + CL2472 Features Contents Alert SymbolsProduct Information Installation Location Safety InstructionsElectrical Requirements Names of Parts Quiet lamp Unit Display and Operation ButtonRemote Control Unit Display HR. Timer button Remote Control UnitAdvance button TransmitterDRY Using the Remote Control Unit How to Install BatteriesACL button ALL Clear Using the Remote Control Unit Operation Operation with the Remote Control UnitPress the ON/OFF operation button Operation with the Remote Control UnitNight Setback Mode is used for saving energy Cooling and DRY ModeQuiet Mode Power failure during operation Special RemarksClicking sound is heard from the air conditioner Operation Indication Setting the TimerSetting the Timer To cancel a timer program Press the Cancel button1030 pm 710 am 1100 am Present time Setting procedure Using the 1-Hour OFF TimerCancellation procedure Operation together with the Daily ON/OFF Repeat TimerSetting the airflow manually Adjusting the Airflow DirectionHorizontal Sweep functionWhen the air conditioner is not running Care and CleaningOperation without the Remote Control UnitCleaning Care and CleaningWashing the grille with water Air clean filter How to clean the air clean filterFilter Negative ion generator metal electrodes inside plastic caseTroubleshooting Operating RangeTrouble Possible Cause Remedy

CL1872, CL2472, C1872, C2472 specifications

The Sanyo C1872, CL2472, CL1872, and C2472 models are notable additions to Sanyo's esteemed line of electronics, primarily focusing on providing high-quality performance in their respective categories. These models exemplify advanced technology coupled with user-friendly features, catering to both individual consumers and business professionals.

The Sanyo C1872 is particularly noteworthy for its compact design, making it highly portable. It offers excellent power efficiency without compromising on performance, making it suitable for outdoor activities or travel. This model integrates various cutting-edge technologies, ensuring durability and longevity. Key features include a high-capacity battery, allowing for extended usage periods, and an intuitive control interface that simplifies operation.

On the other hand, the CL2472 and CL1872 models are designed for robust functionality. These models are equipped with enhanced connectivity options, including Bluetooth and Wi-Fi capabilities, allowing users to easily link their devices for seamless data transfer. Both models also offer substantial storage capacity and can support multiple formats, which is essential for media-heavy applications.

The C2472 model stands out with its impressive display quality and resolution, ideal for professionals working in graphic design or video editing. It boasts a high-definition screen that provides vibrant colors and sharp details, enhancing the user experience significantly. Furthermore, the C2472 incorporates advanced processing technology, ensuring that tasks are completed efficiently without lag.

All these models are characterized by their reliability and build quality. Sanyo places a strong emphasis on durability, which is reflected in the materials used for these devices. They are designed to withstand everyday wear and tear, making them suitable for both personal and professional environments.

In summary, the Sanyo C1872, CL2472, CL1872, and C2472 are excellent examples of modern electronics, combining portability, advanced technology, and robust performance. Whether for leisure, work, or creative projects, these models offer features that meet a variety of user needs, ensuring that Sanyo remains a trusted name in the electronics market.