HP Cluster Test Software manual Cluster Test GUI

Page 8

To start an individual test, select that test's button. Test parameters are on the same row as the test button.

For each of the tests, the run time can be specified in minutes (m), hours (h), or days (d). The default run time of 0 will run the test for one pass. Normally, the default values are good enough and won't need to be changed. However, in a large cluster solution, these values might need to be changed to reduce the load on CPUs or shorten the test time.

When a test is running, all test buttons are disabled (in grey color).

After each test, all nodes in the test are checked for disk and memory errors – the test fails if the error count exceeds the threshold.

The Network: pull-down is at the top of the interface. This is for selecting the cluster interconnect

type: Admin, Interconnect, or Alternate networks. The Admin network can be a GigE or 10GigE network, the Interconnect and Alternate networks may be GigE, InfiniBand, 10GigE, or None, if they have not been configured. For example, if you are testing an InfiniBand-based cluster with one IB connection per node, you will see Admin, and Interconnect-InfiniBand as options in the pull-down. If you are testing a dual-rail IB cluster, you will see Admin, Interconnect-InfiniBand, Alternate-InfiniBand, and Combined-InfiniBand. In this case, Interconnect-InfiniBand will test the first rail, Alternate-InfiniBand will test the second rail, and Combined-InfiniBand will use both rails for testing.

NOTE: Only MPI applications can use both rails for testing; the Ibverbs tests (ib_send_bw, ib_read_bw, etc.) and Netperf will only work on one rail at a time.

The Stop button halts the current test. When no test is running, this button is disabled.

The Test this group only check box allows tests to be run on either a group of nodes or on the whole cluster. If this box is checked, the tests will run on the group of nodes that includes the head node and compute nodes under its control. If this box is unchecked, the tests run on the whole cluster. When there is only one head node in the cluster solution, Test this group only has no effect.

8The Cluster Test GUI

Image 8
Contents HP Cluster Test Administration Guide January Contents Documentation feedback Glossary Index Useful files and directories Utility commandsSample test output CT Image CT Image using a networkVarieties of Cluster Test RPM Cluster Test GUI Starting Cluster TestFiles generated by Cluster Test Running cluster testsCluster Test GUI Running cluster tests Configuration settings Running tests in a batch Using scripts to run tests Running cluster tests Test descriptions CrissCrossMonitoring tests and viewing results Nodes monitoring windowTest output window Monitoring tests and viewing results Performance analysis Test report Checking the InfiniBand fabric Cluster Test toolbar menus Cluster Test toolbar menusFiles generated by accelerator test Accelerator test GUIStarting accelerator tests Verify Running accelerator testsGPU detection Sgemm Single Precision General Matrix Multiply Test Dgemm Double Precision General Matrix Multiply TestBandWidth GPU Bandwidth Test Memory TestNvidia Linpack Cuda Accelerated Linpack Benchmark Additional software Cluster Test procedure as recommended by HPConfiguring Cluster Test when using RPM Accelerator test procedure Cluster Test procedure as recommended by HP Cluster Test procedure # checkadm Cluster Test procedure Cluster Test procedure as recommended by HP Performance monitor Performance monitor utilityPerformance Monitor toolbar menu Xperf utility Firmware Summary Cluster Test toolsHardware Inventory Server health check Excluding the head node from tests Disk Scrubber Cluster Test tools Running tests in parallel An example cloned per-node directory Creating and changing per node filesAn example per-node directory NFS performance tuning NfsTroubleshooting Detecting new hardwareTroubleshooting Cluster Test Cluster Test Troubleshooting GuideSupport and other resources Scope of this documentIntended audience Contacting HPNew and changed information in this edition Related informationDocumentation WebsitesTypographic conventions Customer self repairCustomer self repair Useful files and directories Cluster Test Useful Files and DirectoriesUtility commands AnalyzeConrep Files generated by ibfabriccheck Inspectibfabric.pl Inspectibfabric.pl Utility commands Ipmitool Pdsh Sample test output CrissCrossSample test output Test4 Pallas Mpibyte Sample test output Stream Node24 Triad 3078.7949 3355 3488 3536 Disk Test CPULinpack UTKPassed Passed Passed Documentation feedback Glossary CMUIndex MPI Accelerator
Related manuals
Manual 25 pages 60.17 Kb