HP Panter 2Tier manual Filename No such file or directory

Page 83

Prolifics Installation Error Messages

Windows: Set the variable to win in PROL4W32.INI.

If you are running in character mode and the screen appears disorganized, with all the text bunched together along with special characters, check the value of SMTERM; you probably only need to change its value, but you may also need to create a new video file.

Filename: No such file or directory

Cause: The filename in brackets is specified as the value of the SMVIDEO, SMKEY, SMMSGS, or some similar configuration variable in the environment or in smvars.bin, but the file could not be found.

Action: Correct the name, and use the full pathname of the file. If you correct it in smvars, recompile smvars with the var2bin utility.

[Variable]: Environment variable missing

Cause: Prolifics could not find an entry for the cited variable in SMVARS or in the environment (refer to the following note). This error usually means that you have some variables defined in your environment, but not all that are required, and SMVARS is not defined.

Note: Most Prolifics setup variables can be set in the environment, rather than depending on values set in an SMVARS-defined file. If Prolifics can’t find a required variable specification in either the environment or in the SMVARS file, that variable will be cited as missing. Refer to the Configuration Guide for more details.

SMVARS: Bad file format

Cause: SMVARS is set to be the name of an existing file, but it is not a binary SMVARS file. The most common incorrect value for SMVARS in this case is the path and name of the source SMVARS file instead of the binary SMVARS file.

Action: Point to the binary file that has the .bin extension.

SMVARS: Environment variable missing

Cause: SMBASE (or SMVARS, if you are using one) is not set, or not set properly. Normally, Prolifics looks for smvars.bin in the config directory under the directory pointed to by SMBASE. If SMBASE is not set, you must have an SMVARS variable to tell Prolifics explicitly where the SMVARS file can be found. If SMBASE is not set properly, and Prolifics cannot find an SMVARS variable, the above message is given.

Action: Correct (or set) the SMBASE variable specification, or determine why setting it is not taking effect.

Windows: Check to see that SMBASE is being set in autoexec.bat and that you have not run out of environment space.

78

2-Tier Installation

Image 83
Contents Tier Installation Page Table of Contents Chapter Web Application Server Windows Appendix D License File Organization of this Guide About this GuideKeyboard Conventions ConventionsText Conventions Panther Documentation Panther Documentation Online Documentation Procedure or module Collateral Documentation Additional Help Page Post-Installation Installation ChecklistPre-Installation InstallationGeneral Information Contents of the Installation PackageApplication Architecture Which Panther Components to Install?For More Information Hardware and Software Requirements Client Windows InstallationClient Pre-Installation for Windows Upgrading To run the setup program Client Installation for WindowsInstallation Procedure Informix Installing a Database DriverTo install database drivers Oracle Microsoft SQL ServerSybase To create a new Prolifics executable Client Post-Installation for WindowsPost-Installation Overview Create New Prolifics ExecutablesSpecifying Executables For each Windows client Configure the Client EnvironmentLinking Database To include the appropriate database in your executablesLook at Sample Applications Verify the InstallationTroubleshooting Client InstallationOnline Help Manuals Adding Panther Documents Windows Path SettingsWeb Application Server Windows Web Application Server Pre-Installation for WindowsBefore Installing Obtaining a Permanent License File Web Application Server Post-Installation for WindowsLicensing for Prolifics Web Application Server To obtain the license file Installing the License FileTo install a permanent license file Location License File Configure the Web Application Server EnvironmentCreating a Web Application Web Application Server InstallationTo verify the Prolifics web application server installation Prolifics Gallery web application Look at SamplesQuickStart Client Pre-Installation for Unix Client Unix InstallationImplement File Protection File Ownership and ProtectionUpgrading Determine File LocationTo install Panther from a CD-ROM Client Installation for UnixTo configure the installation Configuring the InstallationAdditional Procedures Licensing for Prolifics Client Post-Installation for UnixInstalling License File To start the license manager Location of the License File Starting ManagerTo determine the version of lmgrd Create New Prolifics Executables Specifying Executables Linking in the Database Configure the Client Environment ApplicationDir/setup.sh Look at a Sample Application To verify a Unix client installationMotif Version Number Graph Functionality Post-Installation NotesImplementing Character-Mode Utilities License Manager.ebtrc file $SMBASE/docs = Panther Web Application Server Unix Web Application Server Pre-Installation for UnixPreliminary Steps Web Application Server Post-Installation for UnixWeb Application Server Unix Determine File Locations Creating Your Web ApplicationMonitor -start applicationName DLLs for Jpeg Decoding WindowsEnvironment Space Visual C++ Floating-Point Options Using Prolifics Utilities` Run the utilities from DOS For Windows 95/98 and Windows NT Initialization DatabasesFor Windows 95/98 For Windows NT Driver=ora8dmnt.dll License Administration Types Daemons Licensing in ProlificsLicense Daemons and License Types License Types Options FileContents Options File Example FLEXlm UtilitiesPerforms a checksum of a license file LmcksumLmdiag Diagnoses licensing problemsTakes down license daemons LmdownStarts up the license manager daemon LmgrdOutput from lmhostid is similar to the following LmhostidRemoves a user license and returns it to the license pool LmremoveTells the license daemon to reread the license file LmrereadLmstat Reports status on license manager daemons and feature usageLmswitchr Reports the FLEXlm version of a library or binary LmverLicense File Contents of the License FileDaemon Increment Prolifics Installation Error Messages Error MessagesFilename No such file or directory Microsoft SQL Server-Specific Messages DLL MessagesInformix-Specific Messages Oracle-Specific Messages ODBC-Specific MessagesDLL Version Mismatch Messages License Manager Error MessagesGraph-Related Messages Sybase-Specific MessagesAll License Types Prolifics License-Related MessagesProlifics License Manager Initialization failed Node-locked Licenses Floating LicensesCreate License Utility FLEXlm Informational Messages Cause feature has passed its expiration dateCause License daemon received fatal signal nnn FLEXlm Configuration Problem Messages Daemon Software Error Messages Cause An invalid server connect message was received Cause An error in a read system call was detected Index Tier Installation Odbc