Toshiba RAS-10JKCVP Timer on, Timer off, Daily timer, For timer on on For timer off, Select SET

Page 20

Timer on, Timer off

Start and stop of operation is selected with the time. Operate after setting the current time on the remote controller. Page 9

1

2

 

 

Example of setting

For timer on ON

For timer off

(Selection of timer On/Off)

OFF

 

 

To start at 6:00 AM and

 

 

stop at 10:00 AM.

1

ON

Adjust the time to the starting (stopping) time.

Forward

2

Select operation start for 6:00 AM.

TEMP.

Forward

 

TEMP.

Backward

Changes by 10 minutes when pressed once and by 1 hour when pressed continuously.

The selected time is displayed

Go to 3 if the same time as a previous setting can be used.

3 Select SET

During timer off, automatic filter cleaning operation starts after the operation stops at the selected time. Drying inside is not performed.

Automaticis set. cleaning is not performed after air conditioner stops in case of Off/On timer

Timer off can be selected with the previous operation setting even while stopped. The operation starts when selected.

3

4

5

Backward

Selected time and current operating mode blink alternately in the pictographic character display portion.

SET

OFF

Set the stop time to 10:00 AM.

Forward

TEMP.

Backward

To cancel

CLR

To change the selected time, press ON or OFF to change the setting.

Daily timer

1 Press

ON

for Timer on setting.

 

2 Press TEMP. for select desired Starting time.

 

3 Press

OFF

for Timer off setting.

 

4 Press TEMP. for select desired Stopping time.

 

5 Press

SET

or

will blink.

 

6 During

 

or

blink, press SET agian and display will show

.

Selected time and current operating mode blink alternately in the pictographic character display portion.

6SET

Daily timer setting is canceled when the Comfort sleep COMFORT is set.

SLEEP

Daily timer setting is canceled when Start and Stop button is pressed.

After operation stops, only automatic filter cleaning functions but drying of inside is not performed.

20

1110650159_(11-20)_EN.indd 20

2/28/11 2:10 PM

Image 20
Contents ‡¼n¤º„µÄŠoµœ Contents Picoion air cleaning Care and cleaningPrecautions For safety When the front panel is opened Parts nameAir inlet Front panel Open-close panel Air filterReal time monitor display Indoor unit displayMemory and recall user setting operation Transmitting partStart and Stop operation Kind of receiving tone CoverRemote control when open cover Comfort sleep displayRemote controller Preparation before operation and checkingTurn on the main power supply Indoor unitWhen starting automatic operation, select a When stopsWhen changing the temperature Temperature Automatic operationEconomic operation activated by active human search sensor Economic operation activated by the brightness search sensorCooling, Dry operation and Fan only operation Fan only operationWhen changing the temperature When stoppingDry OperationPicoion air purifier To clean the airWhen stopping operation Air volume, Fix and Swing When changing the air direction, press FIXSetting for air flow Page 17 When swing, press Swing Every timeComfort air flow Direct air flowWhen adjusting the air direction slightly Wide air flow, spot air flowTimer operation Every time when pressed within 3 secondsTo cancel Comfort sleepTimer on, Timer off Daily timerFor timer on on For timer off Adjust the time to the starting stopping timePreset Operation Set preferred operationEnergy Saving ECO OperationLimit maximum Current and Power consumption Press Hi Power while holding the check button Indoor unit displayAutomatic cleaning To stop automatic cleaning during operationAutomatic cleaning operation More 2 timesCare and cleaning Remote controllerCare of the outside casing Indoor unitCare and cleaning of the front panel and dust box Front panelDust Box Slide the fixing levers 4 points of the dust boxBrush unit Care and cleaning of the air filter and brush unitHow to care Front and back side of the air filter How to removeAir filter Test run after care and cleaning When restarting for usePress again for approx second Close the front panel Check that it is closedWhen the lamp of indoor unit blinks If the lamp blinks again, inspection and repair is requiredAuto Restart Setting If the remote controller is not available Case of 2 air conditioners are installed near each otherAt a time like this Concern about the operating noiseThese are not failures 111065015931-38EN.indd 28/11 211 PM These are not failures Condensation appears ­µ´ „µšÎµŠµœÂ´˜Ãœ¤´˜·Ážiµ¨¤Ã—¥˜Š ¨³„µÁžiµ¨¤ ¨¸„Á¨¸É¥Š³­oµŠž³‹»¨Â¨³³¢„µ„µ« „µ—¼Â¨´„¬µÂ¨³šÎµ‡ªµ¤­³µ—…o‡ª³ª´Š ´œ˜µ¥‡ÎµÁ˜ºœ …o‡ª³ª´ŠºÉœ·Ê­ªnœ ˜´ªÁ‡ºÉŠ£µ¥Äœœoµ‹Â­—Š„µšÎµŠµœž‹‹ »´œ …ŠÁ‡ºÉŠž´µ„µ« ¼žÂ…ŠÁ­¸¥ŠÄœ …–³´­´µ– ­ªnœ´­Šn­´ µ–œš´ „¹¼žÂ„µšÎµŠµœš˜¸ÉoŠ„µ ¨³Á¸¥„čŠoµœ‡nµš˜¸ÉŠ´ÊŪo ž´»–£¼¤·º˜´ª˜Š´ÊÁª¨µ¸Ã¤š‡œÃš¨Á¤ºÉÁž—d µ‡„ ¤µ¥Á˜»¸Ã¤š‡œÃš¨ ˜´ªÁ‡ºÉŠ£µ¥Äœ ž—d¨nŠ‹nµ¥Å¢¢jµ¨´„¸Ê¸Ã¤š‡œÃš¨Åžš˜¸É´ª´­´ µ–·œ¢µÁ—œ˜´ªÁ‡ºÉŠ£µ¥Äœ ³¥³…Š„µ´ ¨³­Šn­´ µ–„µšÎµŠµœÄœÃ¤—´˜Ãœ¤´˜· ¤ºÉ˜oŠ„µÁ·É¤„µšÎµŠµœÄœÃ¤—´˜Ãœ¤´˜·ÄoÁ¨º„ a¤ºÉ¥»—„µšÎµŠµœ ¤ºÉ˜oŠ„µÁž¨¸É¥œÂž¨Š³—´»–£¼¤·¥¨³Á¸¥—…Š„µšÎµŠµœÄœÃ¤—´˜Ãœ¤´˜· ¤—šÎµ‡ªµ¤Á¥œÈ ä—¨—‡ªµ¤œºÊ ¨³Ã¤—¡´—¨¤Á¡¸¥Š¥nµŠÁ—¸¥ª ¤ºÉÁ­¸¥Š žd€žd€ —Š…´ ¹Êœ…œ¹Ê ³¢„µ„µ« šÎµÄoµ„µ«­³µ—×¥œ…–³ž´µ„µ« Šoµœ³ž´µ„µ«Äœ…–³ „—ž»i¤ ³¢„µ„µ«šÎµŠµœ ¥—„» µšÎµŠµœ…Š³¢„µ„µ« „—ž»i¤³—´ÂŠ¨¤Â¨³š·«šµŠ¨¤ ¤ºÉ˜oŠ„µÁž¨¸É¥œ‡nµ³—´ÂŠ¨¤ „— FAN ˜n¨³‡´ÊŠš„—ž¸É »i¤¤ºÉ˜oŠ„µÁž¨¸É¥œš·«šµŠ¨¤ „— FIX „µž´š·«šµŠ¨¤ œoµ 17„µÁžiµ¨¤ÂÁ¥Èœ­µ¥ žiµ¨¤Ã—¥˜Š„³‹µ¥¨¤Á¥ÈœÂ¨³Ážiµ¨¤ÁŒ¡µ³‹—» šnµœ­µ¤µ™Á¨º„¼žÂ„µÁžiµ¨¤ÂÁ¥œÈ­µ¥¨³Ážiµ¨¤Ã—¥˜Š º Ážiµ¨¤Â¨¸„Á¨¸É¥Š ‹µ„ ¤ºÉ˜oŠ„µž´š·«šµŠ¨¤Á¨È„œo¥„µ˜Š´ÊÁª¨µ Comfort sleep„µ˜Š´ÊÁª¨µÁž—d, „µ˜Š´ÊÁª¨µž—d „µ˜Š´ÊÁª¨µ­µ´Îš„»Ç ª´œ„µ˜Š‡´Ê nµ„µšÎµŠµœš¸ÉœºÉ  „µž³¥´—¡¨´ŠŠµœ „µšÎµŠµœÄœÃ¤— ECO„µ‹Îµ„—„´ ³Â­Å¢¢jµÂ¨³´˜µ„µÄo¡¨´ŠŠµœ­Š¼­—» „—ž»i¤ Hi Power ×¥š„—ž¸É »i¤ Check ‡oµŠÅªo „—ž»i¤ Check ‡oµŠÅªoץčoª´­—ž»¨µ¥Â¨¤„¨nŠÁ„È œi» „µšÎµ‡ªµ¤­³µ—´˜Ãœ¤´˜·„µšÎµŠµœ…ŠÃ¤—šÎµ‡ªµ¤­³µ—´˜Ãœ¤´˜· ˜´ªÁ‡ºÉŠ£µ¥Äœ ¸Ã¤š‡œÃš¨ „µ—¼Â¨´„¬µÂ¨³šÎµ‡ªµ¤­³µ—„µ—¼Â¨´„¬µ£µ¥œ„˜´ªÁ‡ºÉŠ „µ—¼Â¨Â¨³šÎµ‡ªµ¤­³µ—œoµ„µ„Á‡ºÉŠž´µ„µ«„„´ ¨nŠÁ„È œi» œoµ„µ„Á‡ºÉŠž´µ„µ«„µž³„ „µšÎµ‡ªµ¤­³µ— „¨nŠÁ„È œi»„µ™—„ „µ—¼Â¨´„¬µÂ¨³šÎµ‡ªµ¤­³µ—Ÿœ„n Šµ„µ«Â¨³ÂžŠ „µ—¼Â¨´„¬µ¨´Š‹µ„šÎµ‡ªµ¤­³µ— Äo—εÁœœ„· µ š—­„µšÎµŠµœ¨´Š„µšÎµ‡ªµ¤­³µ— œoµŸœ„n Šµ„µ« „µ™——oµœœoµÂ¨³—oµœ¨´Š…ŠÂŸœ„n Šµ„µ« ¤µ¥Á˜» ¤n‡ªÄ­oµŽ„´¢„ ÁœºÉŠ‹µ„µ‹šÎµÄo„µšÎµŠµœŸ—ž„˜· ·„—ž»i¤ ¸„‡´ÊŠœµœž³¤µ– 1 ª·œµš¸ ž—dœoµ„µ„Á‡ºÉŠž´µ„µ« ˜ª‹—¼¸„‡´ÊŠªnµž—d¨oª„—ž»i¤ Check œ¸Ã¤š‡oµŠÅªoœµœ„ªnµ 10 ª·œµš¸ ˜ª‹­Å¢Á˜ºœœœoµ‹Â­—Š„µšÎµŠµœ…ŠÁ‡ºÉŠž´µ„µ«„—ž»i¤ Temp ¤ºÉÅ¢œ˜´ªÁ‡ºÉŠ£µ¥Äœ„³¡·žo¨µ¥—œ·­„—ž»i¤ Check Á¡ºÉž´¸Ã¤š‡œÃš¨Á…oµ­Án¼Žrª·­Ã¤— „µ˜Š„´Ê µÁ·É¤šÎµŠµœÄ¤n×¥´˜Ãœ¤´˜· œ„–¸—´Š˜nÅžœ¸Ê œ„–š¸¸ÉŤn¤¸¸Ã¤š‡œÃš¨œ„–š¸¸É¤¸„µ˜—˜· Š´ÊÁ‡ºÉŠž´µ„µ« 2 Á‡ºÉŠÅªoÄ„¨o„œ´ „¸É¥ª„´Á­¥¸Šš¸ÉÁ„—…· œ¹ÊÄœ³ªnµŠšÎµŠµœœµŠÎµšµŠ„³ªnµœº˜Å¢Á œ„–š¸¸É ¨oªŠ´Ê„‡¸ ‹ª˜­¥¸Š…ŠÁ¨ªš—¸ÉŠ…´ œ¹ÊÁ„—‹· µ„„µÅ¨…ŠœÎʵ¥µšÎµ‡ªµ¤Á¥œÈ ‹ª˜­Š´Ê„‡¸ ‡ºÉŠž´µ„µ«Å¤nšÎµŠµœ·—ž„˜·Ÿªµ¤‡n¸ÊŤnÄžœnÅŠ˜´—µ„µ „—·ÅœÎʵ ¤¸¥—œÎʵÁ„—…· œ¹Ê1110650159CV.indd 28/11 216 PM

RAS-10JKCVP specifications

The Toshiba RAS-10JKCVP is a prominent air conditioning unit that combines cutting-edge technology, efficiency, and user-friendly features. Ideal for both residential and commercial spaces, this model represents Toshiba's commitment to providing reliable and high-performance climate control solutions.

One of the standout characteristics of the RAS-10JKCVP is its inverter technology. This system allows the compressor to adjust its speed continuously based on the current temperature of the room. As a result, the unit minimizes energy consumption by operating at a more efficient level, leading to lower electricity bills while maintaining consistent comfort. The inverter technology enhances cooling performance and significantly reduces temperature fluctuations, making the environment more pleasant.

In addition to energy efficiency, the Toshiba RAS-10JKCVP is designed with a strong focus on air quality. The unit is equipped with a multi-stage filtration system that effectively removes dust, allergens, and other harmful particles from the air. This feature is particularly beneficial for individuals with allergies or respiratory conditions, allowing for a healthier indoor atmosphere.

Another key feature of the RAS-10JKCVP is its whisper-quiet operation. The unit is engineered to run at low noise levels, enabling it to function without causing disruptions in your living or working space. This makes it an excellent choice for bedrooms, study areas, and offices where a peaceful environment is paramount.

The RAS-10JKCVP also boasts a user-friendly remote control, allowing users to easily adjust settings from a distance. Features such as programmable timers and temperature adjustments can be managed effortlessly, providing convenience and flexibility to users.

Aesthetically, the unit has a sleek and modern design that seamlessly integrates with various interior styles. Its compact size ensures that it fits well in different room layouts without taking up excessive space.

In conclusion, the Toshiba RAS-10JKCVP exemplifies advanced climate control technology, featuring inverter efficiency, superior air purification, quiet operation, and user-friendly controls. With its blend of performance and design, it stands out as a reliable solution for anyone seeking an effective air conditioning system.