D/G-04 Installation

NOTE: The numbers in parentheses are the Reference Numbers on the illustrations in the Parts Manual.

Location

Locate the pump as close to the supply source as possible.

Install it in a lighted clean space where it will be easy to inspect and maintain. Allow room for checking the oil level, changing the oil, and removing the pump head (manifold, valve plate and related items).

Mounting

The pump shaft can rotate in either direction.To prevent vibration, securely attach the pump to a rigid base.

On a belt-drive system, align the sheaves accurately; poor alignment wastes horsepower and shortens the belt and bearing life. Make sure the belts are properly tightened, as specified by the belt manufacturer.

On a direct-drive system, align the shafts accurately. Unless otherwise specified by the coupling manufacturer, maximum parallel misalignment should not exceed .015” and angular misalignment should be held to 1 degree maximum. Careful alignment extends life of the coupling, pump, shafts, and support bearings. Consult coupling manufacturer for exact alignment tolerances.

On a close-coupled system, coat the motor shaft liberally with anti-seize.

Important Precautions

Adequate Fluid Supply. To avoid cavitation and premature pump failure, be sure that the pump will have an adequate fluid supply and that the inlet line will not be obstructed. See “Inlet Piping”.

Positive Displacement. This is a positive-displacement pump. To avoid severe system damage if the discharge line ever becomes blocked, install a relief valve downstream from the pump. See “Discharge Piping”.

Safety Guards. Install adequate safety guards over all pulleys, belts, and couplings. Follow all codes and regulations regarding installation and operation of the pumping system.

Shut-Off Valves. Never install shut-off valves between the pump and discharge pressure regulator, or in the regulator bypass line.

Freezing Conditions. Protect the pump from freezing. See also the Maintenance Section.

Consult the Factory for the following situations:

Extreme temperature applications above 160° F (71° C) or below 40° F (4° C)

Pressure feeding of pumps

Viscous or abrasive fluid applications

Chemical compatibility problems

Hot ambient temperatures above 110° F(43° C)

Conditions where pump oil may exceed 200° F (93° C) because of a combination of hot ambient temperatures, hot fluid temperature, and full horsepower load — an oil cooler may be required

5

D04-991-2400 5/1/04

Image 5
Contents Models D-04, G-04 04 Specifications 04 ContentsDry Lift PerformanceNet Positive Suction Head NPSHr 04 Models with Metallic Pumping Head 04 DimensionsImportant Precautions 04 InstallationLocation MountingInlet Calculations Inlet Piping Suction FeedInlet Piping Pressure Feed Friction Losses Discharge PipingNet Positive Suction Head Hose and RoutingBefore Initial Start-Up Initial Start-Up ProcedureShutdown Procedure During Freezing Temperatures 04 MaintenanceDaily PeriodicallyRef. No 04 Service Fluid EndBolt Torque Specifications Inspect Valves Tools and SuppliesRemove Manifold 3 and Valve Plate Flush Contaminant from Hydraulic End Inspect and Replace DiaphragmsPrime the Hydraulic Cells Only if a diaphragm has rupturedReinstall Valve Plate 12 and Manifold 04 Service Hydraulic End Disassemble Pistons Remove Pump HousingReassemble Pistons Remove and Replace PistonsReinstall Diaphragms Reassemble Housing and Back CoverReplace Shaft Seal Reassemble Pump04 Troubleshooting Premature Failure of Valve Spring or Retainer Valve WearLoss of Oil Limited Warranty Wanner ENGINEERING, INC