York TG8S, TGLS warranty Cabinet and Duct Dimensions, Ratings & Physical / Electrical Data, Afue

Page 2

363657-YTG-C-0708

LEFT SIDE

28.5”

29.5”

.5” 24.38”

B

.5” 20”

SUPPLY END

Vent Connection

 

FRONT

 

 

 

 

 

 

 

 

Electrical

Outlet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Entry

 

 

 

 

 

 

 

 

 

 

Electrical

 

 

 

 

 

 

 

 

Vent

 

 

 

 

 

 

 

 

Connection

Entry

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outlet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas Pipe

 

Gas Pipe

 

 

 

 

 

 

 

 

Entry

 

 

 

 

 

 

 

 

 

Entry

 

 

 

 

 

 

33”

 

Thermostat

 

 

 

 

 

 

 

 

Thermostat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wiring

 

Wiring

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4” Diameter

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vent Connection

 

 

 

 

 

 

 

 

 

 

 

 

 

Outlet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RIGHT SIDE

23”

14”

1.5” 1”

.5”

.5”

24.25”

RETURN END

Cabinet and Duct Dimensions

 

Nominal

Cabinet

 

Cabinet Dimensions (Inches)

 

Approximate

Models

 

 

Operating Weights

CFM (m3/min)

Size

 

 

 

 

 

 

A

 

B

 

C

Lbs

 

 

 

 

 

TG(8,L)S040A08MP11

800

A

14 1/2

 

13 3/8

 

10.3

89

TG(8,L)S060A10MP11

1000

A

14 1/2

 

13 3/8

 

10.3

91

TG(8,L)S060A12MP11

1200

A

14 1/2

 

13 3/8

 

10.3

94

TG(8,L)S080B12MP11

1200

B

17 1/2

 

16 3/8

 

11.8

103

TG(8,L)S080C16MP11

1600

C

21

 

19 7/8

 

13.6

114

TG(8,L)S080C22MP11

2200

C

21

 

19 7/8

 

13.6

119

TG(8,L)S100B12MP11

1200

B

17 1/2

 

16 3/8

 

11.8

108

TG(8,L)S100C16MP11

1600

C

21

 

19 7/8

 

13.6

118

TG(8,L)S100C20MP11

2000

C

21

 

19 7/8

 

13.6

122

TG(8,L)S120C16MP11

1600

C

21

 

19 7/8

 

15.8

123

TG(8,L)S120C20MP11

2000

C

21

 

19 7/8

 

15.8

129

TG(8,L)S130D20MP11

2000

D

24 1/2

 

23 3/8

 

17.5

135

Ratings & Physical / Electrical Data

Models

Input

Output

AFUE

Air Temp.

Max. Outlet

Blower

Blower

Max

Total Unit

Min. wire Size

 

 

Rise

Air Temp

 

 

Size

Over-Current

Amps

(awg) @ 75 ft

 

MBH

MBH

 

°F

°F

HP

Amps

Protect

one way

 

 

 

 

TG(8,L)S040A08MP11

40

32

80.0

25-55

155

1/5

2.1

9 x 8

10

4.5

14

TG(8,L)S060A10MP11

60

48

80.0

25-55

155

1/3

3.8

9 x 8

10

6.0

14

TG(8,L)S060A12MP11

60

48

80.0

30-60

160

1/3

4.8

11 x 8

10

7.0

14

TG(8,L)S080B12MP11

80

64

80.0

35-65

165

1/3

4.8

11 x 8

10

7.5

14

TG(8,L)S080C16MP11

80

64

80.0

25-55

155

1/2

7.5

11 x 10

15

10.0

14

TG(8,L)S080C22MP11

80

64

80.0

25-55

155

1

14.5

11 x 11

20

16.0

12

TG(8,L)S100B12MP11

100

80

80.0

40-70

170

1/3

4.8

9 x 8

10

7.5

14

TG(8,L)S100C16MP11

100

80

80.0

35-65

165

1/2

7.5

11 x 10

15

10.0

14

TG(8,L)S100C20MP11

100

80

80.0

25-55

155

1

14.5

11 x 11

20

17.0

12

TG(8,L)S120C16MP11

120

96

80.0

40-70

170

1/2

7.5

11 x 10

15

10.0

14

TG(8,L)S120C20MP11

120

96

80.0

30-60

160

1

14.5

11 x 11

20

17.0

12

TG(8,L)S130D20MP11

130

104

80.0

35-65

165

1

14.5

11 x 11

20

17.0

12

Nominal external static pressure is 0.50” w.c. at furnace outlet ahead of cooling coils.

Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.

Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.

2

Johnson Controls Unitary Products

Image 2
Contents Description WarrantyFeatures 40 130 MBH InputAfue Cabinet and Duct DimensionsRatings & Physical / Electrical Data Recommended Filter Sizes Horizontal Sidewall VentingFilter Performance CFMAccessories Propane LP Conversion KITBottom Airflow Data Scfm Johnson Controls Unitary Products York Drive Norman, OK

TGLS, TG8S specifications

The York TG8S and TGLS are two advanced commercial air conditioning units designed for high performance and efficiency, making them ideal for a variety of HVAC (heating, ventilation, and air conditioning) applications. These units exemplify York's commitment to delivering reliable and eco-friendly cooling solutions tailored to meet the diverse needs of modern buildings.

The York TG8S is known for its exceptional energy efficiency, achieving SEER (Seasonal Energy Efficiency Ratio) ratings that often exceed industry standards. This allows businesses to significantly reduce their energy consumption and operational costs while ensuring optimal indoor comfort. The unit features a robust design that can withstand harsh environmental conditions, making it suitable for both indoor and outdoor installations.

One of the standout features of the TG8S is its variable-speed compressor technology. This allows the system to adjust its cooling output based on the current demand, leading to improved temperature control and reduced energy usage. Additionally, the unit is equipped with advanced microprocessor controls that provide precise monitoring and customization of system performance, ensuring consistent comfort year-round.

On the other hand, the York TGLS series is specifically designed for larger commercial applications, such as office complexes and shopping centers. It is recognized for its modular design, which allows for easy installation and scalability. The TGLS units can be combined to create a system tailored to larger spaces, ensuring efficient temperature management throughout the entire facility.

Both the TG8S and TGLS units employ advanced refrigerants with low global warming potential (GWP), aligning with current environmental regulations and initiatives aimed at reducing climate impact. The units are built with durable materials that not only enhance longevity but also contribute to their resistance against corrosion and wear.

Another noteworthy characteristic is their remarkably low noise levels, ensuring a comfortable environment without disruptive sounds. This is particularly important for commercial settings where maintaining a pleasant atmosphere is essential for customers and employees alike.

In conclusion, the York TG8S and TGLS units represent the forefront of HVAC technology, combining energy efficiency, advanced control systems, and environmentally responsible features. Their ability to adapt to varying cooling needs makes them an excellent choice for businesses looking to invest in sustainable cooling solutions while enhancing overall comfort.