IV. INSTALLER'S INSTRUCTIONS TO USER:

After completing the installation, the installer shall inform and/or demonstrate to the homeowner the following items:

1.The location of these instructions. The instructions must be kept along with instructions for any accessories in the plastic pouch with the appliance.

2.The location and use of the manual oil shutoff valve and appliance electrical disconnecting device. The end user must be instructed to always shut off the electric power to the appliance, before shutting off the oil supply.

3.The sequence of operation of the appliance.

4.The correct operation and maintenance of the appliance, as outlined in the Homeowner/User Information and Routine Maintenance section of this manual.

5.That failure to maintain and operate this appliance in accordance with these instructions could result in hazardous conditions, property damage, and bodily injury. It may also void the limited warranty on the appliance.

6.Review with and encourage the user to read the label reproductions and all warnings and instructions outlined on the front cover and in Sections I, II, and III, of this manual.

7.Recommend the user have a qualified heating contractor inspect the entire appliance at least once a year. Inform the user of the frequency of inspection required for each item in the Dealer Maintenance section of this manual.

8.Inform the user to maintain adequate clearances around air openings into the appliance housing and not to block or restrict the entrance of air into the condenser coil or the burner compartment air openings.

50

Image 53
Contents OH6FA072DV4N OH6FX072DV4R OH6FA072DV4BOH6FA072DV4R Contents = Front = Highboy D = DownflowSafety Section Page Combustible material Codes and ClearancesNon-combustible material Type Model NO.1 From Sides Front Unit Furnace II. General Instructions Read Before Start of InstallationHighboy OH6FA072D OH8FA119D TOP Sides of Plenum From Rear FLUE/VENTPrevention of Chimney Condensing ChimneyProper Chimney Size Proper Chimney Height Proper Vent Connector PIPE/CHIMNEY ConnectionTight Joints Tight CLEAN-OUT Doors and ConnectionsNo Interconnected Chimney Flues Flue Pipe CLEARANCES, Sizing and TypeReduction of Clearances with Specified Forms of Protection Rotation of Front Flue Elbow VentingDuct WORK/AIR Conditioning Draft RegulatorsAirflow Requirements and Sizing of Duct Work Page Supply air duct sizing Example Examples Air Filter Mounted External to FurnaceA typical filter rack and dimensions for the OH6 furnace OH6 OH8 Limit Position and LocationMaximum Filter Type Air Velocity Model Number Ft/min Do not remove this retainer when installing burner Burner InstallationDo not Change Position of the Chamber Burner Specifications and ApplicationsBTU/HR Beckett RielloBTU/HR Heating Capacity Mounting the 2-STAGE Riello BurnerOIL Tank and Piping Electrical Wiriing OIL FilterElectronic Air Cleaner EAC and Humidifier Installation Fan Control Module Thermostat Anticipator SettingHeat Anticipator Adjustment Scale Preferred method of adjustmentBlower Motor Speed Selection OH6FA072DV4 Heating Speed Set-upsOH8FA119DV5 1A ECM blower motor speed chartOH6FX072DV4 Heating Speed Set-ups 2 StageCooling blower motor speed chart Cooling Speed Set-ups 3A Cooling blower motor speed chartHigh OH6FA072D4812.5/1270 11.7/1200 11.2/1150 10.7/1110 10.2/1060 1020 969 OH8FA119D60Blower Controller Information for PSC Motor Terminal Definitions & Field WiringOutputs InputsOperating Modes On and OFF Blower Delay Time Switch Settings Diagnostic Features PSC Trouble ShootingOperating Instructions Startup ProceduresSTOP! Read the safety information above To Turn Off Oil to Appliance Adjustment of Burner CombustionPreliminary Adjustment of Burner Air Band and Air Shutter Combustion Head Setting for 2-STAGE Riello BurnerTurn to the Left Sign AIR Damper AdjustmentTurn to the Right Sign + 2nd Stage Adjustment 1st Stage AdjustmentAdjustment Of Heat Input Rate Page Checkout Procedure Inspection Areas III. Users Information SectionStarting the Burner Filter Cleaning and LocationIV. Installers Instructions to User Safety During Servicing and Inspection Dealer MaintenanceGeneral Inspection Heat ExchangerHeat Exchanger Cleaning Instructions OH6 8FT OH8 8FT Electrical System Filter maintenance procedureSUPPLY/RETURN AIR Blower SUPPLY/RETURN AIR FilterOn Shutdown Filter replacementExtended Appliance Shutdown On Startup VI. HOMEOWNER/USER Information and Routine MaintenancePage Beckett Burner Riello Burner Location of oil primary control reset buttonDiagnostic Features DiagnosticsCAD Cell Checkout Procedure Number of flashes Cad Cell Resistance in ohms Model R7184BPage VIII. Sequence of Operations Flow Chart Page IX. Trouble Shooting Flow Chart Page Page Page Page Customer Appendix a Replacement Parts Replacement Parts for OH8FA119D Appendix B Wiring Diagrams OH6FA072DV4 ECM Wiring Diagram OH6FX072DV4 ECM 2-Stage Wiring Diagram OH8FA1119D60 PSC Wiring Diagram OH8FA1119DV5 ECM Wiring Diagram
Related manuals
Manual 78 pages 920 b

OH8FA119D60B, OH8FA119DV5B, OH6FX072DV4R, OH6FA072DV4N, OH6FA072D48N specifications

Thermo Products has established a reputation for delivering high-quality heating solutions tailored for various applications. Among their standout offerings are the OH8FA119DV5R, OH8FA119D60R, OH6FA072D48B, OH6FA072D48N, and OH6FA072DV4N models. These units are engineered with precision and incorporate advanced technologies to deliver reliable performance in residential and commercial settings.

One of the main features of these models is their energy efficiency. They utilize modern heat exchanger designs, which allow for maximum heat transfer while minimizing energy consumption. This not only helps in reducing utility bills but also supports sustainable practices by lowering the carbon footprint. Many systems are also equipped with variable-speed motors, providing precise airflow control, which enhances comfort while operating quietly.

In addition to their energy efficiency, these units incorporate smart technology that allows for seamless integration into home automation systems. This feature enables users to monitor and control their heating systems remotely through mobile apps, making it convenient to adjust settings for optimal comfort. The smart thermostats associated with these models often feature learning capabilities, which adapt to users' habits to optimize heating schedules further.

Durability is another standout characteristic of the OH8FA and OH6FA series. Built with robust materials, these heaters are designed to withstand the rigors of daily use. Many units come with extended warranties, reflecting the manufacturer's confidence in their longevity. Furthermore, corrosion-resistant components ensure that the units maintain their performance over time, even in challenging environments.

Safety is also a key consideration in these products. Equipped with multiple safety features, including overheat protection and flame sensors, users can rest assured their heating systems operate without risk. Additionally, these models often include advanced diagnostics, making troubleshooting easier and enhancing user experience.

In summary, Thermo Products' OH8FA119DV5R, OH8FA119D60R, OH6FA072D48B, OH6FA072D48N, and OH6FA072DV4N represent a blend of efficiency, technology, durability, and safety in heating solutions. Whether for a cozy home or a large commercial space, these models offer versatile options to meet diverse heating needs while prioritizing energy conservation and user convenience. As the demand for efficient heating continues to rise, Thermo Products remains a leader in providing innovative solutions that cater to modern heating requirements.