Sanyo Cool/Dry Installation Site Selection, Additional Materials Required for Installation

Page 4

05-424 KS0971-1271 12/13/05 1:27 PM Page 4

1-5. Additional Materials Required for Installation

1.Refrigeration (armored) tape

2.Insulated staples or clamps for connecting wire (See local codes)

3.Putty

4.Refrigeration lubricant

5.Clamps or saddles to secure refrigerant tubing

2. Installation Site Selection

Indoor unit

Drain hose

Outside drainage

2-1. Indoor Unit

WARNING

AVOID:

direct sunlight.

To prevent abnormal heat genera- tion and the possibility of fire, do not place obstacles, enclosures and grilles in front of or surround- ing the air conditioner in a way that may block air flow.

Fig. 1

 

6" (15 cm)

2" (5 cm)

2" (5 cm)

min.

 

min.

min.

 

 

 

 

Front View

 

nearby heat sources that may affect performance of the unit.

areas where leakage of flammable gas may be expected.

places where large amounts of oil mist exist.

 

Fig. 2

 

 

Tubing length (L)

INDOOR

 

UNIT

 

 

 

 

 

DO:

select an appropriate position from which every corner of the room can be uniformly cooled. (High on a wall is best.)

select a location that will hold the weight of the unit.

Elevation difference (H)

OUTDOOR UNIT

select a location where tubing and drain hose have the

shortest run to the outside. (Fig. 1)

Fig. 3a

allow room for operation and maintenance as well as unre-

stricted air flow around the unit. (Fig. 2)

install the unit within the maximum elevation difference (H)

above or below the outdoor unit and within a total tubing length

(L) from the outdoor unit as detailed in Table 3 and Fig. 3a.

Install the indoor unit more than 3.3' (1 m) away from any

antenna or power lines or connecting wires used for television,

radio, telephone, security system, or intercom. Electrical noise

from any of these sources may affect operation.

CAUTION

For stable operation of the air conditioner, do not install wall-mounted type indoor units less than 5' (1.5 m) from floor level.

Indoor unit

Wall

Minimum height from floor level

5' (1.5 m)

Table 3

Floor level

Fig. 3b

 

Max. Allowable Tubing

Limit of Tubing

Limit of Elevation

Required Amount of

Model

Length at Shipment

Length (L)

Difference (H)

Additional Refrigerant

 

(ft.)

(ft.)

(ft.)

(oz./ft.)*

 

 

 

 

 

KS0971

25

50

23

0.16

 

 

 

 

 

KS1271

25

65

23

0.16

 

 

 

 

 

*If total tubing length becomes 25 ft. (max.), charge additional refrigerant (R410A) by 0.16 oz./ft. No additional charge of compressor oil is necessary.

4

Image 4
Contents Installation Instructions ContentsFor safe installation and trouble-free operation, you must …In a Ceiling or Wall…In a Room …In Moist or Uneven LocationsTools Required for Installation not supplied Accessories Supplied with Unit TableGeneral Optional Copper Tubing KitAdditional Materials Required for Installation Installation Site SelectionIndoor Unit Outdoor Unit Baffle Plate for the Outdoor Unit CLxx models onlyHow to Install the Indoor Unit Trical wiring or conduits areRemove the Rear Panel from the Unit Make a HoleInstall the Rear Panel on the Wall If Wooden WallIf Block, Brick, Concrete or Similar Type Wall Hole DiaRemove the Grille to Install the Indoor Unit How to replace the grilleWiring Instructions General precautions on wiring Shape the Indoor Side TubingRecommended Wire Length and Diameter Wiring Instructions for Inter-unit Connections For Outdoor Unit For solid core wiring or F-cable How to connect wiring to the terminal For Indoor UnitFor stranded wiring Mounting Right-side tubingSwitching drain hose and drain cap Left-side tubingDrain hose Drain capDo not supply power to Tubing and wiring to the outTo unmount indoor unit Unit or operate it until allFirst refer to . Installation Site Selection How to Install the Outdoor UnitWiring Instructions for the Outdoor Unit Flaring Procedure with a Flare Tool To 0.5 mm Adjust so that the amount of tubeRefrigerant Tubing Use of the Flaring MethodConnecting Tubing between Indoor and Outdoor Units Finishing the InstallationInsulation of Refrigerant Tubing To prevent heat loss and wet floors due to dripping of conAir Purging Hex wrench before Be sure to completely insertAttempting to turn the valve How to Test Run the Air Conditioner Basic Functions of the Service Valves Pump DownTo take out the remote control unit, pull it forward Remote Control Unit Installation PositionMounting on a Wall Address Switch Address Setting of the Remote Control Unit

Cool/Dry specifications

The Sanyo Cool/Dry air conditioning unit is a versatile and efficient solution designed to provide optimal indoor comfort across varying climate conditions. Known for its advanced technologies and features, the Sanyo Cool/Dry offers an ideal balance between performance and energy efficiency, making it a popular choice among consumers looking for reliable cooling and dehumidifying capabilities.

One of the standout features of the Sanyo Cool/Dry is its multi-function capability. This unit is designed to operate in two modes: cool and dry, allowing users to effortlessly switch between air conditioning and dehumidification based on their needs. The cooling function ensures that rooms are kept at comfortable temperatures even during the hottest days, while the dry mode effectively reduces humidity levels, promoting a healthier indoor environment.

Energy efficiency is a hallmark of this model, as it includes advanced technologies that minimize energy consumption without sacrificing performance. The Sanyo Cool/Dry is equipped with a high-efficiency compressor that adapts its power according to the cooling demand. This inverter technology not only ensures a quieter operation but also significantly reduces electricity bills, making it an eco-friendly choice for environmentally-conscious consumers.

This air conditioning unit also comes with an intelligent control system that allows for easy operation and programming. Users can adjust their desired temperature settings with a remote control, which enhances convenience. Some models may even feature smart home integration capabilities, enabling users to monitor and control their air conditioning units through smartphone applications.

Another important characteristic of the Sanyo Cool/Dry is its air purification features. Many models include advanced filters designed to capture allergens, dust, and other airborne particles, helping to improve indoor air quality. This is particularly beneficial for those with allergies or respiratory issues, as it creates a cleaner and healthier living space.

Quiet operation is another highlight of the Sanyo Cool/Dry, making it suitable for residential environments where noise levels need to be kept to a minimum. This is ideal for bedrooms, offices, or any space where tranquility is prized.

In summary, the Sanyo Cool/Dry air conditioning unit combines efficiency, versatility, and user-friendly features, making it a standout option for those seeking effective climate control solutions. With its dual-mode functionality, energy-efficient technology, smart operation, and air purification capabilities, it satisfies a wide range of consumer needs while enhancing overall comfort in living and working spaces.