Soleus Air KFHHP-22-ID, KFHHP-22-OD installation manual Test Operation and Check after Installation

Page 23

Test Operation and Check after Installation

Test Operation

1.Test Operation

(1)Do not switch on power before installation is finished completely.

(2)Electric wiring must be connected correctly and securely

(3)Cut-off valves of the connection pipes should be opened.

(4)All the impurities such as scraps must be cleared from the unit.

2.Test Operation Method

(1)Switch on power and press “ON/OFF” button on the remote control to run the air conditioner.

(2)Press “MODE” button and check the operation condition of COOL, HEAT, SWING mode and so forth.

If Wireless remote control is lost, open the surface panel and operate as following:

a.When turning it to Auto position, unit will run in Auto mode, if there is remote control signal, it will run at the remote control signal.

b.When turning it to Test position, the main unit will enter into Cool mode, indoor fan will run at high fan speed, if there is remote control signal, main unit will run at the remote control signal.

c.When turning it to Run position, the main unit will run at received remote control order.

d.When turning it to Stop position, the unit will stop running.

Check after Installation

Items to be checked

Possible Malfunction

 

 

Has it been properly mounted?

The unit may drop, shake or emit noise.

 

 

Have you done the refrigerant leakage test?

It may cause insufficient cooling (heating) capacity.

 

 

Does the unit drain well?

It may cause condensation and dripping.

 

 

Is the voltage in accordance with the rated voltage

It may cause electric malfunction or damage the part.

marked on the nameplate?

 

Is the electric wiring and piping connection

It may cause electric malfunction or damage the unit.

installed correctly and securely?

 

Has the unit been connected to secure grounding

It may cause electrical leakage.

connection?

 

Has the inlet and outlet been insulated?

It may cause insufficient cooling (heating) capacity.

 

 

Has the length of connection pipes and refrigerant

The refrigerant capacity is not accurate.

capacity been recorded?

 

- 21 -

Image 23
Contents Indoor Unit Outdoor Unit Wall Mounted Mini Split Heat Pump Air ConditionerTable of Contents Carefully read the following instructions before use Instructions before UseInstructions before Use Description of Air Conditioner Components Function-Remote control Remote Control OperationRemote Control Operation General Procedure How to Insert BatteriesUser Notices Washing Care and MaintenanceCheck before Use Trouble ShootingProblem Trouble ShootingTrouble Shooting KFHHP-22-ID / KFHHP-22-OD Specifications and Technical DataInstallation Diagram Installation ServicesOutdoor Unit Installation LocationIndoor Unit Install the drainage hose InstallationInstall the rear panel Install the piping holeOperation Procedures Wiring of indoor unitWire Electric WiringWiring of Outdoor unit Install the Indoor Unit Install the Power LineInstall the connection pipe Install the Outdoor UnitAir Purging and Leakage Test Test Operation Test Operation and Check after InstallationElectrical Schematic Diagram Indoor Unit Electrical Schematic Diagram Outdoor Unit Warranty

KFHHP-22-ID, KFHHP-22-OD specifications

The Soleus Air KFHHP-22-OD and KFHHP-22-ID are two innovative cooling and heating solutions designed to offer efficient climate control for both domestic and commercial spaces. These models are part of Soleus Air's commitment to delivering high-quality, energy-efficient products that cater to diverse environmental needs.

A standout feature of both models is their versatile functionality, providing not just cooling but also heating capabilities. This dual functionality makes them ideal for year-round use, ensuring comfort in varying temperatures, which is particularly beneficial in regions with extreme climate conditions.

In terms of design, both the KFHHP-22-OD and KFHHP-22-ID units are compact and modern, ensuring they fit seamlessly into any space. The sleek appearance is complemented by user-friendly controls that facilitate easy operation. The convenience of remote control operation further enhances user experience, allowing adjustments from anywhere in the room.

One of the most notable technologies featured in these units is the advanced inverter technology, which optimizes energy consumption by adjusting the compressor speed based on the cooling or heating demand. This not only contributes to significant energy savings but also helps maintain a consistent temperature, providing enhanced comfort.

Noise reduction is another critical aspect that Soleus Air has prioritized in the KFHHP-22 models. Both units operate quietly, ensuring that they do not disrupt the peace of your environment, whether it be at home or in a professional setting. This makes them suitable for bedrooms, offices, or any quiet space where noise can be a concern.

Installation and maintenance are simplified thanks to the design of these units. The easy-to-follow installation manual means that users can set them up with minimal hassle. Additionally, regular maintenance is streamlined, allowing users to enjoy prolonged performance and efficiency.

Another characteristic worth mentioning is their effectiveness in dehumidifying the air. This is particularly advantageous in humid climates, as it not only improves comfort levels but also helps prevent mold and mildew growth.

In summary, the Soleus Air KFHHP-22-OD and KFHHP-22-ID models stand out for their energy efficiency, dual functionality, modern design, quiet operation, and ease of use. With advanced technologies that enhance comfort and control, they represent a smart investment for anyone seeking reliable and versatile climate control solutions.