Specifications
General Specifications |
|
Display | Dual Display; |
Jaw Opening | 1.6” (42mm) |
Max. Input limit | Max. voltage between any terminal and ground: 600Vrms |
Sampling rate | 2.5 times per second (Digital Display); Once every 6 |
| seconds (KW, KVA, and KVAR) |
Auto Sleep | After approx. 30 minutes (feature can be defeated) |
Low battery indication | Battery symbol appears on the LCD |
Power supply | 9V Battery |
Battery life | Approx. 32 hours with alkaline battery |
Operating Temperature | 32 to 122oF (0 to 50oC) |
Operating Humidity | < 80% RH |
Operating Altitude | 7000 ft. (2000 meters) maximum. |
Storage Temperature | 14 to 140oF |
Storage Humidity | < 70% RH |
Temperature coefficient | 0.1 x (specified accuracy) / oC at < 64oF (18oC), > 82oF |
| (28oC) |
Dimensions | 9.0 x 3.0 x 1.5" (228 x 76 x 39mm) |
Weight | Approx. 1.0 lb. (465g) |
Approvals | CE, UL |
Safety | This meter is intended for indoor use and protected, against |
| the users, by double insulation per |
| |
| Degree 2. The meter also meets UL |
UL Listed | The UL mark does not indicate that this product has been |
| evaluated for the accuracy of its readings. |
PER IEC1010 OVERVOLTAGE INSTALLATION CATEGORY
OVERVOLTAGE CATEGORY I
Equipment of OVERVOLTAGE CATEGORY I is equipment for connection to circuits in which measures are taken to limit the transient overvoltages to an appropriate low level. Note – Examples include protected electronic circuits.
OVERVOLTAGE CATEGORY II
Equipment of OVERVOLTAGE CATEGORY II is
Note – Examples include household, office, and laboratory appliances.
OVERVOLTAGE CATEGORY III
Equipment of OVERVOLTAGE CATEGORY III is equipment in fixed installations. Note – Examples include switches in the fixed installation and some equipment for industrial use with permanent connection to the fixed installation.
OVERVOLTAGE CATEGORY IV
Equipment of OVERVOLTAGE CATEGORY IV is for use at the origin of the installation. Note – Examples include electricity meters and primary
17 | 380976 | V3.1 | 6/08 |