York Discover Essential Electrical Specifications for Air Conditioner Models

Page 20

036-21044-003-A-0304

TABLE 10: ELECTRICAL DATA 7-1/2 TON

 

 

 

OD

Supply Blower

Pwr Exh

 

 

 

Min. Circuit

MCA

Max Fuse2

Max Fuse Size

 

 

 

 

 

 

w/Power

w/Power

 

Compressors

Fan

 

 

 

Ampacity

 

Motor FLA

Motor

Electric

 

 

Exhaust

Size (Amps)

Exhaust

 

 

 

Motors

Actual

Heater

(Amps)

Voltage1

 

 

 

 

 

Heater

(Amps)

 

 

(Amps)

 

 

 

 

 

 

kW

Amps

 

 

 

 

 

RLA

LRA

FLA

1.5 HP

2 HP

FLA

Model No.

 

 

1.5 HP

2 HP

1.5 HP

2 HP

1.5 HP

2 HP

1.5 HP

2 HP

 

(1.1

(1.5

 

 

 

(1.1

(1.5

(1.1

(1.5

(1.1

(1.5

(1.1

(1.5

 

ea.

ea.

ea.

 

 

 

 

kW)

kW)

 

 

 

 

kW)

kW)

kW)

kW)

kW)

kW)

kW)

kW)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

None

-

-

25.2

26.1

27.4

28.3

30

30

35

35

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2TP04520950

5.6

8.5

25.2

26.1

27.4

28.3

30

30

35

35

380

8.3

62

1.1

4.3

5.2

2.2

 

 

 

 

 

 

 

 

 

 

 

2TP04521850

11.3

17.2

26.8

28.0

29.6

30.7

30

30

35

35

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2TP04522450

15.0

22.8

33.9

35.0

36.6

37.7

35

35

40

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2TP04523650

21.3

32.4

45.8

47.0

48.6

49.7

50

50

50

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

None

-

-

25.2

26.1

27.4

28.3

30

30

35

35

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2TP04520950

6.7

9.3

25.2

26.1

27.4

28.3

30

30

35

35

415

8.3

62

1.1

4.3

5.2

2.2

 

 

 

 

 

 

 

 

 

 

 

2TP04521850

13.5

18.8

28.9

30.0

31.6

32.7

30

30

35

35

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2TP04522450

17.9

24.9

36.5

37.6

39.3

40.4

40

40

40

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2TP04523650

25.4

35.3

49.5

50.7

52.3

53.4

50

60

60

60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.Unit voltage limitations: minimum utilization 342 volts, maximum utilization 457 volts.

2.Maximum HACR breaker of the same amp size is acceptable.

TABLE 11: ELECTRICAL DATA 10 TON

 

 

 

OD

Supply Blower

Pwr Exh

 

 

 

Min. Circuit

MCA

Max Fuse2

Max Fuse Size

 

 

 

 

 

 

w/Power

w/Power

 

Compressors

Fan

 

 

 

Ampacity

 

Motor FLA

Motor

Electric

 

 

Exhaust

Size (Amps)

Exhaust

 

 

 

Motors

Actual

Heater

(Amps)

Voltage1

 

 

 

 

 

Heater

(Amps)

 

 

(Amps)

 

 

 

 

 

 

kW

Amps

 

 

 

 

 

 

 

 

 

 

 

Model No.

 

 

 

 

 

 

 

 

 

RLA

LRA

FLA

2 HP

4 HP

 

 

 

2 HP

4 HP

2 HP

4 HP

2 HP

4 HP

2 HP

4 HP

 

FLA

 

 

 

(1.5

(3

 

ea.

ea.

ea.

(1.5 kW)

(3 kW)

 

 

 

(1.5 kW)

(3 kW)

(1.5 kW)

(3 kW)

(1.5 kW)

(3 kW)

 

 

 

 

 

kW)

kW)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

None

-

-

29.0

31.3

31.2

33.5

35

40

40

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2TP04521850

11.3

17.2

29.0

31.3

31.2

33.5

35

40

40

40

380

9.6

79

1.1

5.2

7.5

2.2

 

 

 

 

 

 

 

 

 

 

 

2TP04522450

15.0

22.8

35.0

37.9

37.7

40.6

35

40

40

45

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2TP04523650

21.3

32.4

47.0

49.8

49.7

52.6

50

50

50

60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2TP04525450

33.8

51.4

70.7

73.6

73.4

76.3

80

80

80

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

None

-

-

29.0

31.3

31.2

33.5

35

40

40

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2TP04521850

13.5

18.8

30.0

32.9

32.7

35.6

35

40

40

40

415

9.6

79

1.1

5.2

7.5

2.2

 

 

 

 

 

 

 

 

 

 

 

2TP04522450

17.9

24.9

37.6

40.5

40.4

43.3

40

45

45

45

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2TP04523650

25.4

35.3

50.7

53.5

53.4

56.3

60

60

60

60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2TP04525450

40.4

56.2

76.8

79.6

79.5

82.4

80

80

80

90

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.Unit voltage limitations: minimum utilization 342 volts, maximum utilization 457 volts.

2.Maximum HACR breaker of the same amp size is acceptable.

TABLE 12: ELECTRICAL DATA 12-1/2 TON

 

 

 

 

 

 

 

 

 

 

Min. Cir-

MCA

Max

Max Fuse

 

 

 

OD

Supply Air

 

 

 

 

 

Size

 

Compressors

Pwr Exh

 

 

 

cuit

w/Power

Fuse2

 

Fan

Blower

Electric

 

 

w/Power

 

Motor

Actual

Heater

Ampacity

Exhaust

Size

Voltage1

 

 

Motors

Motor FLA

Heater

Exhaust

 

 

 

 

kW

Amps

(Amps)

(Amps)

(Amps)

 

 

 

 

 

 

 

Model No.

 

 

 

 

 

(Amps)

 

RLA

LRA

FLA

4 HP (3 kW)

FLA

 

 

 

4 HP

4 HP

4 HP

4 HP

 

ea.

ea.

ea.

 

 

 

(3 kW)

(3 kW)

(3 kW)

(3 kW)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

None

-

-

36.7

38.9

45

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2TP04521850

11.3

17.2

36.7

38.9

45

50

380

12.0

91

1.1

7.5

2.2

 

 

 

 

 

 

 

 

 

2TP04522450

15.0

22.8

37.9

40.6

45

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2TP04523650

21.3

32.4

49.8

52.6

50

60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2TP04525450

33.8

51.4

73.6

76.3

80

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

None

-

-

36.7

38.9

45

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2TP04521850

13.5

18.8

36.7

38.9

45

50

415

12.0

101

1.1

7.5

2.2

 

 

 

 

 

 

 

 

 

2TP04522450

17.9

24.9

40.5

43.3

45

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2TP04523650

25.4

35.3

53.5

56.3

60

60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2TP04525450

40.4

56.2

79.6

82.4

80

90

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.Unit voltage limitations: minimum utilization 342 volts, maximum utilization 457 volts.

2.Maximum HACR breaker of the same amp size is acceptable.

20

Unitary Products

Image 20
Contents Technical Table of Contents Predator Component Location Environmentally Aware For036-21044-003-A-0304 Factory Installed Options Field Installed Accessories Low Limit / Compressor Lockout Kit ½ 12½ Ton Predator Model Number Nomenclature Nomenclature Additional OPTIONSì Johnson UNT Controller, DFS, APS & Phase Monitor Technicoat Condenser Coil, Coil Guard, & Dirty Filter Switch Physical Data Component Models 090 120 150Capacity Ratings Imperial Capacity Ratings MetricCooling Capacity 7-1/2 TON Unit Imperial Cooling Capacity 26.4 KW Unit Metric M3/sCooling Capacity 10 TON Unit Imperial 35004000 4500Cooling Capacity 35.1 KW Unit Metric Cap.1 Input2 Return Dry Bulb CCooling Capacity 12-1/2 TON Unit Imperial 43755625 6250Cooling Capacity 43.9 KW Unit Metric Electrical Data 12-1/2 TON Electrical Data 7-1/2 TONElectrical Data 10 TON Turns Open 100 149 199 249Blower Performance 10 TON Standard Motor Side Duct Imperial Blower Performance 10 TON Standard Motor Side Duct Metric100 149 199 249 299 349 399 100 149 199 249 299 349100 149 199 249 299 349 399 448 498 548 Blower Performance 10 TON Optional Motor Side Duct ImperialBlower Performance 10 TON Optional Motor Side Duct Metric 100 149 199 249 299 349 399 448 498 Blower Performance 12-1/2 TON Side Duct ImperialBlower Performance 12-1/2 TON Side Duct Metric Blower Performance 7-1/2 TON Standard Motor Downshot Metric Blower Performance 7-1/2 TON Optional Motor Downshot Metric Blower Performance 10 TON Standard Motor Downshot ImperialBlower Performance 10 TON Standard Motor Downshot Metric 100 149 199 249 299Blower Performance 10 TON Optional Motor Downshot Imperial Blower Performance 10 TON Optional Motor Downshot Metric100 149 199 249 299 349 399 448 Blower Performance 12-1/2 TON Downshot ImperialBlower Performance 12-1/2 TON Downshot Metric Additional Static Resistance Imperial Cooling Only1 Economizer2 Electric Heat KW2Additional Static Resistance Metric Electric Heat Minimum Supply AIR ImperialElectric Heat Minimum Supply AIR Metric 12.5Indoor Blower Specifications Point Load WeightUnit Weight Model Location lbs. kg 090Detail B Unit ClearancesDetail C Detail D RightPredator Roof Curb Dimensions Bottom Duct Openings from Above Cooling Unit with GAS Heat Wiring Diagram Cooling Unit WITH/WITHOUT Electric Heat Wiring Diagram Unitary 5005 Norman Products York Group Drive 73069

DM120, DM150 specifications

The York DM120 and DM150 are advanced rooftop packaged units designed for commercial applications, offering high efficiency, reliability, and user-friendly features. These models are part of York's extensive range of HVAC solutions, aimed at meeting diverse heating, ventilation, and air conditioning needs.

One prominent feature of both the DM120 and DM150 is their streamlined, compact design, which allows for easy installation and fits seamlessly onto rooftops. These units are engineered to maximize space while ensuring high performance. With their robust construction, they are built to withstand harsh weather conditions, ensuring longevity and durability.

The DM120 is designed to provide a cooling capacity of up to 12 tons, whereas the DM150 can reach up to 15 tons. Both models utilize environmentally friendly refrigerants, which contribute to reducing the overall carbon footprint. This makes them a sustainable choice for businesses looking to enhance their environmental responsibility.

In terms of efficiency, both units are equipped with high-efficiency scroll compressors that optimize energy usage, lowering operational costs. They also feature advanced heat exchanger designs that enhance heat transfer efficiency, ensuring consistent indoor comfort while minimizing energy consumption.

User-friendly controls are another hallmark of the York DM120 and DM150. They come with an intuitive interface that allows for easy adjustments and monitoring of system performance. Advanced controls support integration with building management systems, enabling remote monitoring and control for enhanced operational efficiency.

The DM120 and DM150 also prioritize indoor air quality. They incorporate advanced filtration systems that capture airborne particles and improve ventilation, contributing to healthier indoor environments. Furthermore, these models come with variable-speed fans that adjust airflow based on current conditions, optimizing comfort while reducing noise levels.

The models are also designed for serviceability, allowing technicians easy access to critical components for maintenance. This feature not only prolongs the lifespan of the units but also minimizes downtime, keeping commercial spaces comfortable and operational.

In summary, the York DM120 and DM150 units represent an ideal balance of efficiency, technology, and reliability, making them suitable for various commercial applications. Their robust features, commitment to sustainability, and focus on user convenience make them a valuable investment for businesses seeking to improve their HVAC systems.