D/G-04 Installation
NOTE: The numbers in parentheses are the Reference Numbers on the illustrations in the Parts Manual.
Location
Locate the pump as close to the supply source as possible.
Install it in a lighted clean space where it will be easy to inspect and maintain. Allow room for checking the oil level, changing the oil, and removing the pump head (manifold, valve plate and related items).
Mounting
The pump shaft can rotate in either direction.To prevent vibration, securely attach the pump to a rigid base.
On a
On a
On a
Important Precautions
Adequate Fluid Supply. To avoid cavitation and premature pump failure, be sure that the pump will have an adequate fluid supply and that the inlet line will not be obstructed. See “Inlet Piping”.
Positive Displacement. This is a
Safety Guards. Install adequate safety guards over all pulleys, belts, and couplings. Follow all codes and regulations regarding installation and operation of the pumping system.
Freezing Conditions. Protect the pump from freezing. See also the Maintenance Section.
Consult the Factory for the following situations:
•Extreme temperature applications above 160° F (71° C) or below 40° F (4° C)
•Pressure feeding of pumps
•Viscous or abrasive fluid applications
•Chemical compatibility problems
•Hot ambient temperatures above 110° F(43° C)
•Conditions where pump oil may exceed 200° F (93° C) because of a combination of hot ambient temperatures, hot fluid temperature, and full horsepower load — an oil cooler may be required