York W)036 THRU 060, E*BD-(T Cooling Performance Data, Condenser, Entering AIR, Temperature

Page 18

246819-BTG-H-0208

COOLING PERFORMANCE DATA

OUTDOOR UNIT MODEL NO.

EABD-F018S

 

 

 

 

 

 

 

 

 

 

 

 

INDOOR COIL MODEL NO.

FC/MC/PC/UC18

 

 

 

 

 

 

 

 

 

 

 

 

CONDENSER

ID CFM

 

 

450

 

 

 

 

600

 

 

 

 

750

 

 

ENTERING AIR

ID DB (°F)

80

80

75

80

80

80

80

75

80

80

80

80

75

80

80

TEMPERATURE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ID WB (°F)

57

62

62

67

72

57

62

62

67

72

57

62

62

67

72

 

T.C.

16.8

19.2

19.5

21.9

24.5

19.0

20.7

20.8

23.1

25.8

21.2

22.3

22.1

24.3

27.1

65

S.C.

16.3

14.4

12.7

12.8

10.8

18.4

16.9

14.7

14.6

12.3

20.6

19.5

16.8

16.4

13.8

 

K.W.

1.1

1.1

1.1

1.1

1.1

1.1

1.1

1.1

1.1

1.1

1.1

1.1

1.1

1.1

1.1

 

T.C.

16.1

18.1

18.3

20.6

23.2

18.1

19.5

19.4

21.8

24.3

20.1

20.9

20.6

23.0

25.4

75

S.C.

15.6

13.9

12.1

12.3

10.3

17.6

16.3

14.1

14.0

11.7

19.5

18.8

16.0

15.8

13.0

 

K.W.

1.2

1.2

1.2

1.2

1.2

1.2

1.2

1.2

1.2

1.2

1.2

1.2

1.2

1.2

1.3

 

T.C.

15.4

17.1

17.0

19.2

21.8

17.2

18.3

18.1

20.4

22.7

19.0

19.6

19.2

21.6

23.6

85

S.C.

14.9

13.4

11.5

11.7

9.8

16.7

15.7

13.4

13.5

11.0

18.5

18.1

15.3

15.3

12.2

 

K.W.

1.2

1.3

1.3

1.3

1.3

1.3

1.3

1.3

1.3

1.3

1.3

1.3

1.3

1.3

1.4

 

T.C.

14.8

16.0

15.8

17.9

20.4

16.3

17.1

16.8

19.1

21.2

17.9

18.3

17.7

20.3

21.9

95

S.C.

14.2

12.9

10.9

11.1

9.3

15.8

15.1

12.7

12.9

10.4

17.5

17.4

14.6

14.7

11.4

 

K.W.

1.3

1.3

1.3

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.5

 

T.C.

14.0

14.9

14.7

16.8

19.1

15.4

16.0

15.6

17.8

19.7

16.9

17.0

16.5

18.7

20.4

105

S.C.

13.5

12.5

10.4

10.7

8.8

15.0

14.5

12.2

12.4

9.9

16.4

16.6

14.0

14.1

10.9

 

K.W.

1.4

1.4

1.4

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.6

 

T.C.

13.3

13.9

13.7

15.7

17.8

14.5

14.9

14.5

16.4

18.4

15.8

15.8

15.3

17.2

19.0

115

S.C.

12.8

12.0

9.9

10.2

8.3

14.1

13.9

11.7

11.8

9.4

15.4

15.8

13.4

13.4

10.5

 

K.W.

1.5

1.5

1.5

1.6

1.6

1.5

1.6

1.5

1.6

1.6

1.6

1.6

1.6

1.6

1.7

 

T.C.

12.5

12.9

12.7

14.6

16.5

13.7

13.7

13.4

15.1

17.0

14.8

14.5

14.1

15.7

17.5

125

S.C.

12.0

11.6

9.4

9.8

7.8

13.2

13.3

11.1

11.3

8.9

14.4

15.1

12.8

12.8

10.0

 

K.W.

1.6

1.6

1.6

1.7

1.7

1.6

1.6

1.6

1.7

1.7

1.7

1.7

1.7

1.7

1.8

NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.

Multipliers for determining the performance with other indoor sections.

NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.

Air Handler

Coil

T.C.

S.C.

KW

 

 

 

 

 

MA08B

FC/MC18B

1.00

1.00

1.00

 

 

 

 

 

AHP18

1.00

0.92

1.00

 

 

 

 

 

F*FP024

1.00

0.92

1.00

 

 

 

 

 

MV12B

FC/MC18B

1.02

1.02

0.98

 

 

 

 

 

AV24

1.02

1.02

0.98

 

 

 

 

 

HC18

0.99

0.98

0.99

 

 

 

 

 

Variable Speed

Coil

T.C.

S.C.

KW

Furnace

 

 

 

 

(F,L)L8VA12

FC/MC/PC18A

1.02

1.01

0.97

FL9VA12

FC/MC/PC18A

1.02

1.01

0.97

FL9(C,V)B12

FC/MC/PC18B

1.03

1.02

0.98

(F,L)L8VA12

HC18

1.02

1.01

0.97

FL9VA12

HC18

1.02

1.01

0.97

18

Unitary Products Group

Image 18
Contents Warranty FeaturesDescription Unit Physical and Electrical Data 1 PhaseModel ModelIndoor Coil1,2 Procedures Indoor Coil 1,2Footnotes Physical and Electrical Data 3 Phase DimensionsIndoor Coil1 PH 13 Seer HP Cooling Capacity With Air Handler CoilsSens With MAPH 13 Seer AC with AV / SV Variable Speed Unit AIR Handler CoolingRated NET MBH Model Seer EER CFM Seer HP with AHP / F*FP / F*FVFC/MC/PC/UC18 Cooling Capacity With Variable Speed Furnaces Sens PH 13 Seer HP with Variable Speed FURNACES2FC/MC/PC60D PH 13 Seer HP with MA Heating Performance With Air HandlerUnit AIR COIL1 ARI HEATING2 Model Handler Seer HP with MVSeer HP with AV PH HP Seer AC with AHP / F*FP / F*FVHeating Performance Upflow Furnace Coils Unit COIL1 ARI HEATING2 ModelHeating Capacity With Variable Speed Furnaces Unit Variable COIL1 ARI HEATING2 SpeedModel Furnace Unit Variable COIL1 ARI HEATING2 Speed Model Sound Power Ratings AccessoriesInstallation Clearances Typical Field WiringCondenser TemperatureCooling Performance Data Entering AIRMA08B FC/MC24B FC/MC30B AHP24 Outdoor Unit Model no Indoor Coil Model no FC/MC/PC35Indoor Coil Model no FC/MC/PC/UC48 EABD-F042S, EABD-T,W042S Indoor Coil Model no FC/MC/PC/UC60 EABD-F060S, EABD-T,W060S Heating Performance Data EnteringOutdoor Unit Indoor Coil MBH COP Condensing Unit Model no Evaporator Coil Model no FC/MC/PC35Evaporator Coil Model no FC/MC/PC/UC48 51.7 Evaporator Coil Model no FC/MC/PC/UC60 72.1 Unitary 5005 Norman Product York Group Drive 73069

E*BD-(T, E*BD-F018 THRU 060, W)036 THRU 060 specifications

The York W)036 THRU 060, E*BD-F018 THRU 060, E*BD-(T series represents a significant advancement in commercial HVAC solutions, designed to meet the varied needs of large spaces that require efficient climate control. These units are particularly suited for industrial and institutional applications, where reliability and performance are paramount.

One of the main features of this series is its energy efficiency. With advanced engineering, these HVAC systems achieve a high Energy Efficiency Ratio (EER) and Seasonal Energy Efficiency Ratio (SEER), which in turn helps businesses reduce their energy bills while minimizing their environmental footprint. The systems are equipped with high-efficiency compressors and optimized refrigerant management strategies to maximize operational effectiveness.

Furthermore, the W)036 THRU 060, E*BD models are designed for flexibility in installation and integration. They can accommodate various building layouts and are compatible with multiple ventilation configurations. This adaptability makes them suitable for warehouses, educational institutions, and large retail facilities.

The technology embedded within these units is state-of-the-art. They include microprocessor-based controls that provide precise temperature management and real-time diagnostics. This smart technology facilitates easier scheduling and monitoring, allowing facility managers to optimize performance according to demand. Additionally, with features such as variable speed fan motors, these systems are able to adjust airflow based on real-time conditions, further enhancing comfort levels while saving energy.

Durability is another hallmark of the W)036 THRU 060, E*BD series. Constructed with robust materials, these units are designed to withstand the rigors of commercial use while requiring minimal maintenance. This reliability ensures that operations remain uninterrupted, which is critical for businesses that rely on consistent climate control.

In terms of environmental impact, these units adhere to stringent industry standards. They utilize eco-friendly refrigerants, which not only comply with regulations but also contribute to lower greenhouse gas emissions.

In summary, the York W)036 THRU 060, E*BD-F018 THRU 060, E*BD-(T series is a prime example of advanced HVAC technology. With features highlighting energy efficiency, flexible installation options, smart technology, and durability, these units are engineered to deliver reliable performance, making them an ideal choice for any commercial application needing superior climate control.