Installing the remote management card on ProLiant ML150 G2 servers
1.Remove the access panel.
2.Lay the server on its unexposed side to access the system board.
3.Locate the remote management card connectors on the system board.
4.Install the remote management card in the connectors on the system board.
5.Reinstall the system covers following the
6.Verify BIOS version and switch settings for the card.
To ensure proper operation of the ProLiant ML150 G2
The remote management card switches must be set to factory default settings.
Switch | Setting |
|
|
SW1 | Off |
|
|
SW2 | On |
|
|
SW3 | On |
|
|
SW4 | Off |
|
|
Post-installation procedures
1.Be sure all components are installed according to the
2.Be sure you have not left any loose tools or parts inside the server.
3.Reinstall any expansion boards, peripherals, board covers, and system cables previously removed.
4.Reinstall the system covers.
5.Connect all external cables and the AC power cord to the system.