5.6 High Altitude

These heaters are approved (without modifications) for installations up to 2000' (610

m)in US and Canada. Heaters installed above 2000' (610 m) must be de-rated. For installations above 2000' (610 m) in US, consult factory for information on burner de-rating. For installations from 2000' (610 m) to 4500' (1370m) in Canada, high altitude conversion kits are available. Heaters installed over 4500' (1370 m) in Canada are not approved and must be approved by the local or provincial authority.

8 of 47

Image 16
Contents Combat Page Combat Page Roberts-Gordon LLC Page Table of Figures Page Heater Safety Manpower RequirementsSafety Labels and Their Placement California PropositionUhdxs 75 Label Placement Combat Installer Responsibility Wall TagCorrosive Chemicals National Standards and Applicable CodesCritical Considerations Clearances to Combustibles National Standards and Applicable Codes High Altitude Duct Heater Installation 6.1 General Temperature Rise and Pressure Drop RangesAir Flow and Temperature Rise Ranges Minimum Inlet Duct LengthWall Mounting Suspension MethodsShelf-Mounting Methods Vent Installation VentingUnited States Requirements Canadian RequirementsStandard Vented Heaters Models Uhdx 75 Horizontal VentingVertical Venting Length RequirementsVent Material Maximum Vent LengthsReplacing an Existing Heater in a Venting System Model Standard Vented Heater Common Vertical Vent Termination Concentric Vent Box UHVK1 Unvented Installation AIR SupplyBuilding Ventilation Outside Combustion Air SupplyFire Hazard Connect gas supply according to Figure GAS PipingConnections Product Damage Hazard When attaching flexible gass connectorHold gas nipple securely with pip wrench Wiring Uhdxs Series Internal Wiring Diagram L2 L1Uhdxs Series Ladder Wiring Diagram Flue Blower Transformer GAS Valve Flame Sensor ElectrodeElectrical Connection to the Heater Operation and Maintenance Pre-Start-Up ChecksElectrical Checks Begin Start-Up Before Operating the HeaterAutomatic Burner Control Sequence END ViewPressure Switch Check Gas RateTurning Off the Heater External ControlsUser Instructions Heater OperationSimple Troubleshooting Simple Troubleshooting Burner FaultsLighting Instructions 12.3.1 To Turn On Heater To Turn Heater OffServicing Annual Fall Start-up Vicinity of the HeaterVehicles and Other ObjectsWhen installed Ductwork Combustion Air IntakePipe Heat ExchangerTroubleshooting General StartTroubleshooting For Automatic Ignition Burner Systems Conduct start-up procedure as shown on Page 26, SectionTroubleshooting for Flame Supervision System Troubleshooting for Gas Valves Troubleshooting for Flue BlowerReplacement Parts Burner ComponentsBurner Compartment Burner InjectorsIgnition Electrode and Flame Probe Flue Blower Vertical Installation Limit Switches Removal and Replacement Ignition ControlSpecifications 16.1 Dimension Data TOP ViewGeneral Technical Data Table Technical Data TablePage Warranty is Void if ROBERTS-GORDON LLC will not PAY forRoberts-Gordon LLC Limitations on Authority RepresentativesPage Owner Warranty Registration Card Mail or Fax toPage
Related manuals
Manual 62 pages 55.65 Kb

125, 100, 75 specifications

Roberts Gordon is a recognized leader in the manufacturing of innovative heating solutions, with a diverse product line including the 100, 125, 75, 45, and 60 series of radiant tube heaters. Each model is designed to meet specific heating needs while emphasizing efficiency, durability, and performance.

The Robert Gordon 100 series is known for its high efficiency and ability to provide consistent warmth in large industrial spaces. It features advanced infrared technology, which heats objects and surfaces directly, resulting in quicker temperature increases and enhanced comfort. This model is equipped with modulating burners that allow for optimal gas usage and can be easily integrated into existing systems.

The 125 series builds upon the efficiency of the 100 model while offering increased heating capacity. Its robust design ensures it can handle the demands of larger applications, such as warehouses and manufacturing facilities. With enhanced control options, users can tailor the heating output to match specific operational requirements, reducing energy consumption.

The 75 series offers a compact solution for smaller commercial spaces, providing a reliable heating source without taking up excessive floor space. Its lightweight design facilitates easy installation, while the modular approach allows for scalability to meet changing heating demands. This series emphasizes sustainability, utilizing advanced combustion technologies that minimize emissions.

For smaller applications, the 45 series stands out with its efficient heating capabilities in confined spaces. This series features simple, yet effective controls, enabling straightforward operation. The robust construction ensures durability, making it well-suited for different commercial environments, including retail settings or small workshops.

Finally, the 60 series combines the best features of the range with energy conservation as a primary focus. Its innovative design incorporates smart technology to monitor energy usage and optimize performance. The heaters are equipped with the latest in safety features, providing peace of mind for users.

Overall, Roberts Gordon’s radiant tube heaters showcase a commitment to high-quality heating solutions that cater to a variety of industrial and commercial applications. With energy efficiency, superior durability, and advanced heating technologies as core characteristics, Roberts Gordon remains a trusted choice for businesses looking to enhance their heating performance.