SPX Cooling Technologies 160 manual Steel Basin Support, Overall Width

Page 8

/ Steel Basin Support /

76 θ

A

BASIN

756Oθ

 

E BAYS @ 4α-0θ= L

OUT OF

C

 

BASIN

L COL.

FACE “B”

 

 

AIR INLET FACE

COL.CL

 

 

 

 

 

 

EACH ADDITIONAL CELL= L

 

756Oθ

C

C

OUT OF

L COL.

COL.L

BASIN

 

 

 

 

 

 

 

 

 

 

OF

B

OVERALL WIDTH

B

W

 

 

A

 

76 θ

D

 

C

FACE

C

“C” CASED

D

FACE

 

LCOL.

 

C

SUMP

OVERFLOW

FACE “D”

AIR INLET FACE

ADDITIONAL SUMP

CASED FACE

“A”

WHEN REQUIRED

FACE

 

ADDITIONAL OVERFLOW

WHEN REQUIRED

Note: Two beams shown phantom are required on Models 1651 and 1661 only. All

dimensions are to centers of tower columns—notcenters of anchor bolts or beams.

4OWER

 

 

 

 

$IMENSIONS

 

 

 

/PERATING 7EIGHT

 

 

 

 

 

 

 

 

LB

-ODEL

 

 

 

 

 

 

 

 

 

7

!

 

"

#

$

%

,

3INGLE #ELL

%ACH #ELL !DD

 

 



αθ

α 6

θ

αθ

 

 



αθ

 

 



αθ

α 6

θ

αθ

 

 



αθ

 

 



αθ

α 6

θ

αθ

 

 



αθ

 

 



αθ

α 6

θ

αθ

 

 



αθ

 

 



αθ

α 6 θ

 

α (6 θ

α 56 θ



αθ

 

 



αθ

α 6

θ

 

α 56Oθ

α 56Oθ



αθ

 

 

 

 

 

 

 

 

 

 

 

 

 

1.Use this bulletin for preliminary layouts only. All dimensions show column locations, not anchor bolt locations. Obtain current drawings from your Marley sales representative before designing supports.

2.Other contractors or purchaser must design and erect support- ing steel.

3.If steel beams are used, they must include ⁷⁄dia. holes to accept anchor bolts provided by Marley. If concrete beams or pilasters are used, ³⁄dia. anchor bolts imbedded in the con- crete must be provided by others.

4.Maintain no less than 2-0of clear space at cased faces for construction purposes. Air inlet faces must have unobstructed air supply. Consult your Marley sales representative if nearby obstructions may interfere.

5.Operating weight is wet weight of tower and wood basin, including 6of water in the cold water basin. This is the recom- mended operating water level for all models.

6.For collection basin accessories information request Marley drawing 90-3231 from your Marley sales representative.

8

Image 8
Contents Marley Class 160 CoolingTower  Marley Difference Class 160 Tower AdvantageMechanical Equipment Construction and ComponentsFill/Louvers/Drift Eliminators Water Distribution System Structure and MaterialsCold Water Basin Access and SafetyCasing System Cleanliness Operating and Environmental ConsiderationsTower Schematic IFTSteel Basin Support Overall WidthConcrete Basin Odel 3INGLE #ELLInlet Piping Plan 4OWER $IMENSIONS Odel PER #ELLFire Safety Options Available OptionsCell Partition Options Cold Water Collection BasinsAccessory Description and Remarks

160 specifications

SPX Cooling Technologies 160 is a prominent cooling tower option designed for a range of industrial and commercial applications. This advanced system reflects a commitment to efficiency, performance, and adaptability, making it a leading choice for organizations looking to optimize their cooling processes.

One of the standout features of the SPX Cooling Technologies 160 is its modular design. This allows for flexibility in installation and scalability based on specific cooling requirements. Whether you need a single unit or multiple towers, the modularity ensures that the system can be configured to meet the unique demands of various projects.

The cooling tower employs advanced materials that enhance durability and resistance to corrosion, extending the lifespan of the system. This is crucial for industrial environments where exposure to harsh conditions is common. The design focuses on energy efficiency as well, incorporating fan and motor technology that reduces power consumption while maximizing airflow and cooling performance.

Another significant characteristic of the SPX 160 is its advanced thermal performance. With a well-designed heat transfer surface, the cooling tower operates efficiently, ensuring optimal heat exchange between the water and the air. This process effectively reduces water temperatures, leading to significant energy savings and improved operational efficiency.

The unit is equipped with state-of-the-art controls that enhance its functionality. These smart control systems allow for precise regulation of cooling operations, optimizing performance based on real-time needs. This not only boosts efficiency but also supports maintenance schedules, aiding in the longevity of the equipment.

Furthermore, the SPX Cooling Technologies 160 is designed with environmental considerations in mind. It features low-noise operation, which is essential for installations in noise-sensitive areas. Additionally, the cooling tower can be customized with options that minimize water usage, aligning with sustainability goals many organizations prioritize today.

Overall, the SPX Cooling Technologies 160 stands out in the market for its combination of adaptability, efficiency, and innovation. Its design and features make it a compelling solution for businesses in need of reliable cooling solutions, ultimately contributing to improved operational performance and sustainability. Whether for industrial plants, commercial buildings, or unique applications, the SPX 160 is a credible option in the cooling technology landscape.