HP Extech 380976 manual KVA 3φ 4W, Resistance and Audible Continuity Measurements

Page 13

6.W3φ4W = WR(L1) + WS(L2) WT(L3)

KVA 3φ 4W = KW2 3φ 4W + KVAR 2 3φ 4W

PF3φ 4W = KW 3φ 4W

KVA 3φ 4W

7. Set the rotary switch to another position to exit this mode and clear the stored data.

NOTE

1.The "+" sign printed on meter must face the power source for accurate measurement.

2.If the device under test is switching power supply, the KW, PF and θ readings may not be correct.

NOTE

For 3φ4W power measurements, WR or WS and WT must be positive. If one shows negative power, check the connections.

Resistance and Audible Continuity Measurements

WARNING

Before taking any in-circuit resistance measurements remove power from the circuit under test and discharge all capacitors.

1. Set the rotary switch to the ‘Ω, ’or ‘MΩ’ position.

2. Insert the test leads into the input jacks. (Black to ‘COM’ and Red to ‘Ω’)

3. Connect the test leads to the circuit or component under test.

4. Read the resistance value on the LCD.

5. For measurements < 40Ω, the continuity beeper will sound.

13

380976

V3.1

6/08

Image 13
Contents 1Φ/3Φ 1000 Amp True RMS Power Clamp-On Model Introduction Table of ContentsSafety Information WarrantyWhen servicing, use only specified replacement parts Meter Description AC + DC Voltage Measurements MeasurementsAC Current Measurements 380976 V3.1 380976 V3.1 KVA 3φ 3W KW+PF Power Factor, KW+KVAR, KVA+θPhase Angle or A+V380976 V3.1 380976 V3.1 380976 V3.1 380976 V3.1 Resistance and Audible Continuity Measurements KVA 3φ 4WCapacitance Measurements Temperature MeasurementsDiode Tests AC and DC µA MeasurementsHold MX/MN Key Meter Control KeysRange Key Auto Sleep Disable Automatic Sleep Mode and Battery ReplacementBattery Replacement Specifications AC Current 50Hz to 400Hz True RMS Measurement SpecificationsΜA True RMS AC+DC AC Voltage 50Hz to 400Hz True RMS1Φ/3Φ True Power PF 0.5 or 60o 50/60Hz Temperature K-Type thermocouple1Φ/3Φ Horse Power HP PF 0.5 or 60o 50/60Hz 1Φ/3Φ Reactive Power Kvar PF 0.5 or 60o 50/60Hz1Φ/3Φ Apparent Power KVA Calibration and Repair ServicesPhase Angle 50/60Hz Frequency