Sharp CV-P09FR Dehumidification Mode, Press the Mode button to select DEHU- Midification mode

Page 12

DEHUMIDIFICATION MODE

In this mode, the air conditioner dehumidifies the room.

Drainage nozzle

Stopcock

“OPEN position”

1 Remove the exhaust hose (See Page 8)

2 Turn the drainage nozzle to the OPEN position.

3 Pull the stopcock out from the drainage nozzle.

When the stopcock is removed, a small amount of water may be discharged from the drainage nozzle.

Always perform this procedure with the unit turned off. Drain water will spout out if attempted during operation.

Hose clamp

Hose

7

6

4 Insert the hose clamp into a standard commercially-available hose (12.7 mm in- ner diameter, 16.7 mm outer diameter)

5 Attach the hose to the drainage nozzle, and secure it with the hose clamp.

Depending on room condition, approximately 28 liters of water per day (24 hours) will be dehumidified.

Prepare some kind of bucket of appropriate size to collect drain water, or take some appro- priate measure to drain the water outside of the room, so that drain water will not overflow or soak your room.

Set the hose sloping downwards for easier drainage. Moreover, do not bend the hose at any point, nor allow the end to be submerged in water.

6 Press the MODE button to select DEHU- MIDIFICATION mode.

COOL DEHUM FAN VENT

7 Presstion. the ON/OFF button to start opera-

The red OPERATION lamp ( )on the unit will light.

The temperature cannot be set.

The fan speed is preset to AUTO and cannot be changed.

TO TURN OFF

Press the ON/OFF button again.

The red OPERATION lamp ( )on the unit will turn off.

CAUTION

The unit generates heat during dehumidification mode and the room temperature will rise. Install the exhaust hose if you do not want the room temperature to rise. This will help to slightly drop the room temperature, but dehumidification performance will become less effective than when operating without the exhaust hose.

E-10

Image 12
Contents CV P09FR Other Countries outside the EU Contents Important Safety InstructionsUsage Cautions Operating ConditionsLocation IncludedEnergy Efficiency Tips Part Names Front ViewRear View Remote Control Remote Control DisplayUsing the Remote Control Loading Batteries Use two AAA R03 batteriesHOW to USE the Remote Control Installation and Removal of Exhaust Hose Attach the insect guard net to the ex- haust adapterAttach the Exhaust adapter to the exhaust hose Attach the exhaust hose adapter to the unitCool Mode Press the Temperature button to set the desired temperaturePress the ON/OFF button to start op- eration Press the FAN button to set the de- sired fan speedDehumidification Mode Press the Mode button to select DEHU- Midification modePresstion. the ON/OFF button to start opera FAN Mode Ventilation ModePress the Mode button to select FAN mode Press the Mode button to select Vent modePress the Swing button on the remote control To Change AIR Flow DirectionUP/DOWN AIR Flow Direction LEFT/RIGHT AIR Flow DirectionONE-HOUR OFF Timer Press the Cancel buttonTurbo Cool Operation Press the Turbo Cool button againTimer Operation OFF TimerPress the OFF Timer Time as desiredOn Timer Press the on Timer buttonAuxiliary Mode Plasmacluster OperationPress the Plasmacluster button again Press the AUX. button againDrainage Press the AUX. button on the unit twiceTurn the drainage nozzle to the Close position Replace the stopcock to the drainpipe nozzleMaintenance Cleaning the FiltersCleaning the Unit and the Remote Control Cleaning the Insect Guard NETBefore Calling for Service AIR Conditioner does not Operate AT ALLSharp Corporation

CV-P09FR specifications

The Sharp CV-P09FR is a compact, energy-efficient air conditioner that stands out in the world of portable cooling solutions. Designed to cater to personal and small space environments, it offers a plethora of features and technologies that enhance its performance while ensuring user convenience.

One of the key characteristics of the CV-P09FR is its powerful yet quiet operation. With a cooling capacity of 9,000 BTU, it effectively cools rooms up to approximately 30 square meters, making it suitable for bedrooms, living rooms, and even office spaces. This model operates at a low noise level, allowing users to enjoy a pleasant atmosphere without the distraction of excessive sound.

The Sharp CV-P09FR is equipped with advanced air purification technology, ensuring that the air circulated within the room is clean and healthy. It features a built-in air filter that captures dust, allergens, and other particulate matter, providing not only comfort from heat but also a fresh and breathable environment. This air purification system makes it an excellent choice for allergy sufferers and individuals concerned about air quality.

Mobility and ease of use are integral to the design of the CV-P09FR. This portable air conditioner comes with smooth-rolling caster wheels and a lightweight construction, enabling users to effortlessly move it from one room to another. The installation process is also user-friendly, requiring minimal effort, as it comes with a convenient window installation kit.

Energy efficiency is another strong point for the Sharp CV-P09FR. It operates with a low energy consumption rate, which is beneficial for those looking to reduce their environmental footprint while also keeping electricity bills in check. Its eco-friendly refrigerant further enhances its appeal to environmentally conscious users.

Additionally, the CV-P09FR features multiple cooling modes and fan speeds, allowing users to customize their comfort levels according to personal preferences and changing weather conditions. The remote control functionality adds an extra layer of convenience, giving users the ability to adjust settings from a distance.

In summary, the Sharp CV-P09FR combines portability, powerful cooling performance, air purification, and energy efficiency in a single unit. Its thoughtful design and array of features make it a reliable choice for individuals seeking an effective solution to combat heat while maintaining air quality and comfort in their living spaces.