York YZH024 THRU 060 warranty 1088 1188 1288

Page 23

 

 

 

 

 

 

 

 

 

 

345094-YTG-D-0108

 

 

 

 

 

 

HEATING PERFORMANCE DATA - HIGH CFM 2-STAGE OPERATION

 

 

 

 

 

OUTDOOR UNIT MODEL NO.

YZH03611

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INDOOR COIL MODEL NO.

FC/MC62D + MV12D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIR TEMP.

AIR TEMP.

 

 

 

 

 

ID CFM

 

 

 

 

 

ENTERING

ENTERING

 

 

 

 

 

 

 

 

 

 

 

 

 

1088

 

 

1188

 

 

1288

 

OUTDOOR

INDOOR

 

 

 

 

 

 

 

 

 

 

 

MBTUH

 

KW

C.O.P.

MBTUH

KW

C.O.P.

MBTUH

 

KW

C.O.P.

UNIT

COIL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60

48.8

 

2.5

5.7

49.1

2.5

5.9

49.5

 

2.4

6.1

60

 

 

 

 

 

 

 

 

 

 

 

 

70

47.7

 

2.8

5.0

48.0

2.7

5.1

48.3

 

2.6

5.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80

46.5

 

3.1

4.4

46.8

3.0

4.6

47.1

 

2.9

4.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60

39.9

 

2.4

4.9

40.0

2.3

5.1

40.1

 

2.2

5.3

47

 

 

 

 

 

 

 

 

 

 

 

 

70

39.3

 

2.6

4.3

39.4

2.6

4.5

39.5

 

2.5

4.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80

38.6

 

2.9

3.9

38.7

2.8

4.0

38.9

 

2.8

4.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60

35.6

 

2.3

4.6

35.8

2.2

4.7

35.9

 

2.2

4.9

40

 

 

 

 

 

 

 

 

 

 

 

 

70

35.0

 

2.5

4.0

35.1

2.5

4.1

35.3

 

2.4

4.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80

34.3

 

2.8

3.6

34.5

2.7

3.7

34.7

 

2.7

3.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60

29.7

 

2.2

4.0

29.9

2.1

4.1

30.0

 

2.1

4.3

30

 

 

 

 

 

 

 

 

 

 

 

 

70

29.2

 

2.4

3.5

29.4

2.4

3.6

29.6

 

2.3

3.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80

28.7

 

2.7

3.2

28.9

2.6

3.2

29.1

 

2.6

3.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60

22.6

 

2.0

3.3

22.8

2.0

3.4

22.9

 

1.9

3.5

17

 

 

 

 

 

 

 

 

 

 

 

 

70

22.4

 

2.2

2.9

22.5

2.2

3.0

22.7

 

2.2

3.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80

22.2

 

2.5

2.6

22.3

2.4

2.7

22.4

 

2.4

2.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60

19.3

 

1.9

3.0

19.4

1.9

3.0

19.5

 

1.9

3.1

10

 

 

 

 

 

 

 

 

 

 

 

 

70

19.3

 

2.1

2.6

19.3

2.1

2.7

19.3

 

2.1

2.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80

19.2

 

2.4

2.4

19.2

2.3

2.4

19.2

 

2.3

2.4

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.

Multipliers for determining the performance with other indoor sections.

NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.

HIGH CFM

 

 

 

 

 

 

 

 

 

Air Handler

Coil

MBH

KW

COP

AV36

-

1.00

0.98

1.02

AV/SV48

-

1.00

1.00

1.00

MV16C

FC/MC43C

1.00

1.00

1.00

MV16C

FC/MC48C

1.00

1.00

1.00

MV12D

FC/MC48D

1.00

1.00

1.00

MV12D

FC/MC60D

1.00

1.00

1.00

Variable Speed

Coil

T.C.

S.C.

KW

Furnace

 

 

 

 

P(C,V)8*B16

FC/MC/PC43B

1.00

0.97

1.03

P(C,V)8*C16

FC/MC/PC43C

1.00

0.98

1.02

P(C,V)8*C20

FC/MC/PC43C

1.00

0.98

1.02

P(C,V)9*B12

FC/MC/PC43B

1.00

0.96

1.04

P(C,V)9*C16

FC/MC/PC43C

1.00

0.97

1.03

P(C,V)9*C20

FC/MC/PC43C

1.00

0.97

1.03

P(C,V)8*C16

FC/MC/PC48C

1.00

1.00

1.00

P(C,V)8*C20

FC/MC/PC48C

1.00

1.00

1.00

P(C,V)9*C16

FC/MC/PC48C

1.00

0.98

1.02

P(C,V)9*C20

FC/MC/PC48C

1.00

0.98

1.02

P(C,V)9*D20

FC/MC/PC48D

1.00

0.98

1.02

P(C,V)8*C16

FC/PC60C

1.00

1.00

1.00

P(C,V)8*C20

FC/PC60C

1.00

1.00

1.00

P(C,V)9*C16

FC/PC60C

1.00

0.98

1.02

P(C,V)9*C20

FC/PC60C

1.00

0.98

1.02

P(C,V)9*D20

FC/MC/PC60D

1.00

0.98

1.02

P(C,V)8*C20

FC/MC62D

1.00

1.00

1.00

P(C,V)9*C20

FC/MC62D

1.00

0.98

1.02

P(C,V)9*D20

FC/MC62D

1.00

0.98

1.02

P(C,V)8*C16

HC42

1.00

0.98

1.02

P(C,V)8*C20

HC42

1.00

1.00

1.00

P(C,V)9*C16

HC42

1.00

0.97

1.03

P(C,V)9*C20

HC42

1.00

0.97

1.03

Unitary Products Group

23

Image 23
Contents Description WarrantyFeatures Model Physical and Electrical DataUnitary Products Group Seer HP with MV Variable Speed Cooling Capacity With Air Handler CoilsCooling Capacity With Variable Speed Furnaces 33.0 23.4 16.3O 13.30 46.5 27.2 Heating Capacity With Air HandlerHeating Capacity With Variable Speed Furnaces 780 26.4 PC,V8*C20 985 36.0 PC,V9*D20 Choice of Several Color Coil Grilles to Compliment ANY Home AccessoriesSound Power Ratings Color GrillesLOW CFM Cooling Performance Data LOW CFM 1-STAGE OperationOutdoor Unit Model no Indoor Coil Model no FC/MC/PC48D + MV12DHigh CFM Cooling Performance Data High CFM 2-STAGE OperationFC/MC62D + MV12D Indoor Coil Model no1148 1248 1348 YZH04811 1470 1570 1670 YZH06011 AV/SV60C MV20DC FC/MC60D MBH COP Heating Performance Data LOW CFM 1-STAGE OperationHeating Performance Data High CFM 2-STAGE Operation 759 809 859 1088 1188 1288 973 1023 1073 1423 1523 1623 AV/SV60 MV20D 1621 1721 1821 Unitary 5005 Norman Products York Group Drive 73069