Sanyo Cool/Dry installation instructions Baffle Plate for the Outdoor Unit CLxx models only

Page 5

05-424 KS0971-1271 12/13/05 1:27 PM Page 5

2-2. Outdoor Unit

AVOID:

heat sources, exhaust fans, etc. (Fig. 4)

damp, humid or uneven locations.

DO:

choose a place as cool as possible.

choose a place that is well ventilated.

allow enough room around the unit for air intake/ exhaust and possible maintenance. (Fig. 5a)

provide a solid base (level concrete pad, concrete block, 4" 1'4" (10 40 cm) beams or equal), a mini- mum of 4" (10 cm) above ground level to reduce humidity and protect the unit against possible water damage and decreased service life. (Fig. 5b)

Install cushion rubber under unit’s feet to reduce vibration and noise. (Fig. 5c)

use lug bolts or equal to bolt down unit, reducing vibration and noise.

Install in a location where no antenna of a television or radio exists within 10' (3 m).

2-3. Baffle Plate for the Outdoor Unit (CLxx models only)

NOTE

It is recommended to use baffle plates for models CL0971 and CL1271. The baffle plates are not normally required for the other models.

When the outdoor unit is installed in a position exposed to strong wind (like seasonal winds with low air tempera- ture in winter), baffle plates must be installed in front of the outdoor unit. (Fig. 5d)

This unit is designed so that the fan of the outdoor unit runs at low speed when the air conditioner is operated at low outdoor air temperatures. When the outdoor unit is exposed to strong wind, the system pressure drops because of the freeze protector.

Baffle

6" min

Baffle

plate

ge

plate

min

Air dischar

 

6"

 

 

Air discharge

Fig. 5d

NO

Exhaust fan

Hot air

Heat source

Outdoor unit

Fig. 4

 

 

 

 

 

 

Obstacle above

 

 

 

 

 

 

Min. 10"

discharge

 

 

Min.

Min.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air intake

Min. 2" (5 cm)

Valve

 

 

7' (2 m) 7' (2 m)

 

 

 

 

 

side

 

 

 

 

 

 

 

 

 

 

 

(25 cm)

Air

 

 

 

Obstacle

Min.

Air discharge Min.

 

 

 

 

 

 

 

 

 

 

 

2" (5 cm)

 

 

 

 

 

 

 

 

 

 

8" (20 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 5a

 

Ground

Min. 2" (5 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air intake

 

 

 

 

 

 

 

 

Anchor bolts

 

 

 

 

 

 

 

 

 

(4 pcs.)

 

Air intake

 

 

 

 

 

 

 

 

Min. 4" (10 cm)

 

 

 

 

 

 

 

 

 

 

Concrete

 

 

 

 

 

 

 

 

 

 

 

or equal

 

 

 

 

 

 

 

 

 

 

 

 

About

 

 

 

 

4"

(10

cm)

 

 

 

 

 

 

 

 

 

 

16"

 

 

 

About

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(40

cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 5b

Cushion rubber

Fig. 5c

5

Image 5
Contents Contents Installation Instructions…In a Ceiling or Wall For safe installation and trouble-free operation, you must…In a Room …In Moist or Uneven LocationsAccessories Supplied with Unit Table Tools Required for Installation not suppliedGeneral Optional Copper Tubing KitIndoor Unit Installation Site SelectionAdditional Materials Required for Installation Baffle Plate for the Outdoor Unit CLxx models only Outdoor UnitTrical wiring or conduits are How to Install the Indoor UnitRemove the Rear Panel from the Unit Make a HoleIf Wooden Wall Install the Rear Panel on the WallIf Block, Brick, Concrete or Similar Type Wall Hole DiaHow to replace the grille Remove the Grille to Install the Indoor UnitShape the Indoor Side Tubing Wiring Instructions General precautions on wiringRecommended Wire Length and Diameter Wiring Instructions for Inter-unit Connections For stranded wiring How to connect wiring to the terminal For Indoor UnitFor Outdoor Unit For solid core wiring or F-cable Right-side tubing MountingLeft-side tubing Switching drain hose and drain capDrain hose Drain capTubing and wiring to the out Do not supply power toTo unmount indoor unit Unit or operate it until allWiring Instructions for the Outdoor Unit How to Install the Outdoor UnitFirst refer to . Installation Site Selection To 0.5 mm Adjust so that the amount of tube Flaring Procedure with a Flare ToolRefrigerant Tubing Use of the Flaring MethodFinishing the Installation Connecting Tubing between Indoor and Outdoor UnitsInsulation of Refrigerant Tubing To prevent heat loss and wet floors due to dripping of conAir Purging Attempting to turn the valve Be sure to completely insertHex wrench before How to Test Run the Air Conditioner Pump Down Basic Functions of the Service ValvesMounting on a Wall Remote Control Unit Installation PositionTo take out the remote control unit, pull it forward Address Setting of the Remote Control Unit Address Switch

Cool/Dry specifications

The Sanyo Cool/Dry air conditioning unit is a versatile and efficient solution designed to provide optimal indoor comfort across varying climate conditions. Known for its advanced technologies and features, the Sanyo Cool/Dry offers an ideal balance between performance and energy efficiency, making it a popular choice among consumers looking for reliable cooling and dehumidifying capabilities.

One of the standout features of the Sanyo Cool/Dry is its multi-function capability. This unit is designed to operate in two modes: cool and dry, allowing users to effortlessly switch between air conditioning and dehumidification based on their needs. The cooling function ensures that rooms are kept at comfortable temperatures even during the hottest days, while the dry mode effectively reduces humidity levels, promoting a healthier indoor environment.

Energy efficiency is a hallmark of this model, as it includes advanced technologies that minimize energy consumption without sacrificing performance. The Sanyo Cool/Dry is equipped with a high-efficiency compressor that adapts its power according to the cooling demand. This inverter technology not only ensures a quieter operation but also significantly reduces electricity bills, making it an eco-friendly choice for environmentally-conscious consumers.

This air conditioning unit also comes with an intelligent control system that allows for easy operation and programming. Users can adjust their desired temperature settings with a remote control, which enhances convenience. Some models may even feature smart home integration capabilities, enabling users to monitor and control their air conditioning units through smartphone applications.

Another important characteristic of the Sanyo Cool/Dry is its air purification features. Many models include advanced filters designed to capture allergens, dust, and other airborne particles, helping to improve indoor air quality. This is particularly beneficial for those with allergies or respiratory issues, as it creates a cleaner and healthier living space.

Quiet operation is another highlight of the Sanyo Cool/Dry, making it suitable for residential environments where noise levels need to be kept to a minimum. This is ideal for bedrooms, offices, or any space where tranquility is prized.

In summary, the Sanyo Cool/Dry air conditioning unit combines efficiency, versatility, and user-friendly features, making it a standout option for those seeking effective climate control solutions. With its dual-mode functionality, energy-efficient technology, smart operation, and air purification capabilities, it satisfies a wide range of consumer needs while enhancing overall comfort in living and working spaces.