LCDI POWER CORD AND PLUG

LCDI POWER CORD AND PLUG

This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord with no termination on the load side and a LCDI attachment plug on the line side.

The LCDI power cord and plug will remove the supply source via electrical disconnect (circuit trip) if the nominal current leakage between the cord shield and either load conductor exceeds a predetermined value. The cord will remain de-energized until the devise has been manually reset. This is intended to reduce the risk of a fire in the power cord or combustible materials nearby. The cord shields are not grounded and they must be considered a shock hazards if exposed. The cord shield must not be connected to ground or to any exposed metal.

The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly. To test:

1.Plug power cord into wall outlet

2.Press TEST Button, circuit should trip, cutting power to the air conditioner

3.Press RESET button for use

If test button is pressed and unit can still be turned on, current leakage has been detected. Do not use the air conditioner or attempt to reset the LCDI Plug. Contact Soleus Air Customer Service for troubleshooting recommendations.

RESET

TEST

WARNING:

1.DO NOT press the TEST button while the air conditioner is operating.

2.The TEST and RESET buttons should not be used as ONand OFFswitches.

3.The cord and plug are not intended to offer protection to externally connected loads or supply circuits.

4.The cord and plug are intended for indoor use only.

4

Image 4
Contents Portable Air Conditioner and Heater Model No. PH3-12R-03 Reference No. KY2-34With Heat Pump Technology Operating Instructions IMPORTANT INSTRUCTIONS PACKAGE CONTENTS SPECIFICATIONSModel Number PH3-12R-03LCDI POWER CORD AND PLUG RESET TESTFRONT ACCESSORIESBACK SELECTING THE LOCATION INSTALLATIONMOUNTING THE EXHAUST HOSE WINDOW KIT INSTALLATION WINDOW KIT INSTALLATIONWINDOW KIT INSTALLATION cont’d CONTROL PANEL & MULTI-COLORDISPLAY CONTROL PANEL, DISPLAY, & OPERATING INSTRUCTIONSMULTI-COLORDISPLAY OPERATING INSTRUCTIONS CONTROL PANEL BUTTONS Refer to the images on pageAir Conditioner Mode Dehumidifier ModeFan Mode OPERATING THE UNIT USING THE CONTROL PANELHeat Mode Auto ModeEmergency Condensate Holding Tank Compressor IndicatorDRAIN HOLE DRAIN PLUG OPERATING THE UNIT USING THE REMOTE CONTROL REMOTE CONTROL OPERATING INSTRUCTIONSMAINTENANCE WARRANTY One Year Limited WarrantyTHIS WARRANTY DOES NOT COVER For Technical Support and Warranty Service