TIMER OPERATION

NOTE:

Before setting the timer, make sure the clock is properly set with the current time.

TIMER OFF

MODE

1h

1

 

 

FAN

 

2

SWING

 

 

SET/C

3

 

 

1 Press the TIMER OFF ( ) button.

2 The TIMER OFF indicator will blink; press the TIME ADVANCE or REVERSE buttons to set the desired time. (The time can be set in 10- minute increments.)

3 Point the remote control at the signal receiver window on the unit and press the TIMER SET (SET/C) button.

The orange TIMER lamp ( ) on the unit will light.

The unit will generate a beep when it receives the signal.

TIPS ABOUT TIMER OFF OPERATION

When the TIMER OFF mode is set, the temperature setting is automatically adjusted to prevent the room from becoming excessively hot or too cold while you sleep. (Auto Sleep function)

COOL/DRY MODE:

One hour after the time operation begins, the temperature setting rises 1°C higher than the original temperature setting.

HEAT MODE:

One hour after the timer operation begins, the temperature setting drops 3°C lower than the original thermostat setting.

TO CANCEL TIMER MODE

Press the TIMER CANCEL (SET/C) button.

• The orange TIMER lamp ( ) on the unit will

turn off.

 

 

 

• The

current

clock

 

 

time

will be

dis-

MODE

1h

played on the re-

 

 

mote control.

 

 

 

 

 

 

FAN

 

 

 

 

SWING

 

 

 

 

 

SET/C

NOTE:

If any TIMER ON, TIMER OFF and ONE-HOUR OFF TIMER are set, the TIMER CANCEL but- ton cancels all settings.

TO CHANGE TIME SETTING

Cancel the TIMER setting first, then set it again.

E-12

Image 14
Contents GS-XP07FR GS-XP09FR GS-XP12FR GS-XP18FR GS-XP24FR GS-XP27FR Other Countries outside the EU Contents Important Safety InstructionsPlace Down or drop, causing injuryTime Kennel or greenhouse to raise animals or grow plantsAdditional Notes on Operation Tips on Saving EnergyPart Names AUXRemote Control Between the remote control Using the Remote ControlHOW to USE the Remote Control Make sure There Is noSET Current Clock Time Red Operation lamp on the unit will turn off Basic OperationRed Operation lamp on the unit will light Tips about Auto Mode Mode ChangeoverVertical AIR Flow Direction Adjusting the AIR Flow DirectionHOW to Adjust the AIR Flow Direction Horizontal AIR Flow DirectionTo Cancel Full Power OperationONE-HOUR OFF Timer COOL/DRY Mode Timer OperationTimer OFF Heat ModeTimer on Select the operation conditionDuringbutton. operation, press the Plasmacluster Tips about Plasmacluster OperationPlasmacluster Operation Press the Plasmacluster button againCleaning the Unit and the Remote Control Auxiliary ModeMaintenance To Turn onTurn OFF the Unit Open the Intake Grille If the Unit Fails to Operate Before Calling for ServiceIf the Unit Fails to Receive the Remote Control Signal If the Unit Fails to Cool or Heat the Room EffectivelySharp Corporation OSAKA, Japan

GS-XP12FR, GS-XP18FR, GS-XP24FR, GS-XP27FR, GS-XP09FR specifications

The Sharp GS-XP series of air conditioners, including models GS-XP07FR, GS-XP18FR, GS-XP27FR, GS-XP09FR, and GS-XP24FR, offers a range of innovative solutions for maintaining optimal indoor climate conditions. These models are engineered for efficiency, comfort, and advanced technology, making them an excellent choice for both residential and commercial applications.

One of the standout features of the Sharp GS-XP series is their inverter technology. This technology allows the air conditioners to adjust the compressor speed according to the cooling or heating demand, significantly reducing energy consumption while maintaining a consistent and comfortable temperature. This is particularly beneficial in regions with varying climate conditions, as it ensures that the unit operates efficiently throughout the year.

The GS-XP series also includes advanced air purification systems, incorporating Sharp's proprietary Plasmacluster technology. This feature ensures that the air produced is not only cool but also free of harmful particles, allergens, and odors. The Plasmacluster ions disperse throughout the room, enhancing air quality and providing a healthier living environment.

Another important characteristic of the GS-XP models is their user-friendly controls. Equipped with intuitive remote controls and smart features, users can easily set their desired temperature and mode. Some models even support Wi-Fi connectivity, allowing for remote operation via smartphone applications. This feature enables users to adjust settings and monitor energy usage from virtually anywhere, adding an extra layer of convenience.

The build quality of the Sharp GS-XP series is also noteworthy. The units are designed to withstand various environmental conditions, ensuring longevity and reliable performance. Additionally, they operate quietly, which is essential for residential spaces where noise can be a significant concern.

In terms of design, the GS-XP models feature sleek and modern aesthetics that can seamlessly fit into any décor. Their compact size also makes them suitable for installation in tight spaces.

All these features come together to create a comprehensive solution for climate control. The Sharp GS-XP series not only emphasizes energy efficiency and air quality but also prioritizes user convenience and aesthetic appeal, making them a leading choice in today’s air conditioning market.