Thermo Products OH6FX072DV4R, OH8FA119DV5R, OH8FA119D60R 1A ECM blower motor speed chart

Page 32

Heating Speed Set-ups

OH8FA119DV5

 

 

 

 

 

 

Furnace Motor Current

 

 

 

 

 

 

 

 

 

Draw (Amps / Watts) vs.

 

 

 

 

 

 

 

 

 

External Static Pressure (in W.C)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low Fire

Med Fire

High Fire

 

 

 

 

 

 

 

 

 

BTUH

101,000

119,000

132,000

 

 

 

 

 

 

 

 

Fan

 

 

 

 

 

 

 

 

 

 

 

 

Control

 

 

 

 

 

 

 

 

 

 

 

 

SW 1

 

 

Aprox.

Aprox.

 

 

 

 

 

 

 

 

Switch

Heating

Aprox.

 

 

 

 

 

 

 

 

Settings

CFM

Rise (F0 )

Rise (F0 )

Rise (F0 )

0.1

0.2

0.3

0.4

0.5

0.6

0.7

 

3-OFF

1202

78o

 

 

1.4/124

1.8/161

2.1/190

2.4/220

2.7/240

3.1/286

3.4/317

 

2-OFF

 

 

 

 

 

 

 

 

 

 

 

 

1-OFF

 

 

 

 

 

 

 

 

 

 

 

 

3-OFF

 

o

o

 

 

 

 

 

 

 

 

 

2-OFF

1315

71

84

 

1.8/158

2.1/190

2.3/209

2.7/250

3.1/285

3.4/311

3.8/356

 

1-ON

 

 

 

 

 

 

 

 

 

 

 

 

3-OFF

 

o

o

 

 

 

 

 

 

 

 

 

2-ON

1429

65

77

 

2.0/185

2.4/220

2.7/251

3.1/284

3.6/330

4.0/370

4.3/408

 

1-OFF

 

 

 

 

 

 

 

 

 

 

 

 

3-OFF

 

o

o

o

 

 

 

 

 

 

 

 

2-ON

1565

60

70

78

2.4/216

2.8/254

3.2/295

3.8/349

4.0/379

4.6/432

4.9/463

 

 

 

 

 

1-ON

 

 

 

 

 

 

 

 

 

 

 

Factory SW1

3-ON

 

 

 

 

 

 

 

 

 

 

 

Switch

1701

o

o

o

3.0/271

3.5/322

3.8/357

4.4/416

4.9/456

5.1/494

5.5/532

Settings

2-OFF

55

65

72

 

 

 

 

 

 

 

 

 

 

 

1-OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3-ON

 

 

o

o

 

 

 

 

 

 

 

 

2-OFF

1860

 

59

66

3.9/363

4.3/410

4.9/464

5.2/494

5.5/524

6.0/573

6.3/606

 

1-ON

 

 

 

 

 

 

 

 

 

 

 

 

3-ON

 

 

 

o

 

 

 

 

 

 

 

 

2-ON

2041

 

 

60

4.8/457

5.3/507

5.8/557

6.2/599

6.7/647

7.2/704

7.8/757

 

 

 

 

 

1-OFF

 

 

 

 

 

 

 

 

 

 

 

 

3-ON

2223

 

 

o

 

 

 

 

 

 

 

 

2-ON

 

 

55

6.4/624

7.0/680

7.6/734

8.2/808

8.7/866

8.4/923

9.8/975

 

1-ON

 

 

 

 

 

 

 

 

 

 

 

= Recommended Heating Speed Setting

Figure 18-1A: ECM blower motor speed chart

29

Image 32
Contents OH6FA072DV4N OH6FX072DV4R OH6FA072DV4BOH6FA072DV4R Contents = Highboy D = Downflow = FrontSafety Section Page Codes and Clearances Combustible materialNon-combustible material II. General Instructions Read Before Start of Installation Type Model NO.1 From Sides Front Unit FurnaceHighboy OH6FA072D OH8FA119D TOP Sides of Plenum From Rear FLUE/VENTPrevention of Chimney Condensing ChimneyProper Chimney Size Proper Vent Connector PIPE/CHIMNEY Connection Proper Chimney HeightTight CLEAN-OUT Doors and Connections Tight JointsNo Interconnected Chimney Flues Flue Pipe CLEARANCES, Sizing and TypeReduction of Clearances with Specified Forms of Protection Venting Rotation of Front Flue ElbowDraft Regulators Duct WORK/AIR ConditioningAirflow Requirements and Sizing of Duct Work Page Supply air duct sizing Example Air Filter Mounted External to Furnace ExamplesA typical filter rack and dimensions for the OH6 furnace OH6 OH8 Limit Position and LocationMaximum Filter Type Air Velocity Model Number Ft/min Burner Installation Do not remove this retainer when installing burnerBurner Specifications and Applications Do not Change Position of the ChamberBeckett Riello BTU/HRMounting the 2-STAGE Riello Burner BTU/HR Heating CapacityOIL Tank and Piping OIL Filter Electrical WiriingElectronic Air Cleaner EAC and Humidifier Installation Thermostat Anticipator Setting Fan Control ModulePreferred method of adjustment Heat Anticipator Adjustment ScaleBlower Motor Speed Selection Heating Speed Set-ups OH6FA072DV41A ECM blower motor speed chart OH8FA119DV5Heating Speed Set-ups 2 Stage OH6FX072DV4Cooling blower motor speed chart 3A Cooling blower motor speed chart Cooling Speed Set-upsOH6FA072D48 HighOH8FA119D60 12.5/1270 11.7/1200 11.2/1150 10.7/1110 10.2/1060 1020 969Terminal Definitions & Field Wiring Blower Controller Information for PSC MotorInputs OutputsOperating Modes On and OFF Blower Delay Time Switch Settings PSC Trouble Shooting Diagnostic FeaturesOperating Instructions Startup ProceduresSTOP! Read the safety information above Adjustment of Burner Combustion To Turn Off Oil to ApplianceCombustion Head Setting for 2-STAGE Riello Burner Preliminary Adjustment of Burner Air Band and Air ShutterTurn to the Left Sign AIR Damper AdjustmentTurn to the Right Sign + 1st Stage Adjustment 2nd Stage AdjustmentAdjustment Of Heat Input Rate Page Checkout Procedure III. Users Information Section Inspection AreasFilter Cleaning and Location Starting the BurnerIV. Installers Instructions to User Dealer Maintenance Safety During Servicing and InspectionGeneral Inspection Heat ExchangerHeat Exchanger Cleaning Instructions OH6 8FT OH8 8FT Filter maintenance procedure Electrical SystemSUPPLY/RETURN AIR Blower SUPPLY/RETURN AIR FilterOn Shutdown Filter replacementExtended Appliance Shutdown VI. HOMEOWNER/USER Information and Routine Maintenance On StartupPage Location of oil primary control reset button Beckett Burner Riello BurnerDiagnostics Diagnostic FeaturesCAD Cell Checkout Procedure Number of flashes Cad Cell Resistance in ohms Model R7184BPage VIII. Sequence of Operations Flow Chart Page IX. Trouble Shooting Flow Chart Page Page Page Page Customer Appendix a Replacement Parts Replacement Parts for OH8FA119D Appendix B Wiring Diagrams OH6FA072DV4 ECM Wiring Diagram OH6FX072DV4 ECM 2-Stage Wiring Diagram OH8FA1119D60 PSC Wiring Diagram OH8FA1119DV5 ECM Wiring Diagram
Related manuals
Manual 78 pages 920 b

OH8FA119D60B, OH8FA119DV5B, OH6FX072DV4R, OH6FA072DV4N, OH6FA072D48N specifications

Thermo Products has established a reputation for delivering high-quality heating solutions tailored for various applications. Among their standout offerings are the OH8FA119DV5R, OH8FA119D60R, OH6FA072D48B, OH6FA072D48N, and OH6FA072DV4N models. These units are engineered with precision and incorporate advanced technologies to deliver reliable performance in residential and commercial settings.

One of the main features of these models is their energy efficiency. They utilize modern heat exchanger designs, which allow for maximum heat transfer while minimizing energy consumption. This not only helps in reducing utility bills but also supports sustainable practices by lowering the carbon footprint. Many systems are also equipped with variable-speed motors, providing precise airflow control, which enhances comfort while operating quietly.

In addition to their energy efficiency, these units incorporate smart technology that allows for seamless integration into home automation systems. This feature enables users to monitor and control their heating systems remotely through mobile apps, making it convenient to adjust settings for optimal comfort. The smart thermostats associated with these models often feature learning capabilities, which adapt to users' habits to optimize heating schedules further.

Durability is another standout characteristic of the OH8FA and OH6FA series. Built with robust materials, these heaters are designed to withstand the rigors of daily use. Many units come with extended warranties, reflecting the manufacturer's confidence in their longevity. Furthermore, corrosion-resistant components ensure that the units maintain their performance over time, even in challenging environments.

Safety is also a key consideration in these products. Equipped with multiple safety features, including overheat protection and flame sensors, users can rest assured their heating systems operate without risk. Additionally, these models often include advanced diagnostics, making troubleshooting easier and enhancing user experience.

In summary, Thermo Products' OH8FA119DV5R, OH8FA119D60R, OH6FA072D48B, OH6FA072D48N, and OH6FA072DV4N represent a blend of efficiency, technology, durability, and safety in heating solutions. Whether for a cozy home or a large commercial space, these models offer versatile options to meet diverse heating needs while prioritizing energy conservation and user convenience. As the demand for efficient heating continues to rise, Thermo Products remains a leader in providing innovative solutions that cater to modern heating requirements.