HP E4446A, E4448A Presetting the Spectrum Analyzer, Creating a User Preset, Disabling User Preset

Page 36

Making a Basic Measurement

Presetting the Spectrum Analyzer

Presetting the Spectrum Analyzer

Preset provides a known starting point for making measurements. The analyzer has three types of preset:

Factory Preset Restores the analyzer to its factory-defined state.

User Preset Restores the analyzer to a user-defined state.

Mode Preset This type of preset restores the currently selected mode to a known state.

For details, see the User’s/Programmer’s manual.

When Preset Type is set to Factory, pressing the green Preset key triggers a factory preset. When Preset Type is set to User, pressing Preset displays the softkeys Factory Preset, User Preset, and Mode Preset (if applicable); you then select the preset you want. If Preset Type is set to Mode, but a personality is not installed, pressing Preset triggers a factory preset.

Creating a User Preset

If you constantly use settings which are not the factory defaults, use the following steps to create a user-defined preset:

1.Set analyzer parameters as desired.

2.Press System, Power On/Preset, Save User Preset to set the current parameters as the user preset state.

3.Press Preset to select User in the same softkey menu to enable user preset as an option.

Disabling User Preset

Go to the Power On/Preset menu (press System, Power On/Preset) and select a Preset Type of Factory or Mode.

36

Chapter 3

Image 36
Contents Getting Started Guide Additional Information Contents Case of Difficulty Installation and Setup Agilent Technologies Performance Spectrum Analyzer PSA Accessories Initial InspectionDescription Standard Documentation SetIf There Is a Problem Power Requirements AC Power Cord Description SpecificationsAC Power Cords Battery Information Turning on the Analyzer for the First Time Information ScreenWhy Aren’t All the Personality Options Loaded in Memory? Using an External ReferenceFirmware Revision TIPRunning Internal Alignments Manually Performing an AlignmentPrinter Setup and Operation EquipmentPrinter Models Interconnection and Setup Testing Printer OperationProtecting Against Electrostatic Discharge Test Equipment and ESDAdditional Information about ESD Safety Information Front and Rear Panel Features Front-Panel Connectors and Keys Front Panel OverviewName Description Name Display Annotations Description Associated Function KeysTrigger & sweep modes Trace modes Phase noise optimizationa Rear-Panel Features Always turn off power before plugging in keyboard Key Overview Key Overview Front and Rear Panel Symbols Front and Rear Panel Symbols Making a Basic Measurement Basic Assumption Using the Front Panel Using Menu KeysEntering Data Knob Arrow Keys Numeric Keypad Unit Softkeys Enter KeyPresetting the Spectrum Analyzer Creating a User PresetDisabling User Preset Viewing a Signal Setting Reference Level and Center Frequency10 MHz Internal Reference Signal and Associated Spectrum Setting Frequency SpanReading Frequency & Amplitude Changing Reference LevelA Marker on the 10 MHz Peak Improving Frequency Accuracy Valid Marker Count RangeIncreasing Marker Frequency Accuracy Viewing Catalogs and Saving Files Viewing Catalogs and Saving Files File Menu Functions Locating and viewing files in the catalogCatalog Menu Creating a directory Set up the analyzer trace Saving a FileViewing Traces 1 Save the file Viewing Traces 1, 2,Saving a File Loading a file File LoadedVerifying Trace Renaming a File Renaming a FileCopying a File Put a formatted floppy in the a driveDeleting a File Using the Alpha Editor Using the Alpha Editor Options and Accessories Ordering Options and Accessories Accessories seeOptions see Options Option Name Description Number124 ANE BAB Name Description UK6Accessories Gpib Cable USB/GPIB CableHP/Agilent 11970 Series Harmonic Mixers Static Safe Accessories HP/Agilent 11974 Series Preselected Millimeter MixersRF and Transient Limiters Case of Difficulty Personnel. To prevent electrical shock, do not remove covers Types of Spectrum Analyzer Messages Types of MessagesBefore Calling Agilent Technologies Check the BasicsReference, 10 MHz to select On Read the Warranty Service OptionsCalling Agilent Technologies United States Latin America New Zealand Canada Japan Asia PacificEurope Australia Returning an Analyzer for Service Service TagOriginal Packaging Other PackagingReturning an Analyzer for Service Returning an Analyzer for Service Index NumericsIndex-80

E4443A, E4448A, E4445A, E4446A, E4440A specifications

The HP E4440A, E4446A, E4445A, E4448A, and E4443A are high-performance spectrum analyzers designed to meet the testing and measurement needs of engineers and technicians in various industries. These models offer a combination of advanced technologies and features that enhance their functionality and usability.

Starting with the HP E4440A, this spectrum analyzer is well-known for its wide frequency range and excellent resolution bandwidth, making it ideal for characterizing RF signals. It is capable of analyzing signals from 9 kHz up to 1.5 GHz, providing a comprehensive tool for capturing a wide spectrum of frequencies. The E4440A features a sophisticated built-in signal analysis capability, including demodulation and specialized measurement functions that assist in the evaluation of complex signals.

The E4446A elevates performance further with a frequency range extending up to 6 GHz. This model includes advanced phase noise measurement capabilities, which are crucial for testing communication systems and ensuring signal integrity. Its large color display coupled with a user-friendly interface allows for easy navigation through various measurement settings.

For deeper insights into signal behavior, the HP E4445A stands out with its ability to perform real-time spectrum analysis. This feature allows engineers to capture transient signals and analyze them effectively, which is essential in modern RF design and troubleshooting. The E4445A also supports a range of modulation analysis tools enabling comprehensive testing of communication systems.

Meanwhile, the E4448A is recognized for its high dynamic range and low noise floor. These characteristics are essential for analyzing weak signals in the presence of stronger ones. Its enhanced sensitivity allows engineers to detect signals buried in noise, which is vital for applications such as spectrum monitoring and interference analysis.

Finally, the HP E4443A is tailored for more specialized applications, featuring a frequency range up to 3 GHz. It incorporates advanced digital signal processing techniques that facilitate accurate measurements even in challenging environments. Its portability and robust design make it a preferred choice for field applications, allowing users to perform spectrum analysis where needed.

In summary, the HP E4440A, E4446A, E4445A, E4448A, and E4443A spectrum analyzers offer a rich set of features and technologies that cater to the evolving demands of RF engineers. With their superior performance characteristics, they serve as invaluable tools across a variety of testing and measurement applications in the telecommunications and electronics sectors.