Sharp CV-P09FR Before Calling for Service, AIR Conditioner does not Operate AT ALL

Page 21

BEFORE CALLING FOR SERVICE

If the unit appears to be malfunctioning, check the following points before calling for a service.

AIR CONDITIONER DOES NOT OPERATE AT ALL

Is the unit plugged in or is the plug loose?

Has the fuse blown or is the circuit breaker tripped?

Did you restart the unit within 3 minutes of a power failure?

If the power was off for less than 3 minutes when, you restarted the air conditioner, a protective device may cause the compressor to shut off, preventing cooling for about 5 minutes.

Are the OPERATION ( ), TIMER ( ) and TURBO COOL ( ) lamps blinking? The water tank inside the unit is full. It must be drained. (See page 17)

AIR CONDITIONER DOES NOT COOL PROPERLY

Is it set to FAN, DEHUMIDIFICATION or VENTILATION mode?

Cooling does not take place in these modes. Change the MODE setting.

Are the filters clogged with dust? Clean and replace the filters.

Is the cooling coil frozen?

No air will blow out if the cooling coil is frozen.

Run the air conditioner in FAN mode with the fan speed set to “HIGH” until all ice dissipates.

Is the temperature set properly?

Is the window exposed to direct sunlight?

Close the curtains or blinds to minimize solar energy heating the room.

Is the exhaust hose too long?

For efficient operation, make the hose as short as possible. The exhaust hose must not be twisted or bent.

SOUNDS

The unit may seem rather loud for the first 2 to 3 minutes when the unit is turned on. This is the sound of the compressor starting-up and is perfectly normal.

A soft, swishing noise can be heard immediately after the unit is turned on or off, and also during operation. This is the sound of the refrigerant flowing inside the unit.

A low buzzing noise is emitted when the unit is generating Plasmacluster ions.

This air conditioner evaporates water condensed during cooling operation within the unit through the exhaust air outlet. Although water flowing sound way be heard, this is normal.

An audible gurgling sound may be heard for about a minute upon starting AUXILIARY mode. This is sound of running drainage pump inside the unit.

An audible gurgling sound may be heard when the unit is operated on a gently sloping floor. Place the unit on a level floor.

TIMER DOES NOT WORK PROPERLY

If a power failure occurs while the TIMER is set, the TIMER setting will be cancelled and will not be retrieved even after the power is restored. This is normal for this unit.

THE UNIT FAILS TO REACT TO THE REMOTE CONTROL SIGNAL

Check the batteries in the remote control. Replace if necessary.

Try to send the signal again with the remote control pointed directly at the unit’s signal receiver window.

Check whether the remote control batteries are installed with the polarities properly aligned.

THE DISCHARGED AIR HAS AN ODOR

This is the smell of ozone generated from the Plasmacluster Ion generator. The ozone concentra- tion is very small, posing no adverse effect on your health. The ozone discharged into the air rapidly decomposes, and its density in the room will not increase.

ENGLISH

E-19

Image 21
Contents CV P09FR Other Countries outside the EU Important Safety Instructions ContentsOperating Conditions Usage CautionsLocation IncludedEnergy Efficiency Tips Part Names Front ViewRear View Remote Control Display Remote ControlLoading Batteries Use two AAA R03 batteries Using the Remote ControlHOW to USE the Remote Control Attach the insect guard net to the ex- haust adapter Installation and Removal of Exhaust HoseAttach the Exhaust adapter to the exhaust hose Attach the exhaust hose adapter to the unitPress the Temperature button to set the desired temperature Cool ModePress the ON/OFF button to start op- eration Press the FAN button to set the de- sired fan speedDehumidification Mode Press the Mode button to select DEHU- Midification modePresstion. the ON/OFF button to start opera Ventilation Mode FAN ModePress the Mode button to select FAN mode Press the Mode button to select Vent modeTo Change AIR Flow Direction Press the Swing button on the remote controlUP/DOWN AIR Flow Direction LEFT/RIGHT AIR Flow DirectionPress the Cancel button ONE-HOUR OFF TimerTurbo Cool Operation Press the Turbo Cool button againOFF Timer Timer OperationPress the OFF Timer Time as desiredPress the on Timer button On TimerPlasmacluster Operation Auxiliary ModePress the Plasmacluster button again Press the AUX. button againPress the AUX. button on the unit twice DrainageTurn the drainage nozzle to the Close position Replace the stopcock to the drainpipe nozzleCleaning the Filters MaintenanceCleaning the Unit and the Remote Control Cleaning the Insect Guard NETAIR Conditioner does not Operate AT ALL Before Calling for ServiceSharp Corporation

CV-P09FR specifications

The Sharp CV-P09FR is a compact, energy-efficient air conditioner that stands out in the world of portable cooling solutions. Designed to cater to personal and small space environments, it offers a plethora of features and technologies that enhance its performance while ensuring user convenience.

One of the key characteristics of the CV-P09FR is its powerful yet quiet operation. With a cooling capacity of 9,000 BTU, it effectively cools rooms up to approximately 30 square meters, making it suitable for bedrooms, living rooms, and even office spaces. This model operates at a low noise level, allowing users to enjoy a pleasant atmosphere without the distraction of excessive sound.

The Sharp CV-P09FR is equipped with advanced air purification technology, ensuring that the air circulated within the room is clean and healthy. It features a built-in air filter that captures dust, allergens, and other particulate matter, providing not only comfort from heat but also a fresh and breathable environment. This air purification system makes it an excellent choice for allergy sufferers and individuals concerned about air quality.

Mobility and ease of use are integral to the design of the CV-P09FR. This portable air conditioner comes with smooth-rolling caster wheels and a lightweight construction, enabling users to effortlessly move it from one room to another. The installation process is also user-friendly, requiring minimal effort, as it comes with a convenient window installation kit.

Energy efficiency is another strong point for the Sharp CV-P09FR. It operates with a low energy consumption rate, which is beneficial for those looking to reduce their environmental footprint while also keeping electricity bills in check. Its eco-friendly refrigerant further enhances its appeal to environmentally conscious users.

Additionally, the CV-P09FR features multiple cooling modes and fan speeds, allowing users to customize their comfort levels according to personal preferences and changing weather conditions. The remote control functionality adds an extra layer of convenience, giving users the ability to adjust settings from a distance.

In summary, the Sharp CV-P09FR combines portability, powerful cooling performance, air purification, and energy efficiency in a single unit. Its thoughtful design and array of features make it a reliable choice for individuals seeking an effective solution to combat heat while maintaining air quality and comfort in their living spaces.