Toshiba RAV-SP180UT-UL Selection of Installation Place, Avoid installing in the following places

Page 6

4-way Air Discharge Cassette Type

Installation Manual

3 SELECTION OF INSTALLATION PLACE

WARNING

Install the air conditioner at enough strong place to withstand the weight of the unit. If the strength is not enough, the unit may fall down resulting in injury.

Install the air conditioner at a height 8’ (2.4 m) or more from the floor.

If you insert your hands or others directly into the unit while the air conditioner operates, it is dangerous because you may contact with revolving fan or active electricity.

CAUTION

Do not install the air conditioner in a location subject to a risk of exposure to a combustible gas. If a combustible gas leaks and stays around the unit, a fire may occur.

Upon approval of the customer, install the air conditioner in a place that satisfies the following conditions.

Place where the unit can be installed horizontally.

Place where a sufficient servicing space can be ensured for safety maintenance and check.

Place where drained water will not cause any problem.

Avoid installing in the following places.

Place exposed to air with high salt content (seaside area), or place exposed to large quantities of sulfide gas (hot spring).

(Should the unit be used in these places, special protective measures are needed.)

A restaurant kitchen where a lot of oil is used or place near machines in a factory (Oil adhering to the heat exchanger and resin part (turbo fan) in the indoor unit may reduce the performance, generate mist or dew drop, or deform or damage resin parts.)

Place where organic solvent is used nearby.

Place close to a machine generating high frequency.

Place where the discharged air blows directly into the window of the neighbor house. (Outdoor unit)

Place where noise of the outdoor unit is easily transmitted.

(When install the outdoor unit on the boundary with the neighbor, pay due attention to the level of noise.)

Place with poor ventilation. (Before air ducting work, check whether value of fan speed, static pressure and duct resistance are correct.)

Do not use the air conditioner for special purposes such as preserving food, precision instruments, or art objects, or where breeding animals or growing plants are kept. (This may degrade the quality of preserved materials.)

Place where any of high-frequency appliances (including inverter devices, private power generators, medical equipment, and communication equipment) and inverter-type fluorescent light is installed.

(A malfunction of the air conditioner, abnormal control, or problems due to noise to such appliances/equipment may occur.)

When the wireless remote control is used in a room equipped with an inverter-type fluorescent light or at a place exposed to direct sunlight, signals from the remote control may not be received correctly.

Place near a door or window exposed to humid outside air (Dew droping may form.).

Place where special spray is used frequently.

5-EN

– 5 –

Image 6
Contents Installation Manual Contents „ Separate sold parts Accessory Parts„ Accessory parts Part name ’ty Shape UsagePrecautions for Safety Way Air Discharge Cassette Type Selection of Installation Place Avoid installing in the following placesAdvice „ Installation space„ Selection of installation place Model RAV„Ceiling height Height list of ceiling possible to be installedModel RAV Possible installed ceiling height Unit ft m„ Discharge direction Installation „External viewUnit in mm „ Opening a ceiling and installation of hanging bolts Cushion may damage the fan motor „ Installation of ceiling panel Sold separately „ Installation of remote control Sold separately„ Wireless remote control „ Flexible hose Drain Piping Work„ Piping/Heat insulating material Piping„ Connecting drain pipe „ Drain up„ Check the draining „ Perform heat insulating „Pipe size Refrigerant Piping and Evacuating„ Refrigerant Piping „Permissible Piping Length and Height Difference„ Evacuation Union Pipe Accessory Remote control wiring WiringElectrical Connection „ Wire connection Thermal insulation to wiring connecting port„ Remote Control Wiring „ System interconnection wires and ground wire„ Wiring on the ceiling panel „ Wiring diagram„ Changing applicable control setting ProcedureApplicable Controls Restore the factory default „ Using wireless remote control„ Installing indoor unit on high ceiling Setup data SW501-1 SW501-2„ Filter sign setting „ To secure better effect of heating„ Horizontal louver direction „ Swing mode Swing setup code Swing of louversSetting data 0002 0003 0004 „ Cancel louver lock„ Power saving mode „ Louver lock No swingCode No Data name „ Remote control switch monitoring functionOutdoor unit data Indoor unit dataProcedure example Group control for system of multiple unitsGroup control in single system 29-EN 30-EN „ Before test run Wired remote controlTest RUN „ Execute a test runHeating test run Wireless remote controlCooling test run Cooling test run Heating test run10TROUBLESHOOTING „ Confirmation of error history„ Confirmation and check „ Check codes and parts to be checked IPDU-CDB35-EN 36-EN EH99864701

RAV-SP180UT-UL specifications

The Toshiba RAV-SP180UT-UL is a cutting-edge commercial air conditioning unit designed to deliver exceptional cooling and heating performance. As part of Toshiba's advanced lineup of air conditioning systems, this model caters to diverse applications such as offices, retail spaces, and other commercial environments, ensuring comfortable conditions year-round.

One of the standout features of the RAV-SP180UT-UL is its powerful inverter technology. This technology enables the unit to adjust its cooling or heating output based on the current load requirements, resulting in significant energy savings and improved efficiency compared to conventional systems. It operates with a high Seasonal Energy Efficiency Ratio (SEER) and a Heating Seasonal Performance Factor (HSPF), making it an environmentally friendly choice for businesses seeking to reduce their carbon footprint.

Another key characteristic of the RAV-SP180UT-UL is its ultra-quiet operation. The unit is designed to minimize noise levels, providing a serene indoor environment that is ideal for workplaces and customer-facing areas. This low-noise performance is achieved through advanced fan engineering and acoustic insulation, ensuring that disruptions to work or leisure activities are kept to a minimum.

The RAV-SP180UT-UL also features flexible installation options, allowing for wall-mounted or ceiling-mounted configurations to suit various spatial requirements. Its compact design means that it can be installed in tight spaces without compromising on performance or aesthetics. The unit is equipped with a remote control for added convenience, enabling users to easily adjust settings, set timers, and switch between modes.

Moreover, the Toshiba RAV-SP180UT-UL is built with durability in mind. It utilizes high-quality materials and components that ensure long-lasting performance, even in demanding environments. The unit is also equipped with advanced filtration systems that enhance indoor air quality by removing dust, allergens, and other contaminants, contributing to a healthier workplace.

In summary, the Toshiba RAV-SP180UT-UL is a reliable and efficient solution for commercial air conditioning needs. Its inverter technology, quiet operation, flexible installation, and emphasis on durability make it a compelling choice for businesses looking to enhance comfort while maintaining energy efficiency. Whether for heating or cooling, this unit delivers consistent performance that meets the demands of modern commercial settings.