Roberts Gorden 75, 100 Heater Safety, Manpower Requirements, Safety Labels and Their Placement

Page 9

SECTION 1: HEATER SAFETY

SECTION 1: HEATER SAFETY

Your Safety is Important to Us! This symbol is used throughout the manual to notify you of possible fire, electrical or burn hazards. Please pay special

attention when reading and following the warnings in these sections.

Installation, service and, at a

minimum, annual inspection of heater must be done by a contractor qualified in the installation and service of gas-fired heating equipment.

Read this manual carefully before installation, operation or service of this equipment. Heaters are not approved for residential installations. These instructions, the layout drawing, local codes and ordinances and applicable standards that apply to gas piping, electrical wiring, venting, etc. must be thoroughly understood before proceeding with the installation.

Protective gear is to be worn during installation, operation and service. Thin sheet metal parts, including the various venting components, have sharp edges. To prevent injury, the use of work gloves is recommended.

Before installation, check that the local distribution conditions, nature of gas and pressure and adjustment of the appliance are compatible.

This heater must be applied and operated under the general concepts of reasonable use and installed using the best building practices.

This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.

For additional copies of the Installation, Operation and Service Manual, please contact Roberts- Gordon LLC.

1.1 Manpower Requirements

To prevent personal injury and damage to the heater, two persons will be required for installation.

1.2 Safety Labels and Their Placement

Product safety signs or labels should be replaced by the product user when they are no longer legible. Please contact Roberts-Gordon LLC or your ROBERTS GORDON® independent distributor to obtain replacement signs or labels. See Page 2, Figure 1 through Page 3, Figure 2.

1.3 California Proposition 65

In accordance with California Proposition 65

requirements, a warning label must be placed in a highly visible location on the outside of the equipment (i.e. near equipment's serial plate). See label placement drawing on Page 2, Figure 1 through Page 3, Figure 2 for label location. Avoid placing label on areas with extreme heat, cold, corrosive chemicals or other elements. To order additional labels, please contact Roberts-Gordon LLC or your ROBERTS GORDON® independent distributor.

1 of 47

Image 9
Contents Combat Page Combat Page Roberts-Gordon LLC Page Table of Figures Page Manpower Requirements Heater SafetySafety Labels and Their Placement California PropositionUhdxs 75 Label Placement Combat Wall Tag Installer ResponsibilityCorrosive Chemicals National Standards and Applicable CodesCritical Considerations Clearances to Combustibles National Standards and Applicable Codes High Altitude Temperature Rise and Pressure Drop Ranges Duct Heater Installation 6.1 GeneralAir Flow and Temperature Rise Ranges Minimum Inlet Duct LengthSuspension Methods Wall MountingShelf-Mounting Methods Venting Vent InstallationUnited States Requirements Canadian RequirementsHorizontal Venting Standard Vented Heaters Models Uhdx 75Vertical Venting Length RequirementsMaximum Vent Lengths Vent MaterialReplacing an Existing Heater in a Venting System Model Standard Vented Heater Common Vertical Vent Termination Concentric Vent Box UHVK1 AIR Supply Unvented InstallationBuilding Ventilation Outside Combustion Air SupplyGAS Piping Fire Hazard Connect gas supply according to FigureConnections When attaching flexible gass connector Product Damage HazardHold gas nipple securely with pip wrench Wiring L2 L1 Uhdxs Series Internal Wiring DiagramFlue Blower Transformer GAS Valve Flame Sensor Electrode Uhdxs Series Ladder Wiring DiagramElectrical Connection to the Heater Pre-Start-Up Checks Operation and MaintenanceElectrical Checks Begin Start-Up Before Operating the HeaterEND View Automatic Burner Control SequenceCheck Gas Rate Pressure SwitchTurning Off the Heater External ControlsHeater Operation User InstructionsSimple Troubleshooting Burner Faults Simple TroubleshootingLighting Instructions 12.3.1 To Turn On Heater To Turn Heater OffServicing Vicinity of the Heater Annual Fall Start-upVehicles and Other ObjectsCombustion Air Intake When installed DuctworkPipe Heat ExchangerTroubleshooting Start GeneralConduct start-up procedure as shown on Page 26, Section Troubleshooting For Automatic Ignition Burner SystemsTroubleshooting for Flame Supervision System Troubleshooting for Flue Blower Troubleshooting for Gas ValvesBurner Components Replacement PartsBurner Injectors Burner CompartmentIgnition Electrode and Flame Probe Flue Blower Vertical Installation Ignition Control Limit Switches Removal and ReplacementTOP View Specifications 16.1 Dimension DataTechnical Data Table General Technical Data TablePage ROBERTS-GORDON LLC will not PAY for Warranty is Void ifRoberts-Gordon LLC Limitations on Authority RepresentativesPage Mail or Fax to Owner Warranty Registration CardPage
Related manuals
Manual 62 pages 55.65 Kb

125, 100, 75 specifications

Roberts Gordon is a recognized leader in the manufacturing of innovative heating solutions, with a diverse product line including the 100, 125, 75, 45, and 60 series of radiant tube heaters. Each model is designed to meet specific heating needs while emphasizing efficiency, durability, and performance.

The Robert Gordon 100 series is known for its high efficiency and ability to provide consistent warmth in large industrial spaces. It features advanced infrared technology, which heats objects and surfaces directly, resulting in quicker temperature increases and enhanced comfort. This model is equipped with modulating burners that allow for optimal gas usage and can be easily integrated into existing systems.

The 125 series builds upon the efficiency of the 100 model while offering increased heating capacity. Its robust design ensures it can handle the demands of larger applications, such as warehouses and manufacturing facilities. With enhanced control options, users can tailor the heating output to match specific operational requirements, reducing energy consumption.

The 75 series offers a compact solution for smaller commercial spaces, providing a reliable heating source without taking up excessive floor space. Its lightweight design facilitates easy installation, while the modular approach allows for scalability to meet changing heating demands. This series emphasizes sustainability, utilizing advanced combustion technologies that minimize emissions.

For smaller applications, the 45 series stands out with its efficient heating capabilities in confined spaces. This series features simple, yet effective controls, enabling straightforward operation. The robust construction ensures durability, making it well-suited for different commercial environments, including retail settings or small workshops.

Finally, the 60 series combines the best features of the range with energy conservation as a primary focus. Its innovative design incorporates smart technology to monitor energy usage and optimize performance. The heaters are equipped with the latest in safety features, providing peace of mind for users.

Overall, Roberts Gordon’s radiant tube heaters showcase a commitment to high-quality heating solutions that cater to a variety of industrial and commercial applications. With energy efficiency, superior durability, and advanced heating technologies as core characteristics, Roberts Gordon remains a trusted choice for businesses looking to enhance their heating performance.