Auto Restart Setting

This product is designed so that after a power failure, it can restart automatically in the same operating mode as before the power failure.

The product was shipped with Auto Restart function in the off position. Turn it on as required.

How to set the Auto Restart

1Press and hold the RESET button on the indoor unit for 3 seconds to set the operation (3 Pi sound and OPERATION lamp blink 5 time/sec for 5 seconds).

2Press and hold the RESET button on the indoor unit for 3 seconds to cancel the operation (3 Pi sound but OPERATION lamp does not blink).

In case of ON timer or OFF timer are set, AUTO RESTART OPERATION does not activate.

(Blue) (Orange)

3 seconds

33

1110650159_(31-38)_EN.indd 33

2/28/11 2:11 PM

Image 33
Contents ‡¼n¤º„µÄŠoµœ Contents Care and cleaning Picoion air cleaningPrecautions For safety Parts name When the front panel is openedAir inlet Front panel Open-close panel Air filterIndoor unit display Real time monitor displayTransmitting part Memory and recall user setting operationStart and Stop operation Kind of receiving tone CoverComfort sleep display Remote control when open coverPreparation before operation and checking Remote controllerIndoor unit Turn on the main power supplyWhen stops When starting automatic operation, select aWhen changing the temperature Temperature Automatic operationEconomic operation activated by the brightness search sensor Economic operation activated by active human search sensorFan only operation Cooling, Dry operation and Fan only operationWhen stopping When changing the temperatureDry OperationTo clean the air When stopping operationPicoion air purifier When changing the air direction, press FIX Air volume, Fix and SwingSetting for air flow Page 17 When swing, press Swing Every timeDirect air flow Comfort air flowWide air flow, spot air flow When adjusting the air direction slightlyEvery time when pressed within 3 seconds Timer operationTo cancel Comfort sleepDaily timer Timer on, Timer offFor timer on on For timer off Adjust the time to the starting stopping timeSet preferred operation Preset OperationECO Operation Energy SavingLimit maximum Current and Power consumption Indoor unit display Press Hi Power while holding the check buttonTo stop automatic cleaning during operation Automatic cleaningAutomatic cleaning operation More 2 timesRemote controller Care and cleaningCare of the outside casing Indoor unitFront panel Care and cleaning of the front panel and dust boxSlide the fixing levers 4 points of the dust box Dust BoxCare and cleaning of the air filter and brush unit How to careBrush unit How to remove Air filterFront and back side of the air filter When restarting for use Test run after care and cleaningPress again for approx second Close the front panel Check that it is closedIf the lamp blinks again, inspection and repair is required When the lamp of indoor unit blinksAuto Restart Setting Case of 2 air conditioners are installed near each other If the remote controller is not availableAt a time like this Concern about the operating noiseThese are not failures 111065015931-38EN.indd 28/11 211 PM These are not failures Condensation appears „µšÎµŠµœÂ´˜Ãœ¤´˜·Ážiµ¨¤Ã—¥˜Š ¨³„µÁžiµ¨¤ ¨¸„Á¨¸É¥Š ­µ´„µ—¼Â¨´„¬µÂ¨³šÎµ‡ªµ¤­³µ— ³­oµŠž³‹»¨Â¨³³¢„µ„µ«´œ˜µ¥ …o‡ª³ª´Š‡ÎµÁ˜ºœ …o‡ª³ª´Š˜´ªÁ‡ºÉŠ£µ¥Äœ ºÉœ·Ê­ªnœœoµ‹Â­—Š„µšÎµŠµœž‹‹ »´œ …ŠÁ‡ºÉŠž´µ„µ« ­ªnœ´­Šn­´ µ– ¼žÂ…ŠÁ­¸¥ŠÄœ …–³´­´µ–œš´ „¹¼žÂ„µšÎµŠµœš˜¸ÉoŠ„µ ¨³Á¸¥„čŠoµœ‡nµš˜¸ÉŠ´ÊŪo ž´»–£¼¤·º˜´ª˜Š´ÊÁª¨µ¤µ¥Á˜» ¸Ã¤š‡œÃš¨Á¤ºÉÁž—d µ‡„¸Ã¤š‡œÃš¨ ž—d¨nŠ‹nµ¥Å¢¢jµ¨´„ ˜´ªÁ‡ºÉŠ£µ¥Äœ¸Ê¸Ã¤š‡œÃš¨Åžš˜¸É´ª´­´ µ–·œ¢µÁ—œ˜´ªÁ‡ºÉŠ£µ¥Äœ ³¥³…Š„µ´ ¨³­Šn­´ µ–¤ºÉ˜oŠ„µÁ·É¤„µšÎµŠµœÄœÃ¤—´˜Ãœ¤´˜·ÄoÁ¨º„ a „µšÎµŠµœÄœÃ¤—´˜Ãœ¤´˜·¤ºÉ¥»—„µšÎµŠµœ ¤ºÉ˜oŠ„µÁž¨¸É¥œÂž¨Š³—´»–£¼¤·¥¨³Á¸¥—…Š„µšÎµŠµœÄœÃ¤—´˜Ãœ¤´˜· ¤ºÉÁ­¸¥Š žd€žd€ —Š…´ ¹Êœ ¤—šÎµ‡ªµ¤Á¥œÈ ä—¨—‡ªµ¤œºÊ ¨³Ã¤—¡´—¨¤Á¡¸¥Š¥nµŠÁ—¸¥ª…œ¹Ê šÎµÄoµ„µ«­³µ—×¥ ³¢„µ„µ«œ…–³ž´µ„µ« Šoµœ³ž´µ„µ«Äœ…–³ „—ž»i¤ ³¢„µ„µ«šÎµŠµœ ¥—„» µšÎµŠµœ…Š³¢„µ„µ« „—ž»i¤¤ºÉ˜oŠ„µÁž¨¸É¥œ‡nµ³—´ÂŠ¨¤ „— FAN ˜n¨³‡´ÊŠš„—ž¸É »i¤ ³—´ÂŠ¨¤Â¨³š·«šµŠ¨¤¤ºÉ˜oŠ„µÁž¨¸É¥œš·«šµŠ¨¤ „— FIX „µž´š·«šµŠ¨¤ œoµ 17žiµ¨¤Ã—¥˜Š „µÁžiµ¨¤ÂÁ¥Èœ­µ¥šnµœ­µ¤µ™Á¨º„¼žÂ„µÁžiµ¨¤ÂÁ¥œÈ­µ¥ „³‹µ¥¨¤Á¥ÈœÂ¨³Ážiµ¨¤ÁŒ¡µ³‹—»¨³Ážiµ¨¤Ã—¥˜Š º Ážiµ¨¤Â¨¸„Á¨¸É¥Š ‹µ„ ¤ºÉ˜oŠ„µž´š·«šµŠ¨¤Á¨È„œo¥Comfort sleep „µ˜Š´ÊÁª¨µ„µ˜Š´ÊÁª¨µ­µ´Îš„»Ç ª´œ „µ˜Š´ÊÁª¨µÁž—d, „µ˜Š´ÊÁª¨µž—d„µ˜Š‡´Ê nµ„µšÎµŠµœš¸ÉœºÉ  „µšÎµŠµœÄœÃ¤— ECO „µž³¥´—¡¨´ŠŠµœ„µ‹Îµ„—„´ ³Â­Å¢¢jµÂ¨³´˜µ„µÄo¡¨´ŠŠµœ­Š¼­—» „—ž»i¤ Check ‡oµŠÅªoץčoª´­—ž»¨µ¥Â¨¤ „—ž»i¤ Hi Power ×¥š„—ž¸É »i¤ Check ‡oµŠÅªo„µšÎµ‡ªµ¤­³µ—´˜Ãœ¤´˜· „µšÎµŠµœ…ŠÃ¤—šÎµ‡ªµ¤­³µ—´˜Ãœ¤´˜·„¨nŠÁ„È œi» „µ—¼Â¨´„¬µÂ¨³šÎµ‡ªµ¤­³µ— „µ—¼Â¨´„¬µ£µ¥œ„˜´ªÁ‡ºÉŠ˜´ªÁ‡ºÉŠ£µ¥Äœ ¸Ã¤š‡œÃš¨ œoµ„µ„Á‡ºÉŠž´µ„µ« „µ—¼Â¨Â¨³šÎµ‡ªµ¤­³µ—œoµ„µ„Á‡ºÉŠž´µ„µ«„„´ ¨nŠÁ„È œi»„¨nŠÁ„È œi» „µ™—„„µž³„ „µšÎµ‡ªµ¤­³µ— „µ—¼Â¨´„¬µ „µ—¼Â¨´„¬µÂ¨³šÎµ‡ªµ¤­³µ—Ÿœ„n Šµ„µ«Â¨³ÂžŠ¨´Š‹µ„šÎµ‡ªµ¤­³µ— Äo—εÁœœ„· µ š—­„µšÎµŠµœ¨´Š„µšÎµ‡ªµ¤­³µ— œoµ„µ™— Ÿœ„n Šµ„µ«—oµœœoµÂ¨³—oµœ¨´Š…ŠÂŸœ„n Šµ„µ« ¤µ¥Á˜» ¤n‡ªÄ­oµŽ„´¢„ ÁœºÉŠ‹µ„µ‹šÎµÄo„µšÎµŠµœŸ—ž„˜· ·ž—dœoµ„µ„Á‡ºÉŠž´µ„µ« ˜ª‹—¼¸„‡´ÊŠªnµž—d¨oª „—ž»i¤ ¸„‡´ÊŠœµœž³¤µ– 1 ª·œµš¸„—ž»i¤ Check œ¸Ã¤š‡oµŠÅªoœµœ„ªnµ 10 ª·œµš¸ ˜ª‹­Å¢Á˜ºœœœoµ‹Â­—Š„µšÎµŠµœ…ŠÁ‡ºÉŠž´µ„µ«¤ºÉÅ¢œ˜´ªÁ‡ºÉŠ£µ¥Äœ„³¡· žo¨µ¥—œ·­„—ž»i¤ Check Á¡ºÉž´¸Ã¤š‡œÃš¨Á…oµ­Án¼Žrª·­Ã¤—„—ž»i¤ Temp „µ˜Š„´Ê µÁ·É¤šÎµŠµœÄ¤n×¥´˜Ãœ¤´˜· œ„–š¸¸ÉŤn¤¸¸Ã¤š‡œÃš¨ œ„–¸—´Š˜nÅžœ¸Êœ„–š¸¸É¤¸„µ˜—˜· Š´ÊÁ‡ºÉŠž´µ„µ« 2 Á‡ºÉŠÅªoÄ„¨o„œ´ „¸É¥ª„´Á­¥¸Šš¸ÉÁ„—…· œ¹ÊÄœ³ªnµŠšÎµŠµœ¨oª œµŠÎµšµŠ„³ªnµœº˜Å¢Á œ„–š¸¸ÉŠ´Ê„‡¸ ‹ª˜­¥¸Š…ŠÁ¨ªš—¸ÉŠ…´ œ¹ÊÁ„—‹· µ„„µÅ¨…ŠœÎʵ¥µšÎµ‡ªµ¤Á¥œÈ ‡ºÉŠž´µ„µ«Å¤nšÎµŠµœ ·—ž„˜·Ÿªµ¤‡n¸ÊŤnÄžœnÅŠ˜´—µ„µ‹ª˜­Š´Ê„‡¸ ¤¸¥—œÎʵÁ„—…· œ¹Ê „—·ÅœÎʵ1110650159CV.indd 28/11 216 PM

RAS-10JKCVP specifications

The Toshiba RAS-10JKCVP is a prominent air conditioning unit that combines cutting-edge technology, efficiency, and user-friendly features. Ideal for both residential and commercial spaces, this model represents Toshiba's commitment to providing reliable and high-performance climate control solutions.

One of the standout characteristics of the RAS-10JKCVP is its inverter technology. This system allows the compressor to adjust its speed continuously based on the current temperature of the room. As a result, the unit minimizes energy consumption by operating at a more efficient level, leading to lower electricity bills while maintaining consistent comfort. The inverter technology enhances cooling performance and significantly reduces temperature fluctuations, making the environment more pleasant.

In addition to energy efficiency, the Toshiba RAS-10JKCVP is designed with a strong focus on air quality. The unit is equipped with a multi-stage filtration system that effectively removes dust, allergens, and other harmful particles from the air. This feature is particularly beneficial for individuals with allergies or respiratory conditions, allowing for a healthier indoor atmosphere.

Another key feature of the RAS-10JKCVP is its whisper-quiet operation. The unit is engineered to run at low noise levels, enabling it to function without causing disruptions in your living or working space. This makes it an excellent choice for bedrooms, study areas, and offices where a peaceful environment is paramount.

The RAS-10JKCVP also boasts a user-friendly remote control, allowing users to easily adjust settings from a distance. Features such as programmable timers and temperature adjustments can be managed effortlessly, providing convenience and flexibility to users.

Aesthetically, the unit has a sleek and modern design that seamlessly integrates with various interior styles. Its compact size ensures that it fits well in different room layouts without taking up excessive space.

In conclusion, the Toshiba RAS-10JKCVP exemplifies advanced climate control technology, featuring inverter efficiency, superior air purification, quiet operation, and user-friendly controls. With its blend of performance and design, it stands out as a reliable solution for anyone seeking an effective air conditioning system.