Roberts Gorden AT-136, AT-272, AT-254, AT-260, AT-242, AT-148, AT-154, AT-236, AT-248 manual 10,000

Page 7

Tables B: Air Turnover Heating Unit with Filtration Performance Information

(Additional configurations are available upon request.)

AT-136

CFM

Motor (HP)

Output

Output

Temp. Rise

Base Unit

(MBH)

(MBH)

Range (°F)

Weight

 

 

Minimum

Maximum

(lbs.)

4,500

1 (1 motor)

240

450

49 to 93

2,425

9,000

3 (1 motor)

240

450

25 to 46

2,505

12,000

5 (1 motor)

240

450

19 to 35

2,520

AT-148

 

 

 

Output

Output

Temp. Rise

Base Unit

 

CFM

Motor (HP)

(MBH)

(MBH)

Weight

 

Range (°F)

 

 

 

Minimum

Maximum

(lbs.)

 

 

 

 

 

10,000

3 (1 motor)

240

450

22 to 42

3,455

 

16,000

5 (1 motor)

240

750

14 to 43

3,470

AT-154

CFM

Motor (HP)

Output

Output

Temp. Rise

Base Unit

(MBH)

(MBH)

Range (°F)

Weight

 

 

Minimum

Maximum

(lbs.)

14,000

3 (1 motor)

240

450

16 to 30

4,080

22,000

5 (1 motor)

240

750

10 to 32

4,140

30,000

10 (1 motor)

520

1,000

16 to 31

4,210

30,000

10 (1 motor)

560

1,250

17 to 39

4,420

AT-236

CFM

Motor (HP)

Output

Output

Temp. Rise

Base Unit

(MBH)

(MBH)

Range (°F)

Weight

 

 

Minimum

Maximum

(lbs.)

9,000

1 (2 motors)

240

450

25 to 46

4,145

18,000

3 (2 motors)

240

750

12 to 39

4,240

24,000

5 (2 motors)

520

1,000

20 to 39

4,270

AT-242

CFM

Motor (HP)

Output

Output

Temp. Rise

Base Unit

(MBH)

(MBH)

Range (°F)

Weight

 

 

Minimum

Maximum

(lbs.)

21,000

3 (2 motors)

240

750

11 to 33

5,240

31,000

5 (2 motors)

520

1,000

16 to 30

5,270

31,000

5 (2 motors)

560

1,250

17 to 37

5,445

AT-248

CFM

Motor (HP)

Output

Output

Temp. Rise

Base Unit

(MBH)

(MBH)

Range (°F)

Weight

 

 

Minimum

Maximum

(lbs.)

22,000

3 (2 motors)

240

750

10 to 32

6,190

35,000

5 (2 motors)

520

1,000

14 to 26

6,345

45,000

7.5 (2 motors)

560

1,250

12 to 26

6,575

45,000

7.5 (2 motors)

560

1,500

12 to 31

6,730

AT-254

CFM

Motor (HP)

Output

Output

Temp. Rise

Base Unit

(MBH)

(MBH)

Range (°F)

Weight

 

 

Minimum Maximum

(lbs.)

40,000

5 (2 motors)

560

1,750

13 to 41

7,870

60,000

10 (2 motors)

600

2,250

9 to 35

8,310

65,000

10 (2 motors)

600

2,500

9 to 36

8,560

AT-260

CFM

Motor (HP)

Output

Output

Temp. Rise

Base Unit

(MBH)

(MBH)

Range (°F)

Weight

 

 

Minimum

Maximum

(lbs.)

54,000

5 (2 motors)

600

3,000

10 to 51

11,070

61,000

7.5 (2 motors)

720

4,000

11 to 61

11,335

74,000

10 (2 motors)

720

4,000

9 to 50

11,385

AT-272

CFM

Motor (HP)

Output

Output

Temp. Rise

Base Unit

(MBH)

(MBH)

Range (°F)

Weight

 

 

Minimum Maximum

(lbs.)

62,000

7.5 (2 mo-

600

3,000

9 to 45

12,160

tors)

 

 

 

 

 

88,000

10 (2 motors)

720

4,500

8 to 47

12,385

100,000

15 (2 motors)

720

4,500

7 to 42

12,515

Tables C: Air Turnover Cooling Unit with Filtration Performance Information

(For cooling applications, consult factory. Base Unit Weights do not account for inclusion of cooling coils or exclusion of heat exchanger. Additional configurations are available upon request.)

AT-136

CFM

Motor (HP)

Base Unit Weight (lbs.)

 

 

 

 

 

4,500

1 (1 motor)

2,425

9,000

3 (1 motor)

2,505

12,000

5 (1 motor)

2,520

 

 

 

 

 

AT-148

 

 

 

 

CFM

Motor (HP)

Base Unit Weight (lbs.)

 

 

 

 

 

10,000

3 (1 motor)

 

3,455

16,000

5 (1 motor)

 

3,470

 

 

 

 

 

AT-154

 

 

 

 

CFM

Motor (HP)

Base Unit Weight (lbs.)

 

 

 

 

 

14,000

5 (1 motor)

 

 

4,080

22,000

5 (1 motor)

 

 

4,140

30,000

10 (1 motor)

 

 

4,210

30,000

10 (1 motor)

 

 

4,420

 

 

 

 

 

AT-236

 

 

 

 

CFM

Motor (HP)

Base Unit Weight (lbs.)

 

 

 

 

9,000

2 (1 motors)

 

4,145

18,000

3 (2 motors)

 

4,240

24,000

5 (2 motors)

 

4,270

 

 

 

 

 

AT-242

 

 

 

 

CFM

Motor (HP)

Base Unit Weight (lbs.)

 

 

 

21,000

3 (2 motors)

5,240

31,000

5 (3 motors)

5,270

31,000

5 (3 motors)

5,445

AT-248

CFM

Motor (HP)

Base Unit Weight (lbs.)

 

 

 

22,000

3 (2 motors)

6,190

35,000

5 (2 motors)

6,345

45,000

7.5 (2 motors)

6,575

45,000

7.5 (2 motors)

6,730

AT-254

CFM

Motor (HP)

Base Unit Weight (lbs.)

 

 

 

40,000

5 (2 motors)

7,870

60,000

10 (2 motors)

8,310

65,000

10 (2 motors)

8,560

AT-260

CFM

Motor (HP)

Base Unit Weight (lbs.)

 

 

 

54,000

5 (2 motors)

11,070

61,000

7.5 (2 motors)

11,335

74,000

10 (2 motors)

11,385

AT-272

CFM

Motor (HP)

Base Unit Weight (lbs.)

 

 

 

62,000

7.5 (2 motors)

12,160

88,000

10 (2 motors)

12,385

100,000

15 (2 motors)

12,515

7

Image 7
Contents Combat AT-Series Indirect-Fired Air Turnover Units Dimension Selection GuideAT-Series Heating Unit DimensionsAT-Series Heating Unit with Filtration END View AT-Series Cooling Unit with FiltrationFront View END View AT-Series Heating and Cooling Unit with FiltrationAT-Series Selection Guide Estimated Shipping Weights Burners ALL ModelsTables a Air Turnover Heating Unit Performance Information 10,000 European Office

AT-248, AT-136, AT-236, AT-154, AT-148 specifications

Roberts Gorden, a prominent manufacturer in the heating and ventilation industry, offers a range of advanced infrared heating solutions designed for commercial and industrial applications. Among its diverse portfolio, the AT series, specifically the AT-148, AT-242, AT-136, AT-254, and AT-260, stands out for its efficiency and innovative features.

The Roberts Gorden AT series is renowned for its advanced radiant heating technology. These heaters operate by directly warming objects and people in the space, rather than just the air. This results in lower energy consumption and enhanced comfort levels, making them ideal for large open areas such as warehouses, manufacturing facilities, and gymnasiums.

One of the key features of these models is their high thermal efficiency. The AT series is designed to offer significant energy savings compared to conventional heating methods. With efficient burner systems and reflective surfaces, these heaters can operate at high efficiency, ensuring that a greater percentage of the fuel used is converted into useful heat.

The AT-148, for instance, is known for its compact design, making it suitable for spaces with limited installation options. Despite its small size, it delivers powerful heating performance. The AT-242 and AT-254 models offer larger heating capacities, making them well-suited for expansive areas that require uniform heat distribution. The AT-260 model stands out for its ability to deliver high output even in challenging environments.

Each model in the AT series is equipped with advanced control systems, allowing for precise temperature regulation and energy management. This feature ensures that users can adapt heating output based on occupancy and specific needs, further enhancing energy efficiency.

Durability is another hallmark of the Roberts Gorden AT series. Constructed with high-quality materials, these heaters are built to withstand harsh industrial environments. Their robust design ensures a long lifespan with minimal maintenance requirements.

In summary, the Roberts Gorden AT-148, AT-242, AT-136, AT-254, and AT-260 models exemplify innovation in radiant heating technology. Featuring high efficiency, advanced control systems, and durable construction, they are engineered to provide optimal heating solutions for a variety of commercial and industrial settings. Whether for large warehouses or specialized industrial applications, the AT series offers a reliable and energy-efficient heating option.