HP E4445A manual HP/Agilent 11974 Series Preselected Millimeter Mixers, RF and Transient Limiters

Page 68

Options and Accessories

Accessories

HP/Agilent 11974 Series Preselected Millimeter Mixers

11974 Series preselected millimeter mixers are available to extend the frequency range of analyzers with Option AYZ (external mixing) up to 75 GHz. Preselection reduces mixer overload from broadband signals, reduces radiation of local oscillator harmonics back to the device under test, and reduces the level of image and multiple responses displayed. The following four models are available:

Table 5-2.

HP/Agilent Model

Frequency Range

Number

 

 

 

11974A

26.5 to 40.0 GHz

 

 

11974Q

33.0 to 50.0 GHz

 

 

11974U

40.0 to 60.0 GHz

 

 

11974V

50.0 to 75.0 GHz

 

 

RF and Transient Limiters

The Agilent 11867A and 11693A RF Limiters protect the analyzer input circuits from damage due to high power levels. The 11867A operates over a frequency range of dc to 1800 MHz and begins reflecting signal levels over 1 mW up to 10 W average power and 100 watts peak power. The 11693A microwave limiter (0.1 to 12.4 GHz, usable to 18 GHz) guards against input signals over 1 milliwatt up to 1 watt average power and 10 watts peak power.

The Agilent 11947A Transient Limiter protects the analyzer input circuits from damage due to signal transients. It specifically is needed for use with a line impedance stabilization network (LISN). It operates over a frequency range of 9 kHz to 200 MHz, with 10 dB of insertion loss.

Static Safe Accessories

9300-0797 3M static control mat 0.6 m × 1.2 m (2 ft. × 4 ft.) with a 4.6 cm (15 ft.) ground wire. Does not include wrist strap or cord

9300-1367 Wrist-strap, color black, stainless steel. Four adjustable links and a 7 mm post-type connection.

9300-0980 Wrist-strap cord 1.5 m (5 ft.)

9300-1308 ESD heel-strap (reusable 6 to 12 months)

68

Chapter 5

Image 68
Contents Getting Started Guide Additional Information Contents Case of Difficulty Installation and Setup Agilent Technologies Performance Spectrum Analyzer PSA Accessories Initial InspectionDescription Standard Documentation SetIf There Is a Problem Power Requirements AC Power Cord Description SpecificationsAC Power Cords Battery Information Turning on the Analyzer for the First Time Information ScreenWhy Aren’t All the Personality Options Loaded in Memory? Using an External ReferenceFirmware Revision TIPRunning Internal Alignments Manually Performing an AlignmentPrinter Models Printer Setup and OperationEquipment Interconnection and Setup Testing Printer OperationAdditional Information about ESD Protecting Against Electrostatic DischargeTest Equipment and ESD Safety Information Front and Rear Panel Features Name Front-Panel Connectors and KeysFront Panel Overview Description Name Display Annotations Description Associated Function KeysTrigger & sweep modes Trace modes Phase noise optimizationa Rear-Panel Features Always turn off power before plugging in keyboard Key Overview Key Overview Front and Rear Panel Symbols Front and Rear Panel Symbols Making a Basic Measurement Basic Assumption Using the Front Panel Using Menu KeysEntering Data Knob Arrow Keys Numeric Keypad Unit Softkeys Enter KeyDisabling User Preset Presetting the Spectrum AnalyzerCreating a User Preset Viewing a Signal Setting Reference Level and Center Frequency10 MHz Internal Reference Signal and Associated Spectrum Setting Frequency SpanReading Frequency & Amplitude Changing Reference LevelA Marker on the 10 MHz Peak Improving Frequency Accuracy Valid Marker Count RangeIncreasing Marker Frequency Accuracy Viewing Catalogs and Saving Files Viewing Catalogs and Saving Files File Menu Functions Locating and viewing files in the catalogCatalog Menu Creating a directory Set up the analyzer trace Saving a FileViewing Traces 1 Save the file Viewing Traces 1, 2,Saving a File Loading a file File LoadedVerifying Trace Renaming a File Renaming a FileCopying a File Put a formatted floppy in the a driveDeleting a File Using the Alpha Editor Using the Alpha Editor Options and Accessories Options see Ordering Options and AccessoriesAccessories see Options Option Name Description Number124 ANE BAB Name Description UK6Accessories HP/Agilent 11970 Series Harmonic Mixers Gpib CableUSB/GPIB Cable RF and Transient Limiters Static Safe AccessoriesHP/Agilent 11974 Series Preselected Millimeter Mixers Case of Difficulty Personnel. To prevent electrical shock, do not remove covers Types of Spectrum Analyzer Messages Types of MessagesBefore Calling Agilent Technologies Check the BasicsReference, 10 MHz to select On Calling Agilent Technologies Read the WarrantyService Options Europe Australia United States Latin America New ZealandCanada Japan Asia Pacific Returning an Analyzer for Service Service TagOriginal Packaging Other PackagingReturning an Analyzer for Service Returning an Analyzer for Service Index NumericsIndex-80

E4443A, E4448A, E4445A, E4446A, E4440A specifications

The HP E4440A, E4446A, E4445A, E4448A, and E4443A are high-performance spectrum analyzers designed to meet the testing and measurement needs of engineers and technicians in various industries. These models offer a combination of advanced technologies and features that enhance their functionality and usability.

Starting with the HP E4440A, this spectrum analyzer is well-known for its wide frequency range and excellent resolution bandwidth, making it ideal for characterizing RF signals. It is capable of analyzing signals from 9 kHz up to 1.5 GHz, providing a comprehensive tool for capturing a wide spectrum of frequencies. The E4440A features a sophisticated built-in signal analysis capability, including demodulation and specialized measurement functions that assist in the evaluation of complex signals.

The E4446A elevates performance further with a frequency range extending up to 6 GHz. This model includes advanced phase noise measurement capabilities, which are crucial for testing communication systems and ensuring signal integrity. Its large color display coupled with a user-friendly interface allows for easy navigation through various measurement settings.

For deeper insights into signal behavior, the HP E4445A stands out with its ability to perform real-time spectrum analysis. This feature allows engineers to capture transient signals and analyze them effectively, which is essential in modern RF design and troubleshooting. The E4445A also supports a range of modulation analysis tools enabling comprehensive testing of communication systems.

Meanwhile, the E4448A is recognized for its high dynamic range and low noise floor. These characteristics are essential for analyzing weak signals in the presence of stronger ones. Its enhanced sensitivity allows engineers to detect signals buried in noise, which is vital for applications such as spectrum monitoring and interference analysis.

Finally, the HP E4443A is tailored for more specialized applications, featuring a frequency range up to 3 GHz. It incorporates advanced digital signal processing techniques that facilitate accurate measurements even in challenging environments. Its portability and robust design make it a preferred choice for field applications, allowing users to perform spectrum analysis where needed.

In summary, the HP E4440A, E4446A, E4445A, E4448A, and E4443A spectrum analyzers offer a rich set of features and technologies that cater to the evolving demands of RF engineers. With their superior performance characteristics, they serve as invaluable tools across a variety of testing and measurement applications in the telecommunications and electronics sectors.