Sharp CV-P09FR FAN Mode, Ventilation Mode, Press the Mode button to select FAN mode

Page 13

FAN MODE

In this mode, the air conditioner simply circulates the air without cooling it.

Install the exhaust hose (See Page 8), turn the drainage nozzle to the CLOSE position, and check the drainage nozzle is covered with the stopcock.

1 Press the MODE button to select FAN mode.

COOL DEHUM FAN VENT

22 Press the ON/OFF button to start operation.

The red OPERATION lamp ( ) on the unit will light.

• The temperature cannot be set.

1

3

speed.Press the FAN button to set the desired fan

 

QUIET

LOW

HIGH

3

 

 

 

 

TO TURN OFF

Press the ON/OFF button again.

The red OPERATION lamp ( ) on the unit will turn off.

VENTILATION MODE

In this mode, the air conditioner ventilates the air to outdoors.

Install the exhaust hose (See Page 8), turn the drainage nozzle to the CLOSE position, and check the drainage nozzle is covered with the stopcock.

1 Press the MODE button to select VENT mode.

COOL DEHUM FAN VENT

22 Press the ON/OFF button to start operation.

The red OPERATION lamp ( ) on the unit will light.

 

The temperature cannot be

set.

 

3

speed.Press the FAN button to set the desired fan

1

Although the louvers are closed and no air blows out

3

 

into the room, the external ventilation fan speed

 

 

changes.

 

 

 

 

 

QUIET

LOW

HIGH

TO TURN OFF

Press the ON/OFF button again.

The red OPERATION lamp ( ) on the unit will turn off.

ENGLISH

E-11

Image 13
Contents CV P09FR Other Countries outside the EU Important Safety Instructions ContentsOperating Conditions Usage CautionsIncluded LocationEnergy Efficiency Tips Front View Part NamesRear View Remote Control Display Remote ControlLoading Batteries Use two AAA R03 batteries Using the Remote ControlHOW to USE the Remote Control Attach the insect guard net to the ex- haust adapter Installation and Removal of Exhaust HoseAttach the Exhaust adapter to the exhaust hose Attach the exhaust hose adapter to the unitPress the Temperature button to set the desired temperature Cool ModePress the ON/OFF button to start op- eration Press the FAN button to set the de- sired fan speedPress the Mode button to select DEHU- Midification mode Dehumidification ModePresstion. the ON/OFF button to start opera Ventilation Mode FAN ModePress the Mode button to select FAN mode Press the Mode button to select Vent modeTo Change AIR Flow Direction Press the Swing button on the remote controlUP/DOWN AIR Flow Direction LEFT/RIGHT AIR Flow DirectionPress the Cancel button ONE-HOUR OFF TimerTurbo Cool Operation Press the Turbo Cool button againOFF Timer Timer OperationPress the OFF Timer Time as desiredPress the on Timer button On TimerPlasmacluster Operation Auxiliary ModePress the Plasmacluster button again Press the AUX. button againPress the AUX. button on the unit twice DrainageTurn the drainage nozzle to the Close position Replace the stopcock to the drainpipe nozzleCleaning the Filters MaintenanceCleaning the Unit and the Remote Control Cleaning the Insect Guard NETAIR Conditioner does not Operate AT ALL Before Calling for ServiceSharp Corporation

CV-P09FR specifications

The Sharp CV-P09FR is a compact, energy-efficient air conditioner that stands out in the world of portable cooling solutions. Designed to cater to personal and small space environments, it offers a plethora of features and technologies that enhance its performance while ensuring user convenience.

One of the key characteristics of the CV-P09FR is its powerful yet quiet operation. With a cooling capacity of 9,000 BTU, it effectively cools rooms up to approximately 30 square meters, making it suitable for bedrooms, living rooms, and even office spaces. This model operates at a low noise level, allowing users to enjoy a pleasant atmosphere without the distraction of excessive sound.

The Sharp CV-P09FR is equipped with advanced air purification technology, ensuring that the air circulated within the room is clean and healthy. It features a built-in air filter that captures dust, allergens, and other particulate matter, providing not only comfort from heat but also a fresh and breathable environment. This air purification system makes it an excellent choice for allergy sufferers and individuals concerned about air quality.

Mobility and ease of use are integral to the design of the CV-P09FR. This portable air conditioner comes with smooth-rolling caster wheels and a lightweight construction, enabling users to effortlessly move it from one room to another. The installation process is also user-friendly, requiring minimal effort, as it comes with a convenient window installation kit.

Energy efficiency is another strong point for the Sharp CV-P09FR. It operates with a low energy consumption rate, which is beneficial for those looking to reduce their environmental footprint while also keeping electricity bills in check. Its eco-friendly refrigerant further enhances its appeal to environmentally conscious users.

Additionally, the CV-P09FR features multiple cooling modes and fan speeds, allowing users to customize their comfort levels according to personal preferences and changing weather conditions. The remote control functionality adds an extra layer of convenience, giving users the ability to adjust settings from a distance.

In summary, the Sharp CV-P09FR combines portability, powerful cooling performance, air purification, and energy efficiency in a single unit. Its thoughtful design and array of features make it a reliable choice for individuals seeking an effective solution to combat heat while maintaining air quality and comfort in their living spaces.