York E*BD-(T Accessories, Installation Clearances, Sound Power Ratings, Typical Field Wiring, Dba

Page 17

ACCESSORIES

Refer to Price Manual for specific model numbers.

Start Assist Kit (2SA067*)

Blower Time Delay - Available to increase efficiency when installed. Installs on indoor section and maintains blower for approximately one minute after cooling thermostat has been satisfied.

Hard Start Kits - Provides required starting torque for use with Thermal Expansion Valve Kit.

Low Temperature Cutout (2LT06700224) - Prevents heat pump operation below -10°F ambient temperature.

Compressor Blanket - Designed to further reduce the nor- mal operating sound.

Add-on Fossil Fuel Control - Interface controls for use with gas, oil furnaces and the heat pump system are available.

Thermal Expansion Valve Kit - 1TVM700 Series TXV kit used to improve system performance.

Outdoor Thermostat (2TD06700124) - Provides additional staging of supplemental electric heat.

INSTALLATION CLEARANCES

246819-BTG-H-0208

Room Thermostats - A wide selection of matching thermo- stats is available to provide features required for any installa- tion.

2H/1C, manual changeover electronic non-programmable thermostat.

3H/2C, non-programmable digital thermostat.

3H/2C, auto/manual changeover, electronic programmable, 7-day, hardwire thermostat.

*For the most current accessory information, refer to the price book or consult factory.

SOUND POWER RATINGS

UNIT MODEL

 

(dBA)*

 

 

 

 

Cooling

 

Heating

018

73

 

72

024

75

 

76

030

74

 

76

036

76

 

77

042

77

 

78

048

78

 

78

060

79

 

79

* Rated in accordance with ARI 270-95 Standards.

 

MINIMUM 18” SERVICE ACCESS

THERMOSTAT

TO FURNACE OR

60” OVERHEAD

CLEARANCE ON ONE SIDE

 

 

AIR HANDLER

CLEARANCE

WEATHERPROOF

 

 

TERMINAL BLOCK

 

DISCONNECT

 

 

 

 

 

SWITCH

 

NEC CLASS 1 WIRING

 

 

 

NEC CLASS 2 WIRING

10” CLEARANCE

 

 

TO INDOOR COIL

COIL AREA

 

 

NOTE: ALL OUTDOOR WIRING MUST BE WEATHERPROOF.

SEAL OPENING(S) WITH

PERMAGUM OR EQUIVALENT

CONTROL ACCESS PANEL

TYPICAL FIELD WIRING

ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES

THERMOSTAT

INDOOR UNIT

 

R

 

B

or C

 

 

Y

 

 

O

 

 

W

 

L or X

 

 

G

1 FIELD

 

2

 

T

INSTALLED

 

E2

JUMPER

JUMPER TERMINALS E AND W TOHEAT

ON FIRST STAGE DURING EMERGENCY HEAT.

TERMINAL NOT USED ON ALL THERMOSTATS.

POWER WIRING

24V CONTROL WIRING (NEC CLASS 2)

 

DEFROST

 

 

 

 

CONTROL

 

 

 

R

RED

R

 

 

 

C

BLK

C

CONTACTOR

 

 

 

Y

YEL

 

 

Y

T2

 

 

O

ORG

O

T1

 

W2

BRN

W

 

M

GND.

 

PUR

X/L

L2

L1

 

SCREW

G

WHT W1/66

W1

5GRY CC

BK

DEHUMIDIFICATION CONTROL CONNECTION (Humidistat* Jumper must be removed)

GND.

LUG

 

POWER WIRING

 

208/230-1-60

CIRCUIT

230-1-50

 

BREAKER***

 

3CHECK THE LOW VOLTAGE TERMINAL BLOCK ON THE INDOOR UNIT FOR THE ACTUAL ARRANGEMENT OF THE TERMINALS.

4CONNECT POWER WIRING TO TERMINAL BLOCK 3TB ON UNITS WITHOUT ELECTRIC HEAT OR CIRCUIT BREAKER.

5GRAY FOR USE WITH OPTIONAL OUTDOOR THERMOSTAT KITS.

Unitary Products Group

17

Image 17
Contents Description WarrantyFeatures Model Physical and Electrical Data 1 PhaseUnit ModelIndoor Coil1,2 Footnotes ProceduresIndoor Coil 1,2 Dimensions Physical and Electrical Data 3 PhaseIndoor Coil1 Sens Cooling Capacity With Air Handler CoilsPH 13 Seer HP With MARated NET MBH Model Seer EER CFM Unit AIR Handler CoolingPH 13 Seer AC with AV / SV Variable Speed Seer HP with AHP / F*FP / F*FVFC/MC/PC/UC18 Sens PH 13 Seer HP with Variable Speed FURNACES2 Cooling Capacity With Variable Speed FurnacesFC/MC/PC60D Unit AIR COIL1 ARI HEATING2 Model Handler Heating Performance With Air HandlerPH 13 Seer HP with MA Seer HP with MVPH HP Seer AC with AHP / F*FP / F*FV Seer HP with AVUnit COIL1 ARI HEATING2 Model Heating Performance Upflow Furnace CoilsModel Furnace Heating Capacity With Variable Speed FurnacesUnit Variable COIL1 ARI HEATING2 Speed Unit Variable COIL1 ARI HEATING2 Speed Model Installation Clearances AccessoriesSound Power Ratings Typical Field WiringCooling Performance Data TemperatureCondenser Entering AIRMA08B FC/MC24B FC/MC30B AHP24 Indoor Coil Model no FC/MC/PC35 Outdoor Unit Model noIndoor Coil Model no FC/MC/PC/UC48 EABD-F042S, EABD-T,W042S Indoor Coil Model no FC/MC/PC/UC60 EABD-F060S, EABD-T,W060S Outdoor Unit Indoor Coil Heating Performance DataEntering MBH COP Evaporator Coil Model no FC/MC/PC35 Condensing Unit Model noEvaporator Coil Model no FC/MC/PC/UC48 51.7 Evaporator Coil Model no FC/MC/PC/UC60 72.1 Unitary 5005 Norman Product York Group Drive 73069

E*BD-(T, E*BD-F018 THRU 060, W)036 THRU 060 specifications

The York W)036 THRU 060, E*BD-F018 THRU 060, E*BD-(T series represents a significant advancement in commercial HVAC solutions, designed to meet the varied needs of large spaces that require efficient climate control. These units are particularly suited for industrial and institutional applications, where reliability and performance are paramount.

One of the main features of this series is its energy efficiency. With advanced engineering, these HVAC systems achieve a high Energy Efficiency Ratio (EER) and Seasonal Energy Efficiency Ratio (SEER), which in turn helps businesses reduce their energy bills while minimizing their environmental footprint. The systems are equipped with high-efficiency compressors and optimized refrigerant management strategies to maximize operational effectiveness.

Furthermore, the W)036 THRU 060, E*BD models are designed for flexibility in installation and integration. They can accommodate various building layouts and are compatible with multiple ventilation configurations. This adaptability makes them suitable for warehouses, educational institutions, and large retail facilities.

The technology embedded within these units is state-of-the-art. They include microprocessor-based controls that provide precise temperature management and real-time diagnostics. This smart technology facilitates easier scheduling and monitoring, allowing facility managers to optimize performance according to demand. Additionally, with features such as variable speed fan motors, these systems are able to adjust airflow based on real-time conditions, further enhancing comfort levels while saving energy.

Durability is another hallmark of the W)036 THRU 060, E*BD series. Constructed with robust materials, these units are designed to withstand the rigors of commercial use while requiring minimal maintenance. This reliability ensures that operations remain uninterrupted, which is critical for businesses that rely on consistent climate control.

In terms of environmental impact, these units adhere to stringent industry standards. They utilize eco-friendly refrigerants, which not only comply with regulations but also contribute to lower greenhouse gas emissions.

In summary, the York W)036 THRU 060, E*BD-F018 THRU 060, E*BD-(T series is a prime example of advanced HVAC technology. With features highlighting energy efficiency, flexible installation options, smart technology, and durability, these units are engineered to deliver reliable performance, making them an ideal choice for any commercial application needing superior climate control.