The VCM GUI does not redirect to the correct IP after a VC failover.
Workaround
The next failover succeeds without any issues. Refreshing the browser or closing and opening a new session redirects the browser to the correct IP address.
Issue
Errors are received when changing an FCoE network to a different module in a VCEM environment.
Workaround
The customer must revert the changes, and then complete or cancel the domain maintenance mode. If the uplink must be changed to a different module, the customer can delete the existing network, and then
Issue
Under certain circumstances, the checkpoint status icon in the GUI persists for a long time and is not cleared. The CLI also shows a "Checkpoint Status: Invalid" status in the show domain command output. This condition occurs periodically after a VCSU firmware upgrade of the VC module firmware.
Workaround
To resolve this issue, reset VCM on the primary module or reset the primary module using the OA.
Prerequisites
•VC
o Supports the following adapters:
—HP
—HP FlexFabric 10Gb
—HP
—HP FlexFabric 10Gb
—HP NC552m
—HP NC553m 10Gb
—HP FlexFabric 10Gb
—HP
—HP FlexFabric 10Gb
—HP FlexFabric 20Gb
—HP FlexFabric 20Gb
oSupports the following operating systems:
—Windows 2012
—VMware ESXi 5.1 U2, 5.5
—RHEL 5.9 and 5.10
—RHEL 6.4 and 6.5
Prerequisites 9