York YZH024 THRU 060 warranty Heating Performance Data High CFM 2-STAGE Operation

Page 21

 

 

 

 

 

 

 

 

 

 

345094-YTG-D-0108

 

 

 

 

 

 

HEATING PERFORMANCE DATA - HIGH CFM 2-STAGE OPERATION

 

 

 

 

 

OUTDOOR UNIT MODEL NO.

YZH02411

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INDOOR COIL MODEL NO.

FC/MC/PC48D + MV12D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIR TEMP.

AIR TEMP.

 

 

 

 

 

ID CFM

 

 

 

 

 

ENTERING

ENTERING

 

 

 

 

 

 

 

 

 

 

 

 

 

750

 

 

850

 

 

950

 

OUTDOOR

INDOOR

 

 

 

 

 

 

 

 

 

 

 

MBTUH

 

KW

C.O.P.

MBTUH

KW

C.O.P.

MBTUH

 

KW

C.O.P.

UNIT

COIL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60

31.6

 

1.7

5.4

32.0

1.7

5.6

32.4

 

1.6

5.9

60

 

 

 

 

 

 

 

 

 

 

 

 

70

30.9

 

1.9

4.8

31.4

1.8

5.0

31.9

 

1.8

5.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80

30.2

 

2.0

4.4

30.7

2.0

4.6

31.3

 

1.9

4.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60

26.8

 

1.6

4.8

27.0

1.6

5.0

27.2

 

1.5

5.2

47

 

 

 

 

 

 

 

 

 

 

 

 

70

26.4

 

1.8

4.3

26.6

1.7

4.5

26.8

 

1.7

4.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80

25.9

 

1.9

3.9

26.1

1.9

4.1

26.3

 

1.8

4.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60

24.4

 

1.6

4.5

24.5

1.5

4.7

24.6

 

1.5

4.9

40

 

 

 

 

 

 

 

 

 

 

 

 

70

23.9

 

1.7

4.1

24.1

1.7

4.2

24.3

 

1.6

4.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80

23.5

 

1.9

3.7

23.7

1.8

3.8

23.9

 

1.8

3.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60

20.7

 

1.5

4.1

20.9

1.5

4.2

21.0

 

1.4

4.3

30

 

 

 

 

 

 

 

 

 

 

 

 

70

20.5

 

1.6

3.7

20.7

1.6

3.8

20.8

 

1.6

3.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80

20.4

 

1.8

3.3

20.5

1.7

3.4

20.6

 

1.7

3.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60

16.6

 

1.4

3.5

16.7

1.4

3.6

16.8

 

1.3

3.7

17

 

 

 

 

 

 

 

 

 

 

 

 

70

16.6

 

1.5

3.2

16.6

1.5

3.3

16.7

 

1.5

3.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80

16.5

 

1.7

2.9

16.6

1.6

3.0

16.6

 

1.6

3.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60

14.8

 

1.3

3.2

14.8

1.3

3.3

14.8

 

1.3

3.4

10

 

 

 

 

 

 

 

 

 

 

 

 

70

14.7

 

1.5

2.9

14.7

1.5

3.0

14.8

 

1.4

3.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80

14.6

 

1.6

2.7

14.7

1.6

2.7

14.8

 

1.6

2.8

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.

Multipliers for determining the performance with other indoor section.

NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.

HIGH CFM

 

 

 

 

 

 

 

 

 

Air Handler

Coil

MBH

KW

COP

AV36

-

1.00

0.99

1.01

MV12B

FC/MC43B

1.00

1.00

1.00

MV12D

FC/MC60D

1.00

1.00

1.00

Variable Speed

Coil

T.C.

S.C.

KW

Furnace

 

 

 

 

P(C,V)9*B12

FC/MC/PC43B

1.00

0.98

1.02

Unitary Products Group

21

Image 21
Contents Warranty FeaturesDescription Model Physical and Electrical DataUnitary Products Group Seer HP with MV Variable Speed Cooling Capacity With Air Handler CoilsCooling Capacity With Variable Speed Furnaces 33.0 23.4 16.3O 13.30 46.5 27.2 Heating Capacity With Air HandlerHeating Capacity With Variable Speed Furnaces 780 26.4 PC,V8*C20 985 36.0 PC,V9*D20 Sound Power Ratings AccessoriesColor Grilles Choice of Several Color Coil Grilles to Compliment ANY HomeOutdoor Unit Model no Cooling Performance Data LOW CFM 1-STAGE OperationIndoor Coil Model no FC/MC/PC48D + MV12D LOW CFMHigh CFM Cooling Performance Data High CFM 2-STAGE OperationFC/MC62D + MV12D Indoor Coil Model no1148 1248 1348 YZH04811 1470 1570 1670 YZH06011 AV/SV60C MV20DC FC/MC60D MBH COP Heating Performance Data LOW CFM 1-STAGE OperationHeating Performance Data High CFM 2-STAGE Operation 759 809 859 1088 1188 1288 973 1023 1073 1423 1523 1623 AV/SV60 MV20D 1621 1721 1821 Unitary 5005 Norman Products York Group Drive 73069