Sharp GS-XP24FR, GS-XP07FR, GS-XP09FR, GS-XP27FR, GS-XP18FR, GS-XP12FR SET Current Clock Time

Page 9

CAUTION

Do not allow the signal receiver window to receive strong direct sunlight, since it can adversely affect its operation. If the signal receiver window is exposed to direct sunlight, close a curtain to block the light.

Using a fluorescent lamp with a quick starter in the same room may interfere with transmission of the signal.

The unit can be affected by signals transmitted from the remote control of a television, VCR or other equipment used in the same room.

Do not leave the remote control in direct sunlight or near a heater. Also, protect the unit and remote control from moisture and shock which can discolour or damage them.

ENGLISH

SET CURRENT CLOCK TIME

There are two clock modes: 12-hour mode and 24-hour mode.

Example: 5 o'clock in the afternoon

Clock

Display

12-hour mode

PM 5:00

 

24-hour mode

17:00

 

MODE

1h

 

 

1

To set to the 12-hour mode, press the

 

 

 

 

 

 

 

 

 

CLOCK button once in the first step.

 

 

 

 

 

To set to the 24-hour mode, press the

FAN

 

 

2

 

CLOCK button twice in the first step.

SWING

 

 

 

Press the TIME ADVANCE or REVERSE

 

 

 

3

2 button to set the current time.

 

 

SET/C

 

• Keep the button pressed to advance

 

 

 

 

 

 

 

 

 

or reverse the time display quickly.

13 Press the SET/C button.

The colon (:) blinks to indicate that the clock is functioning.

NOTE:

The current time cannot be set when the timer is operating.

E-7

Image 9
Contents GS-XP07FR GS-XP09FR GS-XP12FR GS-XP18FR GS-XP24FR GS-XP27FR Other Countries outside the EU Important Safety Instructions ContentsTime Down or drop, causing injuryPlace Kennel or greenhouse to raise animals or grow plantsTips on Saving Energy Additional Notes on OperationAUX Part NamesRemote Control HOW to USE the Remote Control Using the Remote ControlBetween the remote control Make sure There Is noSET Current Clock Time Basic Operation Red Operation lamp on the unit will lightRed Operation lamp on the unit will turn off Mode Changeover Tips about Auto ModeHOW to Adjust the AIR Flow Direction Adjusting the AIR Flow DirectionVertical AIR Flow Direction Horizontal AIR Flow DirectionFull Power Operation ONE-HOUR OFF TimerTo Cancel Timer OFF Timer OperationCOOL/DRY Mode Heat ModeSelect the operation condition Timer onPlasmacluster Operation Tips about Plasmacluster OperationDuringbutton. operation, press the Plasmacluster Press the Plasmacluster button againMaintenance Auxiliary ModeCleaning the Unit and the Remote Control To Turn onTurn OFF the Unit Open the Intake Grille If the Unit Fails to Receive the Remote Control Signal Before Calling for ServiceIf the Unit Fails to Operate If the Unit Fails to Cool or Heat the Room EffectivelyOSAKA, Japan Sharp Corporation

GS-XP12FR, GS-XP18FR, GS-XP24FR, GS-XP27FR, GS-XP09FR specifications

The Sharp GS-XP series of air conditioners, including models GS-XP07FR, GS-XP18FR, GS-XP27FR, GS-XP09FR, and GS-XP24FR, offers a range of innovative solutions for maintaining optimal indoor climate conditions. These models are engineered for efficiency, comfort, and advanced technology, making them an excellent choice for both residential and commercial applications.

One of the standout features of the Sharp GS-XP series is their inverter technology. This technology allows the air conditioners to adjust the compressor speed according to the cooling or heating demand, significantly reducing energy consumption while maintaining a consistent and comfortable temperature. This is particularly beneficial in regions with varying climate conditions, as it ensures that the unit operates efficiently throughout the year.

The GS-XP series also includes advanced air purification systems, incorporating Sharp's proprietary Plasmacluster technology. This feature ensures that the air produced is not only cool but also free of harmful particles, allergens, and odors. The Plasmacluster ions disperse throughout the room, enhancing air quality and providing a healthier living environment.

Another important characteristic of the GS-XP models is their user-friendly controls. Equipped with intuitive remote controls and smart features, users can easily set their desired temperature and mode. Some models even support Wi-Fi connectivity, allowing for remote operation via smartphone applications. This feature enables users to adjust settings and monitor energy usage from virtually anywhere, adding an extra layer of convenience.

The build quality of the Sharp GS-XP series is also noteworthy. The units are designed to withstand various environmental conditions, ensuring longevity and reliable performance. Additionally, they operate quietly, which is essential for residential spaces where noise can be a significant concern.

In terms of design, the GS-XP models feature sleek and modern aesthetics that can seamlessly fit into any décor. Their compact size also makes them suitable for installation in tight spaces.

All these features come together to create a comprehensive solution for climate control. The Sharp GS-XP series not only emphasizes energy efficiency and air quality but also prioritizes user convenience and aesthetic appeal, making them a leading choice in today’s air conditioning market.