York YZH024 THRU 060 warranty YZH06011

Page 18

345094-YTG-D-0108

COOLING PERFORMANCE DATA - LOW CFM 1-STAGE OPERATION

OUTDOOR UNIT MODEL NO.

YZH06011

 

 

 

 

 

 

 

 

 

 

 

 

 

INDOOR COIL MODEL NO.

FC/MC62D + MV20D

 

 

 

 

 

 

 

 

 

 

 

CONDENSER

ID CFM

 

 

1125

 

 

 

 

1175

 

 

 

 

1225

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENTERING AIR

ID DB (°F)

80

80

75

80

80

80

80

75

80

80

80

80

75

80

80

TEMPERATURE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ID WB (°F)

57

62

62

67

72

57

62

62

67

72

57

62

62

67

72

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

40.8

44.0

43.6

48.6

53.8

41.5

44.4

44.1

49.2

54.3

42.3

44.8

44.7

49.8

54.9

65

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

40.8

37.2

31.3

31.5

25.9

41.5

38.0

32.0

32.1

26.3

42.3

38.9

32.6

32.7

26.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

2.0

2.0

2.0

2.0

2.0

2.0

2.0

2.0

2.0

2.0

2.0

2.0

2.0

2.0

2.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

39.3

42.0

41.7

46.5

51.4

40.0

42.4

42.2

47.0

51.9

40.8

42.8

42.7

47.5

52.5

75

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

39.3

36.4

30.5

30.6

24.9

40.0

37.3

31.2

31.2

25.3

40.8

38.2

31.8

31.8

25.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

2.3

2.3

2.3

2.3

2.3

2.3

2.3

2.3

2.3

2.3

2.3

2.3

2.3

2.3

2.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

37.9

39.9

39.7

44.3

49.1

38.5

40.4

40.2

44.8

49.6

39.2

40.8

40.8

45.3

50.0

85

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

37.9

35.6

29.7

29.8

23.8

38.5

36.6

30.4

30.4

24.3

39.2

37.5

31.1

31.0

24.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

36.4

37.9

37.8

42.2

46.7

37.0

38.4

38.3

42.6

47.2

37.6

38.9

38.8

43.0

47.6

95

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

36.4

34.9

28.9

28.9

22.8

37.0

35.8

29.6

29.5

23.2

37.6

36.8

30.4

30.2

23.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

3.1

3.0

3.1

3.0

3.0

3.1

3.0

3.0

3.0

3.0

3.1

3.0

3.0

3.0

3.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

34.4

35.1

35.0

39.0

43.7

34.9

35.7

35.4

39.5

44.1

35.4

36.3

35.9

39.9

44.5

105

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

34.4

33.1

27.8

27.7

21.6

34.9

34.0

28.5

28.3

22.1

35.4

34.9

29.2

29.0

22.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

3.5

3.5

3.5

3.5

3.5

3.5

3.5

3.5

3.5

3.5

3.5

3.5

3.5

3.5

3.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

32.4

32.3

32.3

36.0

40.7

32.8

33.1

32.7

36.4

41.1

33.3

33.8

33.0

36.8

41.4

115

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

32.4

31.3

26.7

26.5

20.5

32.8

32.2

27.4

27.2

20.9

33.3

33.1

28.0

27.8

21.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

30.4

29.6

29.6

33.0

37.7

30.7

30.4

29.9

33.4

38.0

31.1

31.3

30.2

33.8

38.4

125

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

30.4

29.6

25.5

25.4

19.4

30.7

30.4

26.2

26.0

19.8

31.1

31.3

26.9

26.7

20.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

4.5

4.5

4.5

4.4

4.4

4.5

4.5

4.5

4.4

4.4

4.5

4.5

4.5

4.4

4.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.

Multipliers for determining the performance with other indoor sections.

NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.

NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.

LOW CFM

 

 

 

 

 

 

 

 

 

Air Handler

Coil

T.C.

S.C.

KW

AV/SV60

-

0.99

0.97

0.98

MV20D

FC/MC60D

0.96

0.87

1.09

Variable Speed

Coil

T.C.

S.C.

KW

Furnace

 

 

 

 

P(C,V)8*C20

FC/PC60C

0.98

0.96

0.96

P(C,V)9*C20

FC/PC60C

0.96

0.94

0.95

P(C,V)9*D20

FC/MC/PC60D

0.95

0.92

0.95

P(C,V)8*C20

FC/MC62D

0.98

0.97

0.97

P(C,V)9*C20

FC/MC62D

0.98

0.95

0.96

P(C,V)9*D20

FC/MC62D

0.96

0.93

0.95

18

Unitary Products Group

Image 18
Contents Warranty FeaturesDescription Physical and Electrical Data ModelUnitary Products Group Cooling Capacity With Air Handler Coils Seer HP with MV Variable SpeedCooling Capacity With Variable Speed Furnaces 33.0 23.4 16.3O 13.30 Heating Capacity With Air Handler 46.5 27.2Heating Capacity With Variable Speed Furnaces 780 26.4 PC,V8*C20 985 36.0 PC,V9*D20 Color Grilles AccessoriesSound Power Ratings Choice of Several Color Coil Grilles to Compliment ANY HomeIndoor Coil Model no FC/MC/PC48D + MV12D Cooling Performance Data LOW CFM 1-STAGE OperationOutdoor Unit Model no LOW CFMCooling Performance Data High CFM 2-STAGE Operation High CFMIndoor Coil Model no FC/MC62D + MV12D1148 1248 1348 YZH04811 1470 1570 1670 YZH06011 AV/SV60C MV20DC FC/MC60D Heating Performance Data LOW CFM 1-STAGE Operation MBH COPHeating Performance Data High CFM 2-STAGE Operation 759 809 859 1088 1188 1288 973 1023 1073 1423 1523 1623 AV/SV60 MV20D 1621 1721 1821 Unitary 5005 Norman Products York Group Drive 73069