Sanyo CL2472, C2472, C1872, CL1872 service manual Filter, How to clean the air clean filter

Page 86

 

Care and Cleaning (continued)

Air Clean Filter

The air clean filter removes dust and dirt from the air, and reduces odors and

 

smoke from tobacco.

 

This air clean filter cannot remove harmful gases or vapors nor ventilate air in

 

the room. You must open doors or windows frequently when you use gas or oil

 

heating appliances. Otherwise there is a risk of suffocation in extreme cases.

How to install the air clean

The air clean filter needs to be installed behind the air intake grille.

filter

1.

Remove the air intake grille.

 

2.

Install the air clean filter in the

 

 

position shown in the figure.

 

3.

Remount the air intake grille.

How to clean the air clean filter

NOTE

Cleaning the main unit and remote control unit

Removing and remounting the air intake grille

CAUTION

Washing the grille with water

Air clean filter

In general, the filter should be sucked to remove dust in low fan speed of a vacuum cleaner once every three months.

If there is heavily grime on the filter, soak the filter in lukewarm water with neutral detergent diluted 1:500 for 1 to 2 minutes then wash it.

Rinse the filter in clean water, then let it dry on the towel in room temperature.

Do not bend nor give excessive force onto the air clean filter.

If the filter surface is heavily blocked with dirt or damaged, replace it with new one. Purchase a replacement filter at your local dealer. (model STK-FDXB)

Wipe clean using a soft, dry cloth.

To remove stubborn dirt, moisten a cloth in warm water no hotter than 104 °F, wring thoroughly, and then wipe.

The air intake grille can be removed in order to wash it with water.

Refer to “How to remove the anti-mold filter” and “How to replace the anti-mold filter” on page 22.

When using a footstool or the like, be careful not to let it tip over.

Clean the grille gently using a soft sponge, or the like. Then wipe away any remaining moisture.

Neutral detergent may be used to remove stubborn dirt. Then rinse thoroughly with water and wipe away any remaining moisture.

Cleaning the negative ion generator

Follow the steps below when the generator has become dirty.

For safety, be sure to turn the air conditioner off and also to disconnect the power before cleaning.

Remove the dust on the negative ion generator.

Use a toothbrush, etc. to dust off the end.

Use a cotton swab, etc., to clean around the generator inside the plastic case, taking care not to touch the electrodes.

Negative ion generator (metal electrodes inside plastic case)

NOTE

During use, the negative ion generator and other metal parts may become discolored: this is normal and not indicative of malfunctioning.

If the dirt on and around the negative ion generator is left to build up, a puffing or sputtering sound will eventually be heard. In this case, clean the generator immediately.

Do not apply excessive force while performing maintenance.

OI-800-23-EG

23

 

Image 86
Contents DC Inverter Split System AIR Conditioner KS1872 + C1872 + CL1872 KS2472 + C2472 + CL2472Please Read Before Starting Table of Contents Checking Electrical Components Models KS1872 + CL1872 KS2472 + CL2472 Operating RangeModels KS1872 + C1872 KS2472 + C2472 C1872 Unit SpecificationsKS1872 208V Single-Phase 60Hz KS2472 C2472KS2472 CL1872 KS1872 CL2472 KS2472 Major Component Specifications Indoor UnitCB-KS2472 Outdoor Unit Outdoor Unit C2472 Outdoor Unit CL1872 Outdoor Unit CL2472 Compressor temp sensor Other Component SpecificationsIndoor heat exchanger sensor Outdoor air temp sensorDimensional Data Outdoor Unit C1872 Outdoor Unit C2472 Indoor unit Outdoor unit Refrigerant Flow DiagramRefrigerant Flow Diagram Curve because it can cause the tube to break or crackTemperature Charts Performance DataIndoor Unit KS1872 Outdoor Unit CL1872 Indoor Unit KS2472 Outdoor Unit C2472 Indoor Unit KS2472 Outdoor Unit CL2472 Air Throw Distance Charts Cooling Electrical Characteristics C1872 CoolingCL2472 C2472 CoolingElectric Wiring Diagrams Indoor Unit KS1872 KS2472Outdoor Unit C1872 CL1872 Controller8FA2-5257-68700-3 8FA2-5257-68400-3 Installation Site Selection C1872, CL1872 C2472, CL2472Recommended Wire Length and Diameter AWGRemote Control Unit Installation Position To take out the remote control unit, pull it forwardHow to Test Run the Air Conditioner How to replace the grille Remove the Grille to Install the Indoor UnitHow to remove the grille Maintenance Address Setting of the Remote Control UnitHow to Disconnect How to ConnectFunctions Operation FunctionsHigh Power Protective Functions Freeze preventionMethod of Self-Diagnostics TroubleshootingPrecautions before Performing Inspection or Repair Self-diagnostics Lamps S01Replace the controller Replace the circuit board or the fuseChecking the indoor unit Control Check items unit operation Using the TEST/T-RUN terminalsChecking the Indoor and Outdoor Units Checking the serial communicationsRemedy for symptom 3 to Diagnostic procedureDiagnostic results Trouble Diagnosis of Fan MotorOutdoor Fan Motor Electromagnetic interference Noise Malfunction and Electromagnetic InterferenceNoise malfunction Checking Electrical Components Measurement of Insulation ResistanceChecking Continuity of Fuse on PCB Assy Refrigerant R410A Special Precautions When Servicing Unit Characteristics of New Refrigerant R410AChecklist before Servicing For servicing, use the following tools for R410A Tubing Installation ProceduresTools Specifically for R410A Tool Distinction Tool NameCase of Compressor Malfunction Never charge a large amount Configuration and characteristics of cylindersRecharging Unit. This may causeCase Refrigerant is Leaking Welding leaking pointsCharging Additional Refrigerant Retro-Fitting Existing SystemsKS1872 + C1872 + CL1872 KS2472 + C2472 + CL2472 Features Product Information ContentsAlert Symbols Electrical Requirements Installation LocationSafety Instructions Names of Parts Unit Display and Operation Button Quiet lampRemote Control Unit Display Advance button Remote Control UnitHR. Timer button TransmitterDRY ACL button ALL Clear Using the Remote Control UnitHow to Install Batteries Using the Remote Control Unit Operation with the Remote Control Unit OperationOperation with the Remote Control Unit Press the ON/OFF operation buttonCooling and DRY Mode Night Setback Mode is used for saving energyQuiet Mode Clicking sound is heard from the air conditioner Power failure during operationSpecial Remarks Setting the Timer Operation Indication1030 pm 710 am 1100 am Present time Setting the TimerTo cancel a timer program Press the Cancel button Cancellation procedure Using the 1-Hour OFF TimerSetting procedure Operation together with the Daily ON/OFF Repeat TimerHorizontal Adjusting the Airflow DirectionSetting the airflow manually Sweep functionOperation without the Remote Care and CleaningWhen the air conditioner is not running Control UnitCare and Cleaning CleaningFilter How to clean the air clean filterWashing the grille with water Air clean filter Negative ion generator metal electrodes inside plastic caseTrouble Possible Cause Remedy TroubleshootingOperating Range

CL1872, CL2472, C1872, C2472 specifications

The Sanyo C1872, CL2472, CL1872, and C2472 models are notable additions to Sanyo's esteemed line of electronics, primarily focusing on providing high-quality performance in their respective categories. These models exemplify advanced technology coupled with user-friendly features, catering to both individual consumers and business professionals.

The Sanyo C1872 is particularly noteworthy for its compact design, making it highly portable. It offers excellent power efficiency without compromising on performance, making it suitable for outdoor activities or travel. This model integrates various cutting-edge technologies, ensuring durability and longevity. Key features include a high-capacity battery, allowing for extended usage periods, and an intuitive control interface that simplifies operation.

On the other hand, the CL2472 and CL1872 models are designed for robust functionality. These models are equipped with enhanced connectivity options, including Bluetooth and Wi-Fi capabilities, allowing users to easily link their devices for seamless data transfer. Both models also offer substantial storage capacity and can support multiple formats, which is essential for media-heavy applications.

The C2472 model stands out with its impressive display quality and resolution, ideal for professionals working in graphic design or video editing. It boasts a high-definition screen that provides vibrant colors and sharp details, enhancing the user experience significantly. Furthermore, the C2472 incorporates advanced processing technology, ensuring that tasks are completed efficiently without lag.

All these models are characterized by their reliability and build quality. Sanyo places a strong emphasis on durability, which is reflected in the materials used for these devices. They are designed to withstand everyday wear and tear, making them suitable for both personal and professional environments.

In summary, the Sanyo C1872, CL2472, CL1872, and C2472 are excellent examples of modern electronics, combining portability, advanced technology, and robust performance. Whether for leisure, work, or creative projects, these models offer features that meet a variety of user needs, ensuring that Sanyo remains a trusted name in the electronics market.