York E*BD-F018 THRU 060, W)036 THRU 060, E*BD-(T Unit Variable COIL1 ARI HEATING2 Speed Model

Page 16

246819-BTG-H-0208

HEATING CAPACITY - With Variable Speed Furnaces (Continued)

UNIT

VARIABLE

COIL1

 

 

ARI HEATING2

 

 

SPEED

 

 

 

 

 

 

 

MODEL

MODEL

 

47°F

 

 

17°F

 

HSPF

FURNACE

 

 

 

 

 

 

 

 

 

MBH

COP

KW

MBH

COP

KW

STD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(F,L)L8VC20

FC/MC/PC48C

41.5

3.70

3.29

24.6

2.62

2.75

8.75

 

FL9(C,V)C16

FC/MC/PC48C

41.5

3.70

3.29

24.6

2.60

2.77

8.75

 

FL9(C,V)C20

FC/MC/PC48C

41.0

3.76

3.19

24.2

2.66

2.67

8.75

EABD-F042S

 

 

 

 

 

 

 

 

 

FL9(C,V)D20

FC/MC/PC48D

41.0

3.80

3.16

24.2

2.68

2.65

8.75

 

(F,L)L8VC20

HD48

41.5

3.72

3.27

24.6

2.64

2.71

8.75

 

FL9(C,V)C16

HD48

41.5

3.70

3.29

24.4

2.60

2.77

8.75

 

FL9(C,V)C20

HD48

41.5

3.70

3.29

24.4

2.62

2.75

8.75

 

FL9(C,V)D20

FC/MC/PC60D

47.5

3.54

3.93

29.4

2.36

3.65

8.20

 

(F,L)L8VC16

FC/PC60C

47.5

3.50

3.98

29.4

2.34

3.68

8.10

 

(F,L)L8VC20

FC/PC60C

47.5

3.54

3.93

29.4

2.36

3.65

8.20

 

FL9(C,V)C16

FC/PC60C

47.0

3.50

3.93

29.6

2.34

3.71

8.15

EABD-F048S

 

 

 

 

 

 

 

 

 

FL9(C,V)C20

FC/PC60C

47.5

3.52

3.95

29.6

2.36

3.67

8.20

 

FL9(C,V)C20

HC60

47.5

3.52

3.95

29.4

2.36

3.67

8.20

 

(F,L)L8VC20

HD60

47.5

3.54

3.93

29.4

2.36

3.65

8.20

 

FL9(C,V)C20

HD60

47.5

3.52

3.95

29.6

2.36

3.67

8.20

 

FL9(C,V)D20

MC61D

47.5

3.56

3.91

29.4

2.36

3.65

8.20

 

FL9(C,V)D20

FC/MC/PC60D

56.0

3.56

4.61

34.0

2.34

4.26

8.15

 

(F,L)L8VC20

FC/PC60C

57.5

3.54

4.76

34.6

2.32

4.37

8.10

 

FL9(C,V)C20

FC/PC60C

57.0

3.52

4.83

34.2

2.32

4.32

8.10

EABD-F060S

 

 

 

 

 

 

 

 

 

FL9(C,V)D20

HC60

56.0

3.56

4.65

34.0

2.32

4.29

8.15

 

(F,L)L8VC20

HD60

56.0

3.54

4.76

34.0

2.32

4.34

8.15

 

FL9(C,V)D20

HD60

56.0

3.56

4.65

34.0

2.34

4.26

8.15

 

FL9(C,V)D20

MC61D

56.0

3.56

4.61

34.0

2.34

4.26

8.15

1.Rated CFM same as for cooling.

2.Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no supplemental electric heat operation.

CP equals MBH output divided by (total KW input x 3.412).

HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period.

— = Not Applicable.

16

Unitary Products Group

Image 16
Contents Features WarrantyDescription Physical and Electrical Data 1 Phase ModelUnit ModelIndoor Coil1,2 Indoor Coil 1,2 ProceduresFootnotes Physical and Electrical Data 3 Phase DimensionsIndoor Coil1 Cooling Capacity With Air Handler Coils SensPH 13 Seer HP With MAUnit AIR Handler Cooling Rated NET MBH Model Seer EER CFMPH 13 Seer AC with AV / SV Variable Speed Seer HP with AHP / F*FP / F*FVFC/MC/PC/UC18 Cooling Capacity With Variable Speed Furnaces Sens PH 13 Seer HP with Variable Speed FURNACES2FC/MC/PC60D Heating Performance With Air Handler Unit AIR COIL1 ARI HEATING2 Model HandlerPH 13 Seer HP with MA Seer HP with MVSeer HP with AV PH HP Seer AC with AHP / F*FP / F*FVHeating Performance Upflow Furnace Coils Unit COIL1 ARI HEATING2 ModelUnit Variable COIL1 ARI HEATING2 Speed Heating Capacity With Variable Speed FurnacesModel Furnace Unit Variable COIL1 ARI HEATING2 Speed Model Accessories Installation ClearancesSound Power Ratings Typical Field WiringTemperature Cooling Performance DataCondenser Entering AIRMA08B FC/MC24B FC/MC30B AHP24 Outdoor Unit Model no Indoor Coil Model no FC/MC/PC35Indoor Coil Model no FC/MC/PC/UC48 EABD-F042S, EABD-T,W042S Indoor Coil Model no FC/MC/PC/UC60 EABD-F060S, EABD-T,W060S Entering Heating Performance DataOutdoor Unit Indoor Coil MBH COP Condensing Unit Model no Evaporator Coil Model no FC/MC/PC35Evaporator Coil Model no FC/MC/PC/UC48 51.7 Evaporator Coil Model no FC/MC/PC/UC60 72.1 Unitary 5005 Norman Product York Group Drive 73069

E*BD-(T, E*BD-F018 THRU 060, W)036 THRU 060 specifications

The York W)036 THRU 060, E*BD-F018 THRU 060, E*BD-(T series represents a significant advancement in commercial HVAC solutions, designed to meet the varied needs of large spaces that require efficient climate control. These units are particularly suited for industrial and institutional applications, where reliability and performance are paramount.

One of the main features of this series is its energy efficiency. With advanced engineering, these HVAC systems achieve a high Energy Efficiency Ratio (EER) and Seasonal Energy Efficiency Ratio (SEER), which in turn helps businesses reduce their energy bills while minimizing their environmental footprint. The systems are equipped with high-efficiency compressors and optimized refrigerant management strategies to maximize operational effectiveness.

Furthermore, the W)036 THRU 060, E*BD models are designed for flexibility in installation and integration. They can accommodate various building layouts and are compatible with multiple ventilation configurations. This adaptability makes them suitable for warehouses, educational institutions, and large retail facilities.

The technology embedded within these units is state-of-the-art. They include microprocessor-based controls that provide precise temperature management and real-time diagnostics. This smart technology facilitates easier scheduling and monitoring, allowing facility managers to optimize performance according to demand. Additionally, with features such as variable speed fan motors, these systems are able to adjust airflow based on real-time conditions, further enhancing comfort levels while saving energy.

Durability is another hallmark of the W)036 THRU 060, E*BD series. Constructed with robust materials, these units are designed to withstand the rigors of commercial use while requiring minimal maintenance. This reliability ensures that operations remain uninterrupted, which is critical for businesses that rely on consistent climate control.

In terms of environmental impact, these units adhere to stringent industry standards. They utilize eco-friendly refrigerants, which not only comply with regulations but also contribute to lower greenhouse gas emissions.

In summary, the York W)036 THRU 060, E*BD-F018 THRU 060, E*BD-(T series is a prime example of advanced HVAC technology. With features highlighting energy efficiency, flexible installation options, smart technology, and durability, these units are engineered to deliver reliable performance, making them an ideal choice for any commercial application needing superior climate control.