Enter Primary DNS address in dotted decimal form:

Enter the desired Primary DNS address as a series of four numbers separated by periods (e.g., 0.0.0.0.) followed by Carriage Return .

8.6PASSWORD

By responding to the Enter selection: message at the end of the main configuration menu with " 5" (Password), you can program the DS73 Password. The password is used for security purposes to prevent unauthorized users from connecting to the DS73 and accessing its functions. The DS73 will respond with a menu similar to the following:

Current password: BTA

Enter Password (8 chars max):

Type the desired password up to eight ASCII characters. Press <ENTER> to return to the main configuration menu.

NOTE: The password is case sensitive. Any non-alphanumeric character including <BACKSPACE> and <DELETE> or a password greater than eight characters is interpreted as an input error and you will be prompted to enter the password again.

Terminate the password entry by typing the <ENTER> key. The DS73 will respond with:

Accept password as typed above? (Y/N) :

Press "Y" to accept the new password or "N" to reject it. If you press "N", the DS73 will return to the "Enter Password" prompt. If you type "Y", the DS73 will return to the main configuration menu.

NOTE: It is not necessary to reset the unit for this option to take effect.

5.1.4UNIT RESET

Users can instruct the DS-Serieswith the DS73 Ethernet module, to “reset” by using the Menu Selection Method to reset the unit. Only a user connected to the peripheral module can issue the reset command. Users can also instruct the DS-Seriesto reset by sending the ASCII string “$BTRESET” from the service port. The Unit Reset and $BTRESET commands do not affect any saved configuration parameters that have been changed from the default values.

Important: The Unit Reset command will terminate communications with connected equipment to the M-Series DAC.

You must re-establish communications with the DS-Seriessystem after the unit has been reset. The Unit Reset menu selection is found in the DS73 Module Menu. This Menu is invoked by sending the Attention Character(default

;;;;;) to the DS73 peripheral module five times. The DS73 will respond with a menu similar to the following, if two Serial I/O modules are installed.

5.1.5.5EXIT

11

Image 11
Contents BayTech Manual Publication #U140A126 Page Copyright 1997 by Bay Technical Associates, Inc Table of Contents Error! Bookmark not defined General Information SpecificationsDIAL-IN IP Address Operation Programmable Features IP AddressCabling 10BASE2 Coax Connection 10BASE-T Modular ConnectionPrimary DNS PasswordDS73 Module Configuration GatewayNetwork Cable Connections good Module IP AddressPrimary DNS Unit Reset Logout Getting Started MaintenanceTechnical Support Returns to the Factory15 DS73/DS73TP Eprom Upgrade 16 DS73/DS73TP Mechanical Layout Index XON/XOFF