Roberts Gorden AT-242, AT-272, AT-254, AT-260, AT-148, AT-154 AT-Series Heating Unit with Filtration

Page 3

AT-Series Heating Unit with Filtration

 

 

 

 

 

 

 

 

 

 

 

 

 

K

 

 

 

DA

 

 

 

 

DA

 

DISCHARGE PLENUM

DA

 

DA

 

 

 

 

 

 

 

 

 

H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EXTENSIONS

(OPTIONAL)

J

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F

 

 

 

 

F

 

 

 

 

 

 

LIFTING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ANGLES

 

 

 

 

 

 

 

 

CONTROL

 

 

D

 

 

 

INSPECTION

 

 

 

 

 

PANEL

EXCHANGERHEAT

SECTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AND RELIEF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PORT

 

 

 

 

 

 

PROPELLER FAN / INLET

 

 

 

 

 

 

SPLIT

 

 

 

 

E

 

SECTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FOR

 

 

 

 

 

 

 

 

 

 

SHIPMENT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EXTERIOR

FILTER RACKS

C

 

 

 

 

RA

 

 

 

 

RA

 

RA

 

RA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

 

 

 

 

L

 

 

 

 

G

L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M

 

 

A

 

M

 

 

 

 

 

 

B

 

 

 

 

FRONT VIEW

 

 

 

 

 

 

 

END VIEW

 

 

 

 

DIMENSIONS

 

 

 

 

 

 

LEGEND

 

AT-136 AT-148 AT-154

AT-236 AT-242 AT-248

AT-254

AT-260

AT-272

 

DA = Discharge Air

A

60

72

85

90

100

116

145

160

165

 

 

RA = Return Air

 

B

50

60

72

50

55

60

72

84

90

 

 

 

 

 

 

 

 

C

75

75

86

60

66

66

72

72

76

 

 

 

 

 

 

 

 

 

 

 

75 - 53

 

 

 

 

 

IMPORTANT NOTES:

 

 

 

 

 

75 - 53 100 - 53

 

 

 

 

 

D

53

53

65

53

100 - 53

125 - 72

90

96

96

 

 

 

 

 

 

 

125 - 72

150 - 72

 

 

 

 

 

All dimensions are in inches.

 

 

 

 

 

 

175 - 72

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

All dimensions are subject to change

E

35

35

35

35

35

35

35

35

35

 

 

 

 

without notice.

 

 

45 - 6

45 - 6

45 - 6

45 - 6

75 - 6

75 - 6

175 - 12 300 - 14

300 - 14

 

 

Due to height of unit, additional support is

 

75 - 6

75 - 6

75 - 6

70 - 6

100 - 8

100 - 8

225 - 12 450 - 16

450 - 16

F

recommended on top of the unit.

100 - 8

100 - 8 100 - 8

100 - 8

125 - 10 125 - 10

300 - 14

 

 

 

 

 

 

 

 

 

Dimension "F" is flue

diameter. Flue located

 

 

 

125 - 10

 

 

175 - 12

 

 

 

 

 

G

3

3

3

3

3

3

4

4

4

 

 

on left side of unit for 1,000 MBH heat

H

24

24

36

24

30

30

36

36

40

 

 

exchanger and smaller; flue located on right

J

48

48

48

48

48

48

48

48

48

 

 

side of unit for 1,250 MBH heat exchanger

K

.75

.75

.75

.75

.75

.75

.75

.75

.75

 

 

and larger.

 

L

.75

.75

.75

.75

.75

.75

.75

.75

.75

 

 

Dimensions "D" and "F" may vary depending

M

6

6

6

6

6

6

6

6

6

 

 

on heat exchanger size (ex. 45 = 450 MBH

N

3

3

3

3

3

3

3

3

3

 

 

heat exchanger).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

Image 3
Contents Combat AT-Series Indirect-Fired Air Turnover Units Dimension Selection GuideAT-Series Heating Unit DimensionsAT-Series Heating Unit with Filtration END View AT-Series Cooling Unit with FiltrationFront View END View AT-Series Heating and Cooling Unit with FiltrationEstimated Shipping Weights Burners ALL Models AT-Series Selection GuideTables a Air Turnover Heating Unit Performance Information 10,000 European Office

AT-248, AT-136, AT-236, AT-154, AT-148 specifications

Roberts Gorden, a prominent manufacturer in the heating and ventilation industry, offers a range of advanced infrared heating solutions designed for commercial and industrial applications. Among its diverse portfolio, the AT series, specifically the AT-148, AT-242, AT-136, AT-254, and AT-260, stands out for its efficiency and innovative features.

The Roberts Gorden AT series is renowned for its advanced radiant heating technology. These heaters operate by directly warming objects and people in the space, rather than just the air. This results in lower energy consumption and enhanced comfort levels, making them ideal for large open areas such as warehouses, manufacturing facilities, and gymnasiums.

One of the key features of these models is their high thermal efficiency. The AT series is designed to offer significant energy savings compared to conventional heating methods. With efficient burner systems and reflective surfaces, these heaters can operate at high efficiency, ensuring that a greater percentage of the fuel used is converted into useful heat.

The AT-148, for instance, is known for its compact design, making it suitable for spaces with limited installation options. Despite its small size, it delivers powerful heating performance. The AT-242 and AT-254 models offer larger heating capacities, making them well-suited for expansive areas that require uniform heat distribution. The AT-260 model stands out for its ability to deliver high output even in challenging environments.

Each model in the AT series is equipped with advanced control systems, allowing for precise temperature regulation and energy management. This feature ensures that users can adapt heating output based on occupancy and specific needs, further enhancing energy efficiency.

Durability is another hallmark of the Roberts Gorden AT series. Constructed with high-quality materials, these heaters are built to withstand harsh industrial environments. Their robust design ensures a long lifespan with minimal maintenance requirements.

In summary, the Roberts Gorden AT-148, AT-242, AT-136, AT-254, and AT-260 models exemplify innovation in radiant heating technology. Featuring high efficiency, advanced control systems, and durable construction, they are engineered to provide optimal heating solutions for a variety of commercial and industrial settings. Whether for large warehouses or specialized industrial applications, the AT series offers a reliable and energy-efficient heating option.