HP EX Plus manual Switches HP JetDirect 300X

Page 15

Switches (HP JetDirect 300X and 500X)

The HP JetDirect 300Xand 500X Print Servers have configuration switches that should be used only if the print server fails to link on the network. The factory-default setting of all 3 switches down will suit most installations. These switches only apply to 10Base-T and 100Base-TX networks only.

When the first switch is set to Auto, the other two switch settings are ignored; the server auto-negotiates the link speed and duplex setting with the connected switch or hub device. Even with devices that don’t auto-negotiate, the print server detects the network link speed and uses half duplex.

Although nearly always unnecessary, you can control the settings directly by positioning the switches as shown in the table below, only if you are certain of the duplex setting and speed at which the switch or hub is operating.

If the auto

And if the

And if the

 

switch is

speed switch

duplex switch

Then the

set to...

is set to...

is set to...

settings are...

AUTO

either position

either position

Auto-negotiated

(down)

(default=down)

(default=down)

(factory default)

 

 

 

 

MANUAL

10 (up)

HALF (down)

10Base-T

(up)

 

 

Half-duplex

MANUAL

100 (down)

HALF (down)

100Base-TX

(up)

 

 

Half-duplex

 

 

 

 

MANUAL

10 (up)

FULL (up)

10Base-T

(up)

 

 

Full-duplex

 

 

 

 

MANUAL

100 (down)

FULL (up)

100Base-TX

(up)

 

 

Full-duplex

 

 

 

 

Note

In Auto mode, you can see the network speed being

 

used by checking the LEDs at the RJ-45 connector.

 

See p.1-8.

 

 

1Product Overview

Product Overview 1-9

Image 15
Contents HP JetDirect External Print Servers Page Page Publication number November Applicable Products Contents Page Product Overview Supported Printers, Plotters, and HP All-in-One Peripherals 1Product Overview HP JetDirect 300X J3263A Components and FeaturesProduct Overview Transmission Media Hardware Requirements Status Activity LED is Then the print server is LEDsSwitches HP JetDirect 300X Product Overview Token Ring data-rate switch set at 16 Mpbs on the J3264A Hardware InstallationFollowing steps, the circled numbers Selecting a Configuration Page Language Verifying the Hardware InstallationResetting to Factory Defaults Physical Specifications SpecificationsSpecifications Power RequirementsSpecifications A-3 Electromagnetic Emissions EnvironmentalRegulatory Statements FCC Statement U.S.AEuropean Community Declaration of Conformity Statements Chinese Safety Statement Page 5969-3466