HP Virtual Connect Firmware manual Issues and workarounds

Page 8

Issue

Unable to change the server profile iSCSI boot setting of iSCSI HBA Connection port 1 if port 2 is configured as PRIMARY

Workaround

Configure port 1 as PRIMARY for iSCSI boot.

Issue

Unable to use LDAP authenticated user to perform VC firmware update when the VC Domain is managed by VCEM and using VCEM Firmware Update Mode

Workaround

Provide local user credentials or use VCEM maintenance mode to perform VC firmware update.

Issue

Making back to back changes on an assigned Server Profile boot mode setting (UEFI/Legacy) without powering up the server could leads to inconsistent boot mode setting

Workaround

Power on server after making server profile boot mode changes.

Issue

In rare occurrences, a VCSU upgrade for an HP VC 20-Port FC Module may fail, and the VCSU log file will show a message similar to “Unable to get module IP address” for HP VC 20-Port FC Module.

Workaround

Reset the affected HP VC 20-Port FC Module using the OA, and then retry the upgrade.

Issue

FIPS: Inconsistent SNMPv3 traps are generated from VCM

Issue

When linked distribution is set to Auto and a new port is added to the fabric, server logins are redistributed within 5 seconds. The link distribution interval setting in VCM has no effect.

Issue

QoS does not take effect when one 40G port sends oversubscribed traffic to 10/20G port.

Issue

A server using an HP FlexFabric 20Gb 2-port 630FLB/630M Adapter and configured to use Ethernet Jumbo frames may experience lower FCoE throughput if server traffic is oversubscribed (more than 20Gb over) on the FlexFabric Adapter port and the server is only reading disks without writing them. This is because the Ethernet traffic consuming excessive bandwidth.

Workaround

Configure the server to use standard 1500 byte MTU frames. Alternatively, ensure that server traffic (FCoE + Ethernet) doesn’t oversubscribe the port bandwidth of 20Gb.

Issue

If a single server is passing FCoE traffic and port monitoring is enabled, the FCoE traffic rate can drop significantly.

Issue

Issues and workarounds 8

Image 8
Contents HP Virtual Connect Release Notes Page Contents Update recommendation Supersedes informationProduct models Operating systemsLanguages EnhancementsVC 4.31 release resolves the following issues FixesIssues and workarounds Issues and workarounds Prerequisites Installation instructions Page V4.20 V4.30 Baseline Firmware Release Set Important notes Important notes Acronyms and abbreviations Related information Documentation feedback
Related manuals
Manual 12 pages 3.47 Kb