Sanyo C1872, C2472 Using the Remote Control Unit, ACL button ALL Clear, How to Install Batteries

Page 73

Remote Control Unit (continued)

SENSOR button

When you press this button (use a small-tipped object such as a ballpoint pen),

 

 

 

the

mark will appear at the display. And the room temperature is detected by

 

 

 

the sensor which is built into the indoor unit and the air conditioner is controlled

 

 

 

accordingly.

 

 

 

If the remote control is located near a heat source, such as a space heater or in direct

 

NOTE

 

 

 

 

sunlight, press the SENSOR button to switch to the sensor on the indoor unit.

 

 

 

 

 

 

 

Temperature Display Selector button

This switches the temperature display between °C and °F.

 

 

 

 

Time Display Selector button

This switches the time display between 24-hour time and 12-hour time.

 

 

 

 

ACL button (ALL CLEAR)

Puts the remote control unit into pre-operation status. Always press this button

 

 

 

after replacing the batteries.

 

 

 

 

ADDRESS switch

• The address switch changes to prevent mixing of signals from remote control

 

 

 

 

units when two air conditioners are installed next to each other. Normally, the

 

 

 

 

address switch is set to A. For more information, please contact the dealer

 

 

 

 

where you made the purchase.

 

 

 

• Normally, the tabs on the remote control unit should not be bent.

 

 

 

 

 

NOTE

The remote control unit sends the temperature signal to the air conditioner regularly at five minute intervals. If the signal from the remote control unit stops for more than 15 minutes due to the loss of the remote control unit or other trouble, the air conditioner will switch to the temperature sensor which is built into the indoor unit and control the room temperature. In these cases, the temperature around the remote control unit may differ from the temperature detected at the air conditioner’s position.

Using the Remote Control Unit

How to Install Batteries

1. Slide the cover in the direction indicated by the arrow and remove it.

2. Install two AAA alkaline batteries. Make sure the batteries point in the direction marked in the battery compartment.

3. Use a thin object such as the tip of a pen to press the ACL button.

ACL button

NOTE

The batteries last about six months, depending on how much you use the remote control unit. Replace the batteries when the remote control unit’s display fails to light, or when the remote control cannot be used to change the air conditioner’s settings.

Use two fresh leak-proof type-AAA alkaline batteries.

In replacing batteries, follow the instructions as mentioned in the sub- section “How to Install Batteries”.

If you do not use the remote control unit more than 1 month, take out the batteries.

10

OI-800-10-EG

 

Image 73
Contents KS1872 + C1872 + CL1872 KS2472 + C2472 + CL2472 DC Inverter Split System AIR ConditionerPlease Read Before Starting Table of Contents Checking Electrical Components Models KS1872 + C1872 KS2472 + C2472 Operating RangeModels KS1872 + CL1872 KS2472 + CL2472 KS1872 Unit SpecificationsC1872 208V Single-Phase 60Hz C2472 KS2472KS2472 CL1872 KS1872 CL2472 KS2472 Indoor Unit Major Component SpecificationsCB-KS2472 Outdoor Unit Outdoor Unit C2472 Outdoor Unit CL1872 Outdoor Unit CL2472 Indoor heat exchanger sensor Other Component SpecificationsCompressor temp sensor Outdoor air temp sensorDimensional Data Outdoor Unit C1872 Outdoor Unit C2472 Refrigerant Flow Diagram Refrigerant Flow DiagramIndoor unit Outdoor unit Curve because it can cause the tube to break or crackPerformance Data Temperature ChartsIndoor Unit KS1872 Outdoor Unit CL1872 Indoor Unit KS2472 Outdoor Unit C2472 Indoor Unit KS2472 Outdoor Unit CL2472 Air Throw Distance Charts Cooling C1872 Cooling Electrical CharacteristicsC2472 Cooling CL2472Indoor Unit KS1872 KS2472 Electric Wiring DiagramsController Outdoor Unit C1872 CL18728FA2-5257-68700-3 8FA2-5257-68400-3 Installation Site Selection C2472, CL2472 C1872, CL1872AWG Recommended Wire Length and DiameterTo take out the remote control unit, pull it forward Remote Control Unit Installation PositionHow to Test Run the Air Conditioner How to remove the grille Remove the Grille to Install the Indoor UnitHow to replace the grille Address Setting of the Remote Control Unit MaintenanceHow to Connect How to DisconnectOperation Functions FunctionsHigh Power Freeze prevention Protective FunctionsPrecautions before Performing Inspection or Repair TroubleshootingMethod of Self-Diagnostics S01 Self-diagnostics LampsReplace the circuit board or the fuse Replace the controllerChecking the Indoor and Outdoor Units Using the TEST/T-RUN terminalsChecking the indoor unit Control Check items unit operation Checking the serial communicationsDiagnostic results Diagnostic procedureRemedy for symptom 3 to Trouble Diagnosis of Fan MotorOutdoor Fan Motor Noise malfunction Noise Malfunction and Electromagnetic InterferenceElectromagnetic interference Measurement of Insulation Resistance Checking Electrical ComponentsChecking Continuity of Fuse on PCB Assy Characteristics of New Refrigerant R410A Refrigerant R410A Special Precautions When Servicing UnitChecklist before Servicing Tools Specifically for R410A Tubing Installation ProceduresFor servicing, use the following tools for R410A Tool Distinction Tool NameCase of Compressor Malfunction Recharging Configuration and characteristics of cylindersNever charge a large amount Unit. This may causeWelding leaking points Case Refrigerant is LeakingRetro-Fitting Existing Systems Charging Additional RefrigerantKS1872 + C1872 + CL1872 KS2472 + C2472 + CL2472 Features Alert Symbols ContentsProduct Information Safety Instructions Installation LocationElectrical Requirements Names of Parts Quiet lamp Unit Display and Operation ButtonRemote Control Unit Display HR. Timer button Remote Control UnitAdvance button TransmitterDRY How to Install Batteries Using the Remote Control UnitACL button ALL Clear Using the Remote Control Unit Operation Operation with the Remote Control UnitPress the ON/OFF operation button Operation with the Remote Control UnitNight Setback Mode is used for saving energy Cooling and DRY ModeQuiet Mode Special Remarks Power failure during operationClicking sound is heard from the air conditioner Operation Indication Setting the TimerTo cancel a timer program Press the Cancel button Setting the Timer1030 pm 710 am 1100 am Present time Setting procedure Using the 1-Hour OFF TimerCancellation procedure Operation together with the Daily ON/OFF Repeat TimerSetting the airflow manually Adjusting the Airflow DirectionHorizontal Sweep functionWhen the air conditioner is not running Care and CleaningOperation without the Remote Control UnitCleaning Care and CleaningWashing the grille with water Air clean filter How to clean the air clean filterFilter Negative ion generator metal electrodes inside plastic caseOperating Range TroubleshootingTrouble Possible Cause Remedy

CL1872, CL2472, C1872, C2472 specifications

The Sanyo C1872, CL2472, CL1872, and C2472 models are notable additions to Sanyo's esteemed line of electronics, primarily focusing on providing high-quality performance in their respective categories. These models exemplify advanced technology coupled with user-friendly features, catering to both individual consumers and business professionals.

The Sanyo C1872 is particularly noteworthy for its compact design, making it highly portable. It offers excellent power efficiency without compromising on performance, making it suitable for outdoor activities or travel. This model integrates various cutting-edge technologies, ensuring durability and longevity. Key features include a high-capacity battery, allowing for extended usage periods, and an intuitive control interface that simplifies operation.

On the other hand, the CL2472 and CL1872 models are designed for robust functionality. These models are equipped with enhanced connectivity options, including Bluetooth and Wi-Fi capabilities, allowing users to easily link their devices for seamless data transfer. Both models also offer substantial storage capacity and can support multiple formats, which is essential for media-heavy applications.

The C2472 model stands out with its impressive display quality and resolution, ideal for professionals working in graphic design or video editing. It boasts a high-definition screen that provides vibrant colors and sharp details, enhancing the user experience significantly. Furthermore, the C2472 incorporates advanced processing technology, ensuring that tasks are completed efficiently without lag.

All these models are characterized by their reliability and build quality. Sanyo places a strong emphasis on durability, which is reflected in the materials used for these devices. They are designed to withstand everyday wear and tear, making them suitable for both personal and professional environments.

In summary, the Sanyo C1872, CL2472, CL1872, and C2472 are excellent examples of modern electronics, combining portability, advanced technology, and robust performance. Whether for leisure, work, or creative projects, these models offer features that meet a variety of user needs, ensuring that Sanyo remains a trusted name in the electronics market.